manufacturer: Feimet Corporation of the United States Introduction: The D P T-910 online natural gas dew point analyzer is a field dew point analyzer produced using the most advanced nano microporous metal oxide film dew point sensor. Combined with the unique sample gas processing system of Feimet Company, it can quickly and accurately measure the water dew point of natural gas in the dew point temperature range of -110 ℃ to+20 ℃.
Main Features: Explosion proof certification, suitable for hazardous environments 4-20mA current output and RS422 output On site installation, installation of 2-inch pipe bracket The instrument box comes with a large observation window for easy on-site viewing by users Integrated sample gas pretreatment system
Difficulties in measuring moisture content in natural gas: Most of the components in natural gas are methane, but pollutants usually exist in one or several states, such as triethylene glycol, ethanol, natural gas liquids, H2S, and various particulate pollutants. What pollutants are contained depends on the natural gas source. The pressure range of natural gas may be from 50 bar to 100 bar. These working conditions make it difficult for dew point analyzers to operate. In most cases, complex cleaning steps such as water washing are required for natural gas to ensure the proper functioning of sensors, which increases the workload of instrument maintenance personnel.
The optimal solution for measuring natural gas moisture content: Nanotechnology sensor: Fimet's dew point analyzer adopts patented nano microporous metal oxide film technology, which has fast response from dry to wet or from wet to dry, and has high accuracy and repeatability. Nanotechnology has changed the critical properties of materials, so Fimet's sensors can accurately, repetitively, and quickly measure results in the range of -110 to+20 ° C (dp).
Technical Specifications:
|
Dew point sensor
|
Measurement range: -110 ℃~+20 ℃ Accuracy: ± 2 ℃ Gas flow rate:>1 L/M
|
|
circuit
|
3 automatic detection - adaptive power mode:
1) 90-260VAC 47-440Hz or 2) 12-24VDC 10VA or 3) 4-20mA
Power mode 1 or 2 has the following output functions:
a) Isolated RS-422 b) 4-20mA support for Hart protocol c) 3 alarm relays -3A, 250VAC
|
|
machine
|
The air inlet and outlet are all 1/4 "card sleeve interfaces, and all pipe and valve components are made of stainless steel material
Shell: Engineering fiberglass instrument box, IP66&IP68 protection level
FM/CSA 防爆认证: Class I, Div I, Groups B, C And D Class II, III, Div 1, Groups E, F And G
ATEX防爆认证: ATEX 2 GD, Exd I & IIC; IECEx, Exd I & IIC
|
|
Operating temperature
|
-20~+60℃
|
Application fieldPetrochemicals, petrochemicals, natural gas.
|