**Reproducible results: Through the automatic titration workflow, the same set parameters and calculations can be used each time to perform analysis
• Quick time setting: Use multiple methods to set and save electrode, titrant, and titration parameters only once
• Laboratory throughput has improved: titration has started and instruments are running in unmanned mode
• Reduce costs and downtime: Easy to replace titrator components can minimize maintenance downtime, while durable electrodes can reduce owner costs
• * * Record the test results: View the results in real-time in the summary table and 100 sets of data logs
Application database: pre programmed methods that have been tested and validated can be loaded onto the titrator
The standard kit equipped with 9778BNWP redox electrode is an ideal choice for most standard redox titrations. The electrode has a sturdy and durable glass shell, which is chemically resistant to various samples
| Item number | START9201 | START9200 |
| Accuracy (mV) | ±0.2 mV | ±0.2 mV |
| Accuracy (temperature) | ±0.2 °C | ±0.2 °C |
| ALARM IN | End of titration cycle, large volume of titrant, full data record, calibration due, maintenance reminder | End of titration cycle, large volume of titrant, full data record, calibration due, maintenance reminder |
| Backlight options | Yes, adjustable | Yes, adjustable |
| Blank options | Using fixed or variable values for titration | Using fixed or variable values for titration |
| Size of burette | 10 mL, 20 mL (inclusive), or 50 mL | 10 mL, 20 mL (inclusive), or 50 mL |
| calibration | MV and temperature | MV and temperature |
| calibrated point | 1-point relative mV (RmV) mode | 1-point relative mV (RmV) mode |
| Certification/Compliance | CE, TUV three in one FCC、EN/EIC61326-1、IEC 61010 | CE, TUV three in one FCC、EN/EIC61326-1、IEC 61010 |
| thoroughfare | 1 | 1 |
| Number of cycles per titration run | 1 to 5 cycles, providing options to exclude cycle results from average and RSD calculations | 1 to 5 cycles, providing options to exclude cycle results from average and RSD calculations |
| Data Management Details | Data logs can be exported as CSV or PDF files (short or long format) | Data logs can be exported as CSV or PDF files (short or long format) |
| data point | 100 sets of data for each item: sample titration, titrant calibration, calibration, and direct measurement | 100 sets of data for each item: sample titration, titrant calibration, calibration, and direct measurement |
| describe | Orion Star T920 Redox Potentiometer Standard Kit | Orion Star T920 oxidation-reduction potentiometric titrator (without electrode) |
| Burette Functions | Automatic flushing cycle and discrete separation volume with continuous options; exceed | Automatic flushing cycle and discrete separation volume with continuous options; exceed |
| display type | 5.7 "color capacitive touch screen with a resolution of 640 x 480 | 5.7 "color capacitive touch screen with a resolution of 640 x 480 |
| Functions Available | Sample titration, titrant calibration, calibration, and direct measurement | Sample titration, titrant calibration, calibration, and direct measurement |
| type | Oxidation-reduction potentiometric titrator | Oxidation-reduction potentiometric titrator |
| Equivalence point | 1-2 | 1-2 |
| Applicable to (application) | The determination range of redox titration includes sulfite/SO2 and reducing sugars in fruit juice and wine, ascorbic acid (vitamin C) and peroxide value in food, dissolved oxygen in wastewater (Winkler titration method), and organic matter in soil | The determination range of redox titration includes sulfite/SO2 and reducing sugars in fruit juice and wine, ascorbic acid (vitamin C) and peroxide value in food, dissolved oxygen in wastewater (Winkler titration method), and organic matter in soil |
| include | 9778BNWP glass shell redox electrode, 20mL burette, stirrer probe, splitter probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap (with two ports and drying tube), computer cable, USB drive, 110-240 V power supply | 20mL burette, mixer probe, splitter probe, standard fitting kit, 1 L plastic bottle, GL38 bottle cap (with two ports and drying tube), computer cable, USB drive, 110-240 V power supply |
| input | BNC (oxidation-reduction/ORP electrode), needle tip (reference electrode), 8-pin MiniDIN (ATC temperature probe), agitator input (agitator probe) | BNC (oxidation-reduction/ORP electrode), needle tip (reference electrode), 8-pin MiniDIN (ATC temperature probe), agitator input (agitator probe) |
| IP protection level | IP-51 | IP-51 |
| language | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, and Spanish | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, and Spanish |
| material | ABS plastic | ABS plastic |
| storage | Non volatile memory can store data records and settings | Non volatile memory can store data records and settings |
| method | Up to 10 methods (providing optional password protection); Import/export method through USB flash drive | Up to 10 methods (providing optional password protection); Import/export method through USB flash drive |
| model | Orion Star T920 | Orion Star T920 |
| output | 3 USB ports for printer, USB flash drive, and computer software connections | 3 USB ports for printer, USB flash drive, and computer software connections |
| **Degree | 0.5% RSD, Depending on the environment and operating conditions | 0.5% RSD, Depending on the environment and operating conditions |
| Preset endpoints | 1-3 | 1-3 |
| probe Type | Redox/ORP electrode, reference half cell electrode, ATC temperature probe, stirrer probe | Redox/ORP electrode, reference half cell electrode, ATC temperature probe, stirrer probe |
| Range (mV) | -2000.0-+2000.0 mV | -2000.0-+2000.0 mV |
| Relative humidity range | 5 to 85%, non condensing environment | 5 to 85%, non condensing environment |
| resolution | The burette driver adopts advanced micro step technology, and the motor can provide 25600 micro steps per revolution to achieve smooth and accurate burette positioning (providing 2 million micro steps throughout the entire burette stroke range) | The burette driver adopts advanced micro step technology, and the motor can provide 25600 micro steps per revolution to achieve smooth and accurate burette positioning (providing 2 million micro steps throughout the entire burette stroke range) |
| Resolution (mV) | 0.1 mV | 0.1 mV |
| Resolution (temperature) | 0.1 °C | 0.1 °C |
| Sample ID | Automatic increment, manual or shutdown | Automatic increment, manual or shutdown |
| Speed of agitator probe | 5 user selectable speeds (250 to 3700 RPM) | 5 user selectable speeds (250 to 3700 RPM) |
| Working Temperature (Imperial) | 41 ℉ to 104 ℉ | 41 ℉ to 104 ℉ |
| Working temperature (metric) | 5 ℃ to 40 ℃ | 5 ℃ to 40 ℃ |
| Temperature electrode calibration | Optional 1-point offset calibration | Optional 1-point offset calibration |
| Temperature range (metric) | -5.0 ℃ to+100.0 ℃ | -5.0 ℃ to+100.0 ℃ |
| temperature selection | Manual or automatic | Manual or automatic |
| Time and date | Yes, non-volatile battery backup | Yes, non-volatile battery backup |
| Titration agent determination | Calibrate titrant or manually input concentration | Calibrate titrant or manually input concentration |
| Titration process control | Conventional, fast, precise, or user-defined | Conventional, fast, precise, or user-defined |
| Titration Setting Wizard | Yes, use the 'Start New Titration' workflow | Yes, use the 'Start New Titration' workflow |
| titration technique | Equivalent point or preset endpoint | Equivalent point or preset endpoint |
| Titration type | Direct titration or back titration | Direct titration or back titration |
| Updating firmware | Yes, firmware can be updated using a USB flash drive | Yes, firmware can be updated using a USB flash drive |
| Warranty period | 1-year replacement package | 1-year replacement package |
| Dimensions (length x width x height) | 10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm | 10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm |
| Electrical requirements | 100-240V,50/60 Hz | 100-240V,50/60 Hz |
| Unit Size | Each | Each |