Welcome Customer !

Membership

Help

Shenzhen Yijie Instrument Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

M201 Rotary Gas Meter Tester

NegotiableUpdate on 06/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The M201 rotary gas meter detector has an accuracy of 0.1% FS (28 "water column range) or 0.05% FS (200" water column range). Compared with mechanical instruments or pressure gauges, it has better accuracy in low pressure drop range. The M201 rotary gas meter tester is very suitable for on-site use, and its accuracy is not affected by temperature within the calibrated range of 23 ℉ to 122 ℉. The temperature effect can cause serious accuracy errors in mechanical instruments, liquid pressure gauges, and some digital counters.

Product Details

M201 Rotary Gas Meter Tester

M201

The M201 rotary gas meter detector is specifically programmed to measure differential pressure and display the true average of these measurements. Users can control the measurement average time. This feature solves the problems of traffic surge and pulsation.

The M201 rotary gas meter detector has an accuracy of 0.1% FS (28 "water column range) or 0.05% FS (200" water column range). Compared with mechanical instruments or pressure gauges, it has better accuracy in low pressure drop range. The M201 rotary gas meter tester is very suitable for on-site use, and its accuracy is not affected by temperature within the calibrated range of 23 ℉ to 122 ℉. The temperature effect can cause serious accuracy errors in mechanical instruments, liquid pressure gauges, and some digital counters.

Digital display can eliminate parallax, and based on the instrument range, the resolution can reach 0.01 or 0.001 "water column. The minimum/maximum function allows users to see the maximum and minimum recorded pressures during testing. The instrument is portable and can be used to read manifolds as a whole. The M201 rotary gas meter tester can be safely used on pipelines with static pressures up to 150 PSIG.

accuracy-

DN0028:+ 0.1%FS 0-28“

DN0200:+ 0.05%FS 0-200“

Within the range of 23 ° to 122 ° F (-5 ° to+50 ° C), it is not affected by temperature.

Engineering unit

Inches of water column (choose 4 ℃, 20 ℃ or 60 ℉) PSI, Millimeter mercury, inch mercury, millibar, bar, kilopascal, kilogram/square centimeter, centimeter water column, user selectable scale.

Media compatibility:

DN: Non insulated sensor for clean, dry, non corrosive gases..

On site recalibration

M201 series zeroing, range and linearity can be recalibrated on site. Users can choose between a 1-point or 5-point calibration program. Enable users to calibrate their equipment on-site with precise reference objects.

Pressure limit

When only applying pressure to the high-pressure side of the differential pressure unit, it is twice the range; When pressure is applied to both sides of the sensor simultaneously, the static pressure is 150 PSI (10.5 Kg/cm2).

minimum/Maximum Collection

The collection speed is 10X per second.

operate

During the connection of the pressure gauge, push the reading valve to keep the high and low sides equal. Open M201 "ON" to obtain information "Press Hold to collect data. ”Press the "HOLD" key to start the test. The user confirms the testing time and presses the "HOLD" button again to end the test. The display screen will show the average pressure difference across the pressure gauge from the start to the end of the test. Press the "HOLD" button again to start a new test.

Automatic shutdown

User shutdown option. Program for 10, 20, 30, 45, 60 minutes and disable

technical specifications

base unit

14 oz (6.5 "X 3.6" X 2.25 ") polycarbonate, permanently dissipative, anti-static protection.

keyboard

Sealing film type with 5 dome shaped contact buttons

display

5-digit significant digital LCD display (0.25 "high), adjustable contrast 2-line X16 alphanumeric characters including backlighting.

power supply

Four No. 5 batteries can be used continuously for more than 100 hours.

Parts that come into contact with liquids:

DN: 316L stainless steel, brass, fluororubber

Connector

1/8 "NPT internal thread, 316L stainless steel

NISTTraceability accuracy

DN0028:+ 0.1%FS 0-28“

DN0200:+0.05% FS 0-200 "F.S. Refer to the" Pressure Range "table for the entire range

Temperature specifications

Storage temperature: -40 ℉ to 140 ℉ (-40 ℃ to 60 ℃)

Operating temperature: 23 ℉ to 122 ℉ (-5 ℃ to 50 ℃) I.S. model

-4 ℉ to 122 ℉ (-20 ℃ to 50 ℃) G.P. model

Pressure Range
DN0028

0-28” H2O

Differential pressure (+. 1% F.S.)
DN0200

0-200” H2O

Differential pressure (+. 05% F.S.)

authentication

Ex ia IIC T4

DEMKO 06 ATEX 0615699 IP 40

Class I,Div.1 Groups A,B,C,D, T4

Intrinsically Safe, Exia

Class I, Zone 0, AEx ia IIC T4

Class I, Zone 0, Ex

-5 C < Ta < +50 C

ordering information

Model and Description

M201- (indicating pressure range) - Rotary gas flow meter tester (only applicable to DN0028 or DN0200 sensor range)

All models include

Red protective rubber sleeve

Four No. 5 batteries

Paper version user manual

Ordering Options

Intrinsic safety certification

Z9P000107 Hard Mobile Toolbox
Z9P000108 Hard portable bag with vacuum pump
Z9P000109 Hard portable bag with pressure pump
A34386 Connector kit
A900016-90727 Peter plug adapter, Y8“
A900016-90733 Peter plug adapter, Y16”
Share to: