Pipeline leakage monitoring is an important industrial safety measure aimed at ensuring the safety of liquids or gases during transportation. This monitoring system detects potential leakage risks by real-time monitoring of parameters such as fluid pressure, temperature, and flow rate inside the pipeline, as well as changes in the surrounding environment. Once an abnormal situation is detected, the monitoring system will immediately issue an alarm in order to take corresponding emergency measures.
The importance of pipeline leak monitoring is self-evident. Firstly, leakage may lead to wastage of resources and decrease production efficiency. For example, the leakage of energy sources such as oil and natural gas can lead to significant economic losses. Secondly, leakage may lead to serious accidents such as fires and explosions, causing serious damage to personnel safety and equipment. In addition, leaks may also cause pollution to the environment and affect ecological balance. Therefore, effective pipeline leak monitoring is crucial for industries such as petroleum, chemical, and natural gas.
Pipeline leakage monitoring is an important means to ensure industrial production safety. By adopting advanced monitoring technology and management methods, enterprises can effectively prevent and respond to leakage risks, ensuring the smooth progress of the production process. With the continuous development of technology, future pipeline leak monitoring technology will become more intelligent and accurate, providing stronger guarantees for industrial safety.
Shanghai Chaohui has successfully developed a solution for pipeline leakage systems, which consists of intelligent leakage sensors, temperature and humidity sensors, liquid level sensors, signal collectors, and software analysis platforms. By analyzing the collected data, potential leakage risks can be identified, providing strong support for decision-makers. In addition, by continuously optimizing the performance and accuracy of the monitoring system, the safety performance of the pipeline can be further improved.


Solution for leak monitoring of thermal oil pipelines
Project Background
Second section of thermal oil pipeline. 80 meters and 160 meters. The temperature of the pipe wall is 50-80 degrees Celsius, and there is a brief accumulation of water on the ground. The entire section is monitored.

Installation diagram notes: Leakage transmitter (A1-A5), ground water accumulation transmitter (C), humidity transmitter (B)

Principle of Leakage Monitoring for Thermal Oil Pipeline
There is a slight leakage phenomenon in the thermal oil pipeline, and the liquid (oil) passes through the special material of the leakage transmitter, generating a strain conversion signal output. Based on the data signal, the platform identifies the location and status of the leaking pipeline. According to the project background, high-precision positioning adds temperature, humidity, and ground water accumulation recognition functions to prevent false alarms and more accurately monitor pipelines.
Leakage transmitter: The standard configuration for leakage transmitters is 5 meters. Each meter is a sensing device module. If a leakage alarm occurs, replace the sensing device module.

Product advantages
quick response
Pipeline leakage transmitters can monitor liquid (such as crude oil or other liquids) pipelines in real-time, day and night, minute and second. If there is a perforation leak or water accumulation in the pipeline, the sensor will immediately detect it and give an alarm in a timely manner.
high-precision positioning
Pipeline leakage transmitters have high-precision positioning capabilities, which can accurately locate the leakage point when a leak occurs, making it convenient for engineering personnel to quickly find the problem and repair it.
high sensitivity
Pipeline leak monitoring sensors have high sensitivity and can be more sensitive to small leaks, thereby detecting potential risks in advance.
Comprehensive pipeline inspection
A sensor station is set up every 5 meters or longer along the route to record faults and detect multiple leaks in the pipeline. Each pipeline leakage transmitter is 5 meters long, and 2 ground water accumulation transmitters are installed in each tunnel.
install
Easy installation, modular assembly, fixed point position, adjustable device installation.
data analysis
Pipeline leakage monitoring system, real-time data collection, random query of historical data, report export, model matching, and printing. Compare and verify whether there are any missing items between the main table and sub table data.

System package diagram


system software
The software display, alarm frequency, curve analysis, data reporting and other functions can be customized according to on-site needs.