MXT-500 SimDist metal capillary column (stainless steel treated with Siltek technology)

NegotiableUpdate on 03/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

(Non polar stationary phase) • Sturdy stainless steel tube column treated with Siltek technology, meeting all separation indicators for high-temperature simulated distillation (such as extended ASTM method D2887) • MXT-1HT SimDist and MXT-1 SimDist stationary phases provide true polarity of polydimethylsiloxane • MXT-500 SimDist stationary phase is a carboborane siloxane polymer • Stable at 430 ° C

Product Details

MXT®-500 SimDistMetal capillary column(Siltek®Technically processed stainless steel

non-polar stationary phase
· pass throughSiltek®The sturdy stainless steel tube dedicated column for technical processing meets all separation indicators for high-temperature simulated distillation (such as extended)ASTMmethodD2887
·MXT®-1HT SimDistandMXT®-1 SimDistFixed phase provides truePolarity of polymethyl silicone
·MXT®-500 SimDistThe stationary phase is carborane siloxane polymer
·430 °CMaintain stability
Product Name:MXT-500 SimDist
Temp. Limits:-60 to 430°C
Length:6m
Internal Diameter:0.53mm
df (µm):0.15μm
Description:
· pass throughSiltek®The sturdy stainless steel tube dedicated column for technical processing meets all separation indicators for high-temperature simulated distillation (such as extended)ASTMmethodD2887
·MXT®-1HT SimDistandMXT®-1 SimDistFixed phase provides truePolarity of polymethyl silicone
·MXT®-500 SimDistThe stationary phase is carborane siloxane polymer
·430 °CMaintain stability
useSiltek®Made of stainless steel pipes that have undergone technical processingMXT®Pillars are the most heat-resistantGCColumn. just asASTMmethodD6352As summarized, high-temperature simulated distillation requires column capability430 °CThe high temperature. Even in430 °CAt high temperatures,MXT®-1HT SimDistandMXT®-500 SimDistPillars can also exhibit peak shapes and low losses. uniqueMXT®-1HT SimDistPolymethyl silicone polymer has the correct retention time/Boiling point curve.MXT®-500 SimDistThe carbon borosiloxane polymer has a slight variation in the calculated boiling range distribution of petroleum samples, including aromatic hydrocarbons.