Welcome Customer !

Membership

Help

Beijing Lijia United Technology Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Beijing Lijia United Technology Co., Ltd

  • E-mail

  • Phone

    13910499766

  • Address

    Building 5, Guanghua Entrepreneurship Park, No. 18 Anningzhuang East Road, Haidian District, Beijing

Contact Now

Nitrogen dioxide analyzer (NO2)

NegotiableUpdate on 02/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
High precision and fast collection of NO2 gas concentration, simple and easy to use, very suitable for field and laboratory applications.
Product Details

二氧化氮分析仪 (NO2)

LGR (currently under ABB Canada)ofNO2The analyzer adoptsLGRThe patented off-axis integrating cavity output spectrum(OA-ICOS)Technology (Patent No. 6795190) for measuring in air samplesNO2The concentration.NO2The advantage of an analyzer is that it can collect data with high precision and speedNO2Gas concentration.NO2The analyzer is simple and easy to use, making it very suitable for field and laboratory applications. The analyzer has a built-in computer(LinuxThe operating system can automatically store data on the hard drive and transmit data through interfaces such as analog, digital, and network. In addition,NO2The analyzer integrates an online air dryer to automatically remove moisture, thereby eliminating the dilution effect of moisture. At the same time, it uses metal oxidation technology to automatically provide chemical zeroing without the need for specialized preparation of zero gas.
characteristic:
1. high-precision:0.05 ppb (1σ60second)
2. Collection speed:1Hz
3. Low power consumption:100W
4. No need for zero gas, automatic zero adjustment
5. Easy to use
6. Full range linearity
Performance indicators:
Repeatability/Accuracy(1Seconds)
50 ppt
Measurement speed (cavity emptying time):
Standard built-in pump:10Seconds;
Optional external vacuum pump configuration:1second
Drift(EPType,15Minute average, standard temperature and pressure,24Hour)
50 ppt
Measurement range (under all technical specifications):
0.01~1000 ppb
Optional range
0~3000 ppb
Environmental conditions:
Sample temperature:0~50
Operating temperature:5~45
ambient humidity:0~100% RH, without condensation
Output:
Number(RS 232)Simulation, EthernetUSB
Electricity demand:
115/230 VAC50/60 Hz100 W(Standard type)/ 150 WEPType)
Size and weight
Standard typeplatform type25.4 cmHx 96.5 cmWx 35.6 cmD),27 kg
Standard type, rack mounted:22.2 cmHx 48.3 cmWx 61 cmD),27 kg
EPType, rack mounted:35.6 cmHx 48.3 cmWx 61 cmD),40 kg
Ordering information:
Model number(Model):
GLA211-NO2(Standard type, rack mounted)
GLA311-NO2EPType, rack mounted)
Optional items:
1. MIU-1616Road multiplexer
2. MIU-88Road multiplexer
manufacturer:
ABB Canada