Phone
13910499766
-
Address
Building 5, Guanghua Entrepreneurship Park, No. 18 Anningzhuang East Road, Haidian District, Beijing
Beijing Lijia United Technology Co., Ltd
13910499766
Building 5, Guanghua Entrepreneurship Park, No. 18 Anningzhuang East Road, Haidian District, Beijing

characteristic:
1. Developed in collaboration with the International Atomic Energy Agency (IAEA), and rigorously tested by the IAEA, the IAEA has over 50 devices with authoritative and reliable data
2. Measure 150 unknown samples per day for higher efficiency
3. High precision and accuracy
4. Field online continuous measurement can be conducted, providing a new way of isotope measurement
5. LGR Spectral Diagnostic Technology (SCI) can effectively correct sample data containing organic solvents, with a wider sample range among similar products
6. Positive and negative standard samples, complete consumables and accessories

Performance indicators:
◆ Repeatability/Precision - High precision mode (1 σ, 22 unknown samples/day):
Ensure accuracy: δ2H<0.2‰,δ17o <="" 0.03‰,17o-excess="" (20="" per="">0.2‰,δ17o><>
Typical accuracy: δ2H<0.15‰,δ17o <="" 0.02‰,17o-excess="" (15="" per="">0.15‰,δ17o><>
◆ Repeatability/Precision - High precision mode (1 σ, 110 unknown samples/day):
Ensure accuracy: δ2H<0.4‰,δ17o <="">0.4‰,δ17o><>
Typical accuracy: δ2H<0.3‰,δ17o <="">0.3‰,δ17o><>
Measurement speed:
800 injections per day
◆ Sample volume:
<1 μl="">1>
◆ Sample salinity:
<4% (when the sample salinity exceeds 4%>4%)
◆ Environmental temperature:
Sample temperature: 0~50 ℃
Working temperature: 0~45 ℃
◆ Output:
Digital (RS 232), Ethernet USB
◆ Electricity demand:
115/230 VAC, 50/60 Hz, 180 W (including pump)
Size and weight:
27.9 cm(H)x 96.5 cm(W)x 55.9 cm(D),40 kg
Performance testing: ![]() Measurement accuracy and precision superior to isotope ratio mass spectrometer
|
![]()
Linear and Range----Large scale isotope ratio measurement
|
Comparison analysis was conducted between LGR liquid water isotope analyzer and data from 5 different mass spectrometry laboratories. Fifty LWIA-24d analyzers were used to measure liquid water isotope standards (δ D: -79.00 ‰, δ 18O: -11.54 ‰), and the results verified the excellent performance of the analyzers (high accuracy, precision, and repeatability), R2>0.99999. |
The linearity and range of LWIA-24d were extensively tested, with a measurement range of -454.3 ‰ to+1701 ‰ for δ D and -58.62 ‰ to+266.8 ‰ for δ 18O, R2>0.99999. |
Optional attachments:
1. PAL LC xt: Automatic sampling system, including control software
2. 908-0008-9014: Manual Water Vapor Injection Attachment
3. Consumables: 1.2 μ l syringe, diaphragm, 2 ml sample cup, sample cup cap, sample cup cover film, 10 μ m filter, dry air tank, 8-mesh desiccant, negative standard sample (5 types), positive standard sample (4 types).
4. AWVCT-04: Atmospheric Water Vapor Cold Trap
After sales support: Provide lifelong technical support and after-sales service