Orion Star T920 Redox Potentiometer and Kit

NegotiableUpdate on 03/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Orion Star T920 redox potentiometric titrator is specifically designed for redox potentiometric titration, including sulfite/SO2 and reducing sugars in fruit juice and wine, ascorbic acid (vitamin C) and peroxide value in food, dissolved oxygen in wastewater (Winkler titration method), and organic matter in soil. Titration techniques include isostatic titration and pre-set mV endpoint titration, which are suitable for various sample analyses. Combining the titrator option with any of our Orion redox potential electrodes, or choosing our pre configured titrator and electrode kit, can result in a more cost-effective titration solution.
Product Details

**Reproducible results: Through the automatic titration workflow, the same set parameters and calculations can be used each time to perform analysis
• Quick time setting: Use multiple methods to set and save electrode, titrant, and titration parameters only once
• Laboratory throughput has improved: titration has started and instruments are running in unmanned mode
• Reduce costs and downtime: Easy to replace titrator components can minimize maintenance downtime, while durable electrodes can reduce owner costs
• * * Record the test results: View the results in real-time in the summary table and 100 sets of data logs
Application database: pre programmed methods that have been tested and validated can be loaded onto the titrator
The standard kit equipped with 9778BNWP redox electrode is an ideal choice for most standard redox titrations. The electrode has a sturdy and durable glass shell, which is chemically resistant to various samples


Item number START9201 START9200
Accuracy (mV) ±0.2 mV ±0.2 mV
Accuracy (temperature) ±0.2 °C ±0.2 °C
ALARM IN End of titration cycle, large volume of titrant, full data record, calibration due, maintenance reminder End of titration cycle, large volume of titrant, full data record, calibration due, maintenance reminder
Backlight options Yes, adjustable Yes, adjustable
Blank options Using fixed or variable values for titration Using fixed or variable values for titration
Size of burette 10 mL, 20 mL (inclusive), or 50 mL 10 mL, 20 mL (inclusive), or 50 mL
calibration MV and temperature MV and temperature
calibrated point 1-point relative mV (RmV) mode 1-point relative mV (RmV) mode
Certification/Compliance CE, TUV three in one FCC、EN/EIC61326-1、IEC 61010 CE, TUV three in one FCC、EN/EIC61326-1、IEC 61010
thoroughfare 1 1
Number of cycles per titration run 1 to 5 cycles, providing options to exclude cycle results from average and RSD calculations 1 to 5 cycles, providing options to exclude cycle results from average and RSD calculations
Data Management Details Data logs can be exported as CSV or PDF files (short or long format) Data logs can be exported as CSV or PDF files (short or long format)
data point 100 sets of data for each item: sample titration, titrant calibration, calibration, and direct measurement 100 sets of data for each item: sample titration, titrant calibration, calibration, and direct measurement
describe Orion Star T920 Redox Potentiometer Standard Kit Orion Star T920 oxidation-reduction potentiometric titrator (without electrode)
Burette Functions Automatic flushing cycle and discrete separation volume with continuous options; exceed Automatic flushing cycle and discrete separation volume with continuous options; exceed
display type 5.7 "color capacitive touch screen with a resolution of 640 x 480 5.7 "color capacitive touch screen with a resolution of 640 x 480
Functions Available Sample titration, titrant calibration, calibration, and direct measurement Sample titration, titrant calibration, calibration, and direct measurement
type Oxidation-reduction potentiometric titrator Oxidation-reduction potentiometric titrator
Equivalence point 1-2 1-2
Applicable to (application) The determination range of redox titration includes sulfite/SO2 and reducing sugars in fruit juice and wine, ascorbic acid (vitamin C) and peroxide value in food, dissolved oxygen in wastewater (Winkler titration method), and organic matter in soil The determination range of redox titration includes sulfite/SO2 and reducing sugars in fruit juice and wine, ascorbic acid (vitamin C) and peroxide value in food, dissolved oxygen in wastewater (Winkler titration method), and organic matter in soil
include 9778BNWP glass shell redox electrode, 20mL burette, stirrer probe, splitter probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap (with two ports and drying tube), computer cable, USB drive, 110-240 V power supply 20mL burette, mixer probe, splitter probe, standard fitting kit, 1 L plastic bottle, GL38 bottle cap (with two ports and drying tube), computer cable, USB drive, 110-240 V power supply
input BNC (oxidation-reduction/ORP electrode), needle tip (reference electrode), 8-pin MiniDIN (ATC temperature probe), agitator input (agitator probe) BNC (oxidation-reduction/ORP electrode), needle tip (reference electrode), 8-pin MiniDIN (ATC temperature probe), agitator input (agitator probe)
IP protection level IP-51 IP-51
language Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, and Spanish Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, and Spanish
material ABS plastic ABS plastic
storage Non volatile memory can store data records and settings Non volatile memory can store data records and settings
method Up to 10 methods (providing optional password protection); Import/export method through USB flash drive Up to 10 methods (providing optional password protection); Import/export method through USB flash drive
model Orion Star T920 Orion Star T920
output 3 USB ports for printer, USB flash drive, and computer software connections 3 USB ports for printer, USB flash drive, and computer software connections
**Degree 0.5% RSD, Depending on the environment and operating conditions 0.5% RSD, Depending on the environment and operating conditions
Preset endpoints 1-3 1-3
probe Type Redox/ORP electrode, reference half cell electrode, ATC temperature probe, stirrer probe Redox/ORP electrode, reference half cell electrode, ATC temperature probe, stirrer probe
Range (mV) -2000.0-+2000.0 mV -2000.0-+2000.0 mV
Relative humidity range 5 to 85%, non condensing environment 5 to 85%, non condensing environment
resolution The burette driver adopts advanced micro step technology, and the motor can provide 25600 micro steps per revolution to achieve smooth and accurate burette positioning (providing 2 million micro steps throughout the entire burette stroke range) The burette driver adopts advanced micro step technology, and the motor can provide 25600 micro steps per revolution to achieve smooth and accurate burette positioning (providing 2 million micro steps throughout the entire burette stroke range)
Resolution (mV) 0.1 mV 0.1 mV
Resolution (temperature) 0.1 °C 0.1 °C
Sample ID Automatic increment, manual or shutdown Automatic increment, manual or shutdown
Speed of agitator probe 5 user selectable speeds (250 to 3700 RPM) 5 user selectable speeds (250 to 3700 RPM)
Working Temperature (Imperial) 41 ℉ to 104 ℉ 41 ℉ to 104 ℉
Working temperature (metric) 5 ℃ to 40 ℃ 5 ℃ to 40 ℃
Temperature electrode calibration Optional 1-point offset calibration Optional 1-point offset calibration
Temperature range (metric) -5.0 ℃ to+100.0 ℃ -5.0 ℃ to+100.0 ℃
temperature selection Manual or automatic Manual or automatic
Time and date Yes, non-volatile battery backup Yes, non-volatile battery backup
Titration agent determination Calibrate titrant or manually input concentration Calibrate titrant or manually input concentration
Titration process control Conventional, fast, precise, or user-defined Conventional, fast, precise, or user-defined
Titration Setting Wizard Yes, use the 'Start New Titration' workflow Yes, use the 'Start New Titration' workflow
titration technique Equivalent point or preset endpoint Equivalent point or preset endpoint
Titration type Direct titration or back titration Direct titration or back titration
Updating firmware Yes, firmware can be updated using a USB flash drive Yes, firmware can be updated using a USB flash drive
Warranty period 1-year replacement package 1-year replacement package
Dimensions (length x width x height) 10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm 10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm
Electrical requirements 100-240V,50/60 Hz 100-240V,50/60 Hz