Overview

The objective standard for perspective observation using a transmission fog imager is that when light scatters through transparent products, it will produce a cloudy or blurry appearance. The objective measurement standard of the transmission haze analyzer i can quantify people's feelings: ■ Full transmittance ■ Transmission haze ■ Perspective clarity. The transmission haze analyzer i only needs one measurement to obtain all the parameters that control transparency.

Product Details

The new BYK-4775 transmission fog imager i has been officially released

Transmission fogging instrument i

Objective standards for perspective observation

When light scatters through transparent products, it can produce a cloudy or blurry appearance. The objective measurement standard of the transmission fog shadow instrument i can quantify people's feelings:

■ Full transmittance

■ Transmission fog shadow

■ Perspective clarity

The transmission fog imager i only needs one measurement to obtain all the parameters that control transparency.

Global applicability

The international standard measurement method for integrating fog shadow and total transmittance quality control in one instrument:

■ ASTM D 1003- C Light Source and A Light Source

Non compensatory law

ISO 13468-D65 light source

Compensation Law

The transmission fog imager i can display all measurement results simultaneously - including all preset custom specifications.

Reliable and precise

The transmission fog imager i with the most advanced optical and LED technology brings * high-performance performance:

Reference beam, self diagnosis, and closed optical path

LED light source ensures long-term stable measurement results for several years: bulb life is guaranteed for ten years!

Automatic long-term calibration - easy to operate and reliable

Ensure excellent measurement repeatability and inter instrument measurement accuracy.

Intelligent and Swift

The new touch screen design allows for easy and intuitive completion of any task.

Large color touch screen display

Icon based menu function selection

■ Dedicated measurement button

The foot switch can be operated without the need for manual operation

Open and flexible

The open measurement chamber allows you to freely analyze samples of any size:

Open design suitable for small or large samples

Quickly replace and locate the sample

Not affected by the surrounding ambient light

Multi functional sample holder suitable for measuring films and sheets

Taber Wear Test Stand and Test Tube for Liquid Measurement

Customized brackets for customers can be easily installed

Horizontal or vertical placement

Conveniently placing samples in any position brings high flexibility to your experiments.

Airborne analysis

For efficient work management, measurement data can be directly analyzed on the transmission fog imager i and saved to the instrument's project file:

■ Large memory capacity (can store 5000 readings)

■ It has complete statistical functions, including mean, minimum/maximum value, and standard deviation

■ Different tolerance values can be entered for different product requirements, and the qualified/unqualified analysis results can be displayed by color

Professional Connection

Data transmission can be carried out through various methods to support the daily work of your laboratory:

Directly transfer data to a personal computer through a USB port

■ Connect directly to your office network via LAN and conduct further analysis in your laboratory information management system (LIMS)

Save data to USB drive

Smart Lab Haze - Data Analysis Software

The smart lab haze software is capable of performing any job you need, generating sample data tables for a single measurement series and trend analysis reports over a period of time - anything is possible.

Set user-defined product specifications in standard management and establish boundaries for product qualification/nonconformity assessment.

■ Measure your products online and display quality reports immediately: data tables with statistical results and line charts with colored indicators of qualified/unqualified

Manage your laboratory work in project documents: use trend reports to reflect the stability of production processes

■ Transfer product specifications and project files to the transmission fog imager i for daily work management

standard

ASTM D 1003, D 1044

ISO 13468, 14782

ordering information

Model name

4775 Transmission fogging instrument i

Basic configuration:

Host with sample holder

Clarity calibration standard board

Traceable certificate

Foot switch and power cord

USB cable and LAN cable

Smart lab haze software CD with key disk (2 licenses)

Operation Manual

train

Extended warranty: refer to the relevant sections of technical services

Free: 1 instrument maintenance service provided during the warranty period

Attention: To understand the software key fees required for installing smart lab haze software on more than two computers, please consult with your local BYK Gardner representative.

System requirements:

Operating System: Windows 7 SP1 or 8.1

Micorsoft ® . NET Framework 4

Hardware: Recommended Core2 Duo, 2.2GHz, i7, Or equivalent configuration

Memory: 4GB RAM, recommended 8GM hard drive

Hard disk available space: Zui Less 300MB

monitor: 1280x1024 resolution or higher

disc drive: CD-ROM or DVD drive

Port: Available USB or LAN ports

Technical indicators

Light sourceCIE-C, CIE-A (ASTM D1003)

CIE-D65 (ISO 13468, ISO 14782)

Spectral responseCIE spectral function y

Light path0 °/Scattering

Measurement areaDiameter 18 mm (0.7 in)

Sample mouthDiameter 25.4 mm (1.0 in)

Measurement range0 - 100 %

Repeatability± 0.1 units (standard deviation)

Reproducibility± 0.4 units (standard deviation)

Memory capacity5000 numerical values

InterfaceLAN, USB2.0, Comes with a front USB port for connecting to a USB flash drive

Power Supply115V/230V, with built-in adapter

Working temperature+10 ~ 40 °C (+50 ~ 104 °F)

Storage temperature0 ~ 50 °C (+32 ~ 122 °F)

Volume (width x height x depth)62 x 33 x 22 cm (24 x 13 x 9 in)

Weight18 kg (40 lbs)


train

BYK Gardner provides you with more than just an instrument, we will help you learn how to use a transmission fogger and data analysis. The half day training course includes training on the operation of the Transmission Fog Shadow Instrument I and Smart Lab Haze software.

Multi purpose sample holder suitable for various special needs

Easy to replace with various sample holders

Special film holder suitable for measuring ultra-thin films

Ordering Information Optional Parts and Spare Parts

Model name

4784 Thin film bracket for 4775, suitable for very thin films

4785 Taber fog shadow bracket, used for 4775 to evaluate wear resistance

4786 Transmission cell bracket, used for measuring liquids in 4775

6180 Liquid optical cell, 2.5mm path length 2.5mm, cell width 50mm

6182 Liquid optical cell, 5 mm path length 5.0 mm, cell width 50 mm

6183 Liquid optical cell, 10mm path length 10mm, cell width 50mm

6189 Liquid optical cell, 20mm path length 20mm, cell width 50mm

4865 BYK software smart lab haze for professional document analysis and processing

The measurement of fog shadow is used to determine the wear resistance of transparent materials, and the fog shadow bracket attachment can be used to place the wear area in the measurement beam.

The optical cell and its bracket can be used for the best measurement of liquids



Ordering Information Optional Parts and Spare Parts

Model name

4776 Clarity calibration board, used as a clarity standard board for 4775 replacement, with certificate

4777 Clarity reference standard board, clarity testing standard board for 4775 inspection, with certificate

4790 Fog Shadow Test Standard 1, used for 4775 fog shadow of approximately 1%, for testing purposes, with certificate

4791 Fog Shadow Test Standard 5, used for 4775 fog shadow of approximately 5%, for testing purposes, with certificate

4792 Fog Shadow Test Standard 10, used for 4775 fog shadow of approximately 10%, for testing purposes, with certificate

4793 Fog Shadow Test Standard 20, used for 4775 fog shadow of approximately 20%, for testing purposes, with certificate

4794 Fog Shadow Test Standard 30, for 4775 fog shadow approximately 30%, for testing purposes, with certificate

4795 One set of fog shadow testing standards, used for 4775. One set of 5 fog shadow standards is placed in a hard box with a certificate

4778 Transmittance standard 10, used for 4775 full transmittance of approximately 10%, for testing purposes, with certificate

4779 Transmittance standard 30, used for 4775 full transmittance of approximately 30%, for testing purposes, with certificate

4780 Transmittance standard 50, used for 4775 full transmittance of approximately 50%, for testing purposes, with certificate

4781 Transmittance standard 70, used for 4775 full transmittance of approximately 70%, for testing purposes, with certificate

4782 Transmittance standard 90, used for 4775 with a total transmittance of approximately 90%, for testing purposes, with certificate

4783 One set of transmission standards, used for 4775. One set of 5 transmission standards is placed in a hard box with a certificate