Welcome Customer !

Membership

Help

Beijing Lijia United Technology Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Beijing Lijia United Technology Co., Ltd

  • E-mail

  • Phone

    13910499766

  • Address

    Building 5, Guanghua Entrepreneurship Park, No. 18 Anningzhuang East Road, Haidian District, Beijing

Contact Now

Methane/Nitrous Oxide Analyzer

NegotiableUpdate on 02/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Used for sample measurement at atmospheric background level, with higher accuracy while high-frequency sampling in Hz.
Product Details

甲烷/氧化亚氮分析仪

2013 In the year,LGR (currently under ABB Canada)A new device - methane - has been released/Nitrous oxide analyzer, capable of simultaneously measuring methaneAnd nitrous oxide(CH4N2OandH2O). This device is designed for sample measurement at the atmospheric background levelHzHaving higher accuracy while performing high-frequency sampling. Can meet various demanding usage requirements, including trace amountsGas monitoring, vorticity related flux measurement, and chamber flux measurement. be based onN2O/COExperience with analyzers, methane/The nitrous oxide analyzer is suitable for field use and is completely free from interference from other environmental gases. Adopting a brand new mid infrared excitationLight and detector components, no need for complicated liquid nitrogen refrigeration or water circulation refrigeration modes.
This analyzer usesLGRThe patented off-axis integrating cavity output spectrum(OA-ICOS)The technology (patent number: 6795190) is used for this purposeContinuous synchronous measurement of three gases. This analyzer is simple to use, low power consumption, and very suitable for field researchmeasureCH4andN2OThe ability to simplify sample analysis. Absorption spectroscopy analysis enables the instrument to perform water dilutionCorrection of effects and absorption baseline widening effects, while outputtingCH4 andN2ODry mole fraction without the need for later numbersAccording to processing or sample drying. In addition,LGRThe new extension range option can expand the range, in20 Double the atmosphereWithin the concentration range, it has unparalleled accuracy and linearity. Support manual injection measurement mode, enriching application methods.

characteristic:
Simultaneously meet the requirements of high-frequency output and high-precision measurement
Simultaneous measurement of all gases
Real time viewing of measured spectra
Direct output of dry mole fractions of methane and nitrous oxide
Support manual injection measurement mode
Wide linear range
No need for liquid nitrogen or water circulation refrigeration

Performance indicators:
repeatability/Accuracy(1σ,0.1sec /1 sec /100 sec

N2O0.6 ppb / 0.2 ppb/0.05 ppb (standard/EP type)

CH43 ppb / 1 ppb/ 0.25 ppb(Standard/EP type)

H2O500 ppm /150 ppm / 30 ppm(Standard/EP type)

The accuracy of portable instruments is twice that of standard instruments

The data rate is less than1 Need for fast streaming option in seconds (standard type)/EPType), not suitable for portable type

Drift(EPType,15 Minute average, standard temperature and pressure,24 Hour)
N2O2 ppb
CH45 ppb
H2O50 ppmOr reading1%The larger one shall prevail
Measurement speed:
0.01~10 Hz(Flow rate response <6 An external pump is required in seconds
Measurement range (under all technical specifications):
N2O0~10 ppm
CH40~100 ppm
Environmental conditions:
Sample temperature:-30~50
Operating temperature:5~35℃ (standard type)
0~45℃(EPType)
ambient humidity:0~100% RH, without condensation
Output:
Number(RS 232)Simulation, EthernetUSB
Electricity demand:
115/230 VAC50/60 Hz180 /350W (Standard type/ EPtype)
Size and weight:
22.2 cmHx 48.3 cmWx 80 cmD),36kg (Standard type)
48.9 cmHx 48.3 cmWx 80 cmD),68kg ( EPtype)
20.3 cmHx 50.8 cmWx 70 cmD),23kg (Portable type)

Ordering information:
Model number(Model):
GLA251-N2OM1(Standard type)
GLA351-N2OM1EPType)
GLA151-N2OM1(Portable)
Optional items:
1. 908-0003-9001/900216/8Road multiplexer
2. MC-100016 road/8Dao synchronous multiplexer
3. N920Vacuum pump (gas update time)1.2 Seconds)
4. N940Vacuum pump (gas update time)0.5 Seconds)
5. XDS-10Dry ScrollVacuum pump (gas update time)0.12 Seconds)
6. XDS-35iDry ScrollVacuum pump (gas update time)0.05 Seconds)
7. 904-0002Data collection software that can record and synchronize multiple devicesLGRAnalyzer andGPSAnemometer, etc
Data output by the device

After sales support: Provide lifelong technical support and after-sales service
manufacturer:ABB Canada