M2 seriesIntelligent pressure gauge

The Meriam M2 series intelligent pressure gauge enables users of handheld digital pressure gauges to obtain high-precision measurement values. M2 meets the full range traceability accuracy of ± 0.025% required by the American Institute of Standards and Technology, is not affected by temperature, and has the lowest price. The pressure range from 3kPa to 200bar is available for selection.
The M2 pressure sensor can be used to measure gauge pressure (GL), composite pressure (Cl), differential pressure (DI/DN), absolute (Al), or vacuum pressure. This monitor can display eleven pressure units and also provide linear scale display for special user units. The differential pressure mode also provides the square root function of the flow function to display the flow rate in user-defined units.
Adjustable damping characteristics minimize the impact of pulsating voltage. The Min/Max function can capture extreme pulsation values, and the Hold function can hold the display interface at any target information point. Automatically record up to 240 readings of files for future reference.
Accuracy-
Accuracy:+0.05% FS or optional ± 0.025% FS, unaffected by stability from -5 ° C to+50 ° C.
authentication
Ex ia IIC T4
Level I, Group A, B, C, D, T4 in Zone 1
Engineering unit
Inches of water column (choose 4 ℃, 20 ℃), PSI, Millimeter mercury column, inch mercury column, millimeter pull, pull, kilopascal, kilogram/square centimeter, centimeter water column, user selectable scale.
Media compatibility:
DN: Non insulated differential sensor that is clean, dry, and free of corrosive gases.
Gauge pressure&absolute pressure: Insulation gauge/absolute pressure sensor for fluids compatible with 316L stainless steel, refer to Meriam M200-DI liquid/wet differential pressure type requirements
Pressure limit
When only applying pressure to the high-pressure side of the differential pressure unit, the measuring instrument and absolute pressure unit have twice the range; When pressure is applied to both sides of the sensor simultaneously, the static pressure is 10 bar (10.5 Kg/cm2).
leak test
Allow users to view the minimum/maximum pressure values and calculate the leakage rate of the pressure unit per minute. This feature makes the troubleshooting and pressure testing of the pneumatic system very convenient.
automatic recording
Record up to 240 readings (automatic or manual) to reduce paperwork and save on-site time. The saved readings can be accessed at any time.
Damping rate
The user can choose a time constant range of 0.1 to 25 seconds, with exponential decay
Minimum/maximum capture
The capture speed is equal to the selected damping rate.
On site recalibration
M2 series zeroing, range, and linearity can be recalibrated on site. Users can choose between a 1-point or 5-point calibration program. Enable users to calibrate their equipment on-site with precise reference objects.
Automatic shutdown
User shutdown option. Program for 10, 20, 30, 45, and 60 minutes.
Temperature specifications
| When stored: | -40 ℃ to 60 ℃ |
| During operation: | -Inherent Safety (IS) mode from 5 ℃ to 50 ℃ |
| -20 ℃ to 50 ℃ General Purpose (GP) Model |
technical specifications
base unit
400g (165x91x57mm) polycarbonate, permanently dissipative, anti-static protection.
keyboard
Sealing film type with 5 dome shaped contact buttons
display
5-digit significant digital LCD display (6mm high), adjustable contrast 2-line X16 alphanumeric characters with two-level backlighting, visible over range indication
power supply
Four AA batteries can be used continuously for over 100 hours.
Parts that come into contact with liquids:
DN: 316L stainless steel, brass, fluororubber
GI: 316L stainless steel
AI: 316L stainless steel
Connector
1/8 "NPT internal thread, 316L stainless steel
NIST traceable accuracy
Pressure:+0.05% FS standard, optional ± 0.025% FS (DN0010 is only ± 0.05% FS). The precision table includes all the effects of temperature on the specified operating range. Note: When calculating the accuracy of the "CI" type pressure sensor, use the measurement upper limit (URL) as the full range.
ordering information
Model and Description
M200- (indicating pressure range) - Intelligent pressure gauge
M201- (indicating pressure range) - Rotary gas flow meter tester (only applicable to DN0028 or DN0200 sensor range)
All models include
Red protective rubber sleeve
Four alkaline batteries
Paper version user manual
Pressure Range
| DN0010 | 0 to 3.000 kPa +/- 0.05% FSV – Full Scale Value | differential pressure |
| DN0028 | 0 to 7.0000 kPa +/- 0.05% FSV | differential pressure |
| DN0200 | 0 to 35.000 kPa +/- 0.05% FSV | differential pressure |
| DN0415 | 0 to 120.00 kPa +/- 0.05% FSV | differential pressure |
| DN2000 | 0 to 500.00 kPa +/- 0.05% FSV | differential pressure |
| GI0015 | 0 to 100.00 kPa +/- 0.05 % FSV | gauge pressure |
| GI0030 | 0 to 200.00 kPa +/- 0.05% FSV | gauge pressure |
| GI0050 | 0 to 350.00 kPa +/- 0.05% FSV | gauge pressure |
| GI0100 | 0 to 700.00 kPa +/- 0.05% FSV | gauge pressure |
| GI0300 | 0 to 2000.0 kPa +/- 0.05% FSV | gauge pressure |
| GI0500 | 0 to 3500 kPa +/- 0.05% FSV | gauge pressure |
| GI1000 | 0 to 7000.0 kPa +/- 0.05% FSV | gauge pressure |
| GI3000 | 0 to 20000 kPa +/- 0.05% FSV | gauge pressure |
| CI0015* | -100.00 to 100.00 kPa +/- 0.05% FSV | composite |
| CI0030* | -100 to 200.00 kPa +/- 0.05% FSV | composite |
| CI0050* | -100 to 350.00 kPa +/- 0.05% FSV | composite |
| CI0100* | -100 to 700.00 kPa +/- 0.05% FSV | composite |
| CI0300* | -100.0 to 2000.0 kPa +/- 0.05% FSV | composite |
| CI0500* | -100 to 3500 kPa +/- 0.05% FSV | composite |
| CI1000* | -100 to 7000.0 kPa +/- 0.05% FSV | composite |
| CI3000* | -100 to 20000 kPa +/- 0.05% FSV | composite |
| AI0017 | 0.05% FSV 0-17 PSIA (0-120.00 kPa A) | Absolute pressure |
| AI0038 | 0.05 % FSV 0-38 PSIA (0-300.00 kPa A) | Absolute pressure |
| AI0100 | 0.05% FSV 0-100 PSIA (0-700.00 kPa A) | Absolute pressure |
| AI1000 | 0.05% FSV 0-1000 PSIA (0-7000.0 kPa A) | Absolute pressure |
| *When calculating CI accuracy, use the upper range limit as the full range | ||
authentication
Ex ia IIC T4
DEMKO 06 ATEX 0615699 IP 40
Class I,Div.1 Groups A,B,C,D, T4
Intrinsically Safe, Exia
Class I, Zone 0, AEx ia IIC T4
Class I, Zone 0, Ex ia IIC T4
-5 C < Ta < +50 C
Options
| Z9P000107 | Hard Mobile Toolbox |
| Z9P000108 | Hard portable bag with vacuum pump |
| Z9P000109 | Hard portable bag with pressure pump |
| ZA34386 | Brass connector kit |
M200-DI Liquid/Wet Differential Pressure Application
The Meriam M200-DI handheld intelligent pressure gauge is capable of high-precision measurement of liquid/wet pressure differentials. M200-DI can also be applied to potentially corrosive/humid gases. The intrinsic safety mode achieves a traceable accuracy of ± 0.05% FS (± 0.025% FS optional) from the American Institute of Standards and Technology, and is not affected by temperature within the range of -5 ° C to 50 ° C. The precision meter is suitable for universal mode between -20 ° C and 50 ° C.