-
Phone
13910499766
-
Address
Building 5, Guanghua Entrepreneurship Park, No. 18 Anningzhuang East Road, Haidian District, Beijing
Beijing Lijia United Technology Co., Ltd
13910499766
Building 5, Guanghua Entrepreneurship Park, No. 18 Anningzhuang East Road, Haidian District, Beijing
The Picarro PI5310 gas concentration analyzer is specifically designed for high-precision measurement of nitrous oxide in the atmosphere(N2O)And carbon monoxide (CO). Mid infrared (IR) cavity ring down spectroscopy (CRDS) technology achieves an accuracy of one trillionth of a ppt in the measurement range of 1 to 1500 ppb at intervals of less than 5 seconds. Because the drift is less than 0.1 ppb, the analyzer does not require frequent calibration and maintenance. Water vapor(H2O)Measurement accuracy of one millionth (ppm), used for calibration and reporting in dry mole fractionN2OAnd CO concentration. This analyzer has a Linux operating system and can be configured to automatically export measurement data through Ethernet, RS-232 interface, analog 4-20mA or Modbus output.
Nitrous oxide is a naturally occurring greenhouse gas that plays a crucial role in the nitrogen cycle. Although it remained stable before the Industrial Revolution, its concentration in the atmosphere sharply increased due to agricultural practices and fossil fuel combustion. Accurately measuring in the atmosphereN2OIt is very important to understand the human impact on the Earth's climate.
Carbon monoxide is also a natural compound formed by incomplete combustion. Like greenhouse gases, atmospheric concentrations increase with industrialization, mainly due to the use of fossil fuels. Accurate measurement of carbon monoxide is crucial for atmospheric monitoring due to its role in radiative forcing. Like other Picarro greenhouse gas (GHG) analyzers, the PI5310 is an ideal instrument for long-term atmospheric monitoring, highly suitable for demanding greenhouse gas monitoring networks such as the World Meteorological Organization (WMO) and the Integrated Carbon Observing System (ICOS).
Simultaneously measuring N2O and CO gas concentrations with an accuracy of up to 20 ppt
Excellent long-term stability and low drift
Measure water vapor and report dry mole fraction
Excellent pressure and temperature stability
Meet the requirements of the World Meteorological Organization (WMO) greenhouse gas compatibility targets and the Integrated Carbon Observing System (ICOS) atmospheric monitoring station specifications

| Picarro PI5310 Performance Specifications | N2O | CO | H2O |
| Accuracy (1 σ, 5 seconds) | < 0.2='' (='' n2o=''>< 500='' ppb=''> Typical value=0.10 ppb* |
< 0.2='' (='' co=''>< 400='' ppb=''> Typical value=0.13 ppb* |
< 40=''> |
| Accuracy (1 σ, 5 minutes) | < 0.04='' ppb='' (='' n2o=''>< 500='' ppb=''> | < 0.04='' ppb='' (='' co=''>< 400='' ppb=''> | < 6=''> |
| Typical value=0.015 ppb* | Typical value=0.019 ppb* | ||
| Accuracy (1 σ, 1 hour) | < 0.02='' ppb='' (='' n2o=''>< 500='' ppb=''> | < 0.02='' ppb='' (='' co=''>< 400='' ppb=''> | - |
| Accuracy (1 σ, 5 minutes) | 0.03% N2O reading (N2O>500 ppb) | 0.02% CO reading (CO>400 ppb) | < 6=''> |
| Drift (24 hours) | < 0.1=''> Typical value=0.036 ppb* |
< 0.1=''> Typical value=0.046 ppb* |
- |
| measuring range | 1–1500 ppb | 1–1500 ppb | 0–3% |
| Measurement Interval | < 5=''> | ||
| Typical value=2.7 seconds* | |||
*Typical performance is defined as the median of test results from more than 10 consecutive Pl5310 equivalent analyzers. Results can be requested.
| Picarro PI5310 System Specifications | |||
| measurement | Cavity ring down spectroscopy (CRDS) technology | ||
| Measurement pool temperature control | ±0.005 ℃ | ||
| Measurement pool pressure control | ± 0.0002 atmospheric pressure | ||
| sample temperature | -10 to 45 ℃ | ||
| Sample pressure | 300 to 1000 Torr (40 to 133 kPa) | ||
| Sample flow rate | 200 standard cubic centimeters | ||
| Sample humidity | <99% relative humidity (at='' 40='' ℃=''>99%) | ||
| ambient temperature | 15 to 35 ℃ (working conditions) | ||
| -10 to 50 ℃ (storage conditions) | |||
| ambient humidity | < 85%=''> | ||
| accessory | Including: pump (external), keyboard, mouse Optional: LCD display, maintenance kit |
||
| data output | RS-232 interface, network interface, USB interface, Modbus, 4-20mA (optional) | ||
| Air inlet connector | ¼ inch stainless steel Swagelok ® Pipe joint | ||
| size | Analyzer: 16.65 inches wide x 9.25 inches high x 30.25 inches long (42.3 x 23.5 x 76.8 centimeters), including footrests External pump: 7.5 inches wide x 4 inches high x 11 inches long (19.1 x 10.2 x 27.9 centimeters) |
||
| Installation form | Desktop or 19 inch rack installation | ||
| weight | Analyzer 71 pounds (32.2 kilograms) External pump 14.3 pounds (6.5 kilograms) |
||
| Power requirements | 100-240 volts AC, 50/60 hertz,<> Steady state operation: 250 W (analyzer) and 150 W (pump) |
||
| authentication certificate | CE certificate of conformity | ||