WN-10 Air Pollution Online Detection System
1、 Brief Introduction to Online Air Pollution Detection System:
WN-10The air pollution online detection system is our company's latest air quality detector, which can be flexibly configured to includeCO2An intelligent composite gas detector with up to four types of sensors, suitable for gas detection in garbage dumps, industrial hygiene, and other detection fields. It is currently the only product on the market that can detect oxygen, hydrogen sulfide, methane, combustible gases, and conventional toxic gases, while also using infrared sensors simultaneously(NDIR)detectionCO2The pump suction composite gas detector provides a comprehensive detection method for various toxic and harmful gases.Simultaneously capable of detecting temperature and humidityThe instrument is equipped with data storage256Group, throughUSBInterface, can connect to a computer.Having a very clearcolor touch screenSound and light alarm prompt, with built-in pump.
2、 Characteristics of the Air Pollution Online Detection System Instrument:
OptionalO2TheCHTheLELThePIDTheCO2And choose any plug-in "smart" toxic gas sensor:COTheH2STheSO2TheNOTheNO2 Cl2TheHCNTheNH3ThePH3
1. Detect gases in the air, as well as the temperature and humidity of the environment.
2. The instrument comes with built-in data storage, which can store data up to256group. WithUSBdata interface
3Equipped with a built-in suction pump, it can handle multiple tasks
4HavingLarge color touch screenEasy and fast operation.
5The instrument displays ppm andmg/m3twoplantDisplay data that can be automatically converted.
6Self check the display, battery, sensors, and sound and light alarm functions when turned on or needed.
3、 Working principle of air pollution online detection instrument:
1. Adopting the most advanced technologyPLCTechnology, stable and reliable operation of system instruments
2. Equipped with a sampling and dust removal system, as well as semiconductor refrigeration technology, it can reduce the gas temperature in the incineration flue gas
3.
4. Additional accessories can also be addedPM2.5andPM10probe
5. Equipped with data collection and remote communication functions,
6. have485Signal output interface.
4Technical Specifications:
Using several conventional sensor configurations as examples, actual purchasing users can determine the type of gas being detected by themselves
(1) methaneLEL(CH4)Measurement range0-100%Resolution:1%.
(2) oxygen(O2)Measurement range0-30%Resolution:0.1%
(3) carbon dioxide(CO2)Measurement range0-20000ppmResolution:10ppm
(4) hydrogen sulfide(H2S)Measurement range0-500ppmResolution:1ppm
(5) Sensor lifespan: What is the lifespan of the carbon dioxide sensor7Year, the lifespan of other sensors is30month
(6) Battery working time: Approximately continuous operation 200About an hour, with an additional charger included
(7) Display: Large screen LCD display
(8) Operating Temperature-10-45℃ Working humidity:5-90%R
★ Simultaneously display concentration:ppmThemg/m3,Temperature and humidity.
★ Color touch screen display with time and date memory function.
★ It has data query function and data storage256Group, there isUSBInterface.
It has remote data transmission function, automatic sampling and dust removal system, and regular blowback and cleaning function.
Configurable sensors:
Main sensor technical indicators of composite gas detector
|
Technical Specifications: l You can freely choose infrared sensors or electrochemical sensors,Form a composite gas analyzer. |
range |
essence degree |
minimum reading |
response time |
|
|
Formaldehyde detector |
0-10.00ppm |
<±5%(F.S) |
0.01ppm |
≤25second |
|
|
oxygen(O2) |
0-30%Vol |
<±5%(F.S) |
0.1%Vol |
≤15second |
|
|
Ozone detector |
0-20ppm |
<±5%(F.S) |
0.01 ppm |
≤30second |
|
|
flammable gas(EX) |
0-100%LEL |
<±5%(F.S) |
1%LEL |
≤5second |
|
|
carbon monoxide(CO) |
0-100ppm |
<±5%(F.S) |
0.1ppm |
≤25second |
|
|
hydrogen sulfide(H2S) |
0-100.0ppm |
<±5%(F.S) |
0.1ppm |
≤30second |
|
|
sulfur dioxide(SO2) |
0-100ppm |
<±5%(F.S) |
0.1ppm |
≤30second |
|
|
nitric oxide(NO) |
0-250ppm |
<±5%(F.S) |
1ppm |
≤60second |
|
|
nitrogen dioxide(NO2) |
0-20ppm |
<±5%(F.S) |
0.1ppm |
≤25second |
|
|
chlorine gas(CL2) |
0-20ppm |
<±5%(F.S) |
0.1ppm |
≤30second |
|
|
ammonia(NH3) |
0-100ppm |
<±5%(F.S) |
1ppm |
≤50second |
|
|
hydrogen(H2) |
0-1000ppm |
<±5%(F.S) |
1ppm |
≤60second |
|
|
Hydrogen cyanide(HCN) |
0-50ppm |
<±5%(F.S) |
0.1ppm |
≤200second |
|
|
hydrogen chloride(HCL) |
0-20ppm |
<±5%(F.S) |
0.1ppm |
≤60second |
|
|
phosphine(PH3) |
0-5-1000 ppm |
<±5%(F.S) |
0.01/1ppm |
≤25second |
4、 Instrument configuration for online detection system of air pollution:
(1)instrument main unit(Including built-in battery) a (2)charger a
(3)Sampling rod a set (4)Sampling hose a
(5)Aluminum alloy carrying case a (6)Operation manual and certificate of conformity a copy