| Technical specifications of PTV1000 online turbidity tester | |
| Measurement parameters | measuring range |
| Turbidity | 0.0001 - 100 NTU |
| technical specifications | |
| optical properties | Infrared light & White LED |
| Power supply requirements | 90-264 V, AC, 50-60 Hz, automatic selection |
| accuracy | Range value fluctuates by ± 2% between 0 and 10 NTU Between 10 and 100 NTU, the range value fluctuates by ± 4% |
| stray | Less than 0.005/5 mNTU |
| display resolution | Up to 0.0001 NTU (depending on range) or 5 display bits |
| Repeatability/Accuracy | At 1 NTU, it is better than 1% |
| initial response | 10% change: 15 seconds at maximum traffic |
| Step response | T-90), 200 milliliters per minute in less than 240 seconds. At 1NTU |
| signal averaging | Optional: 1, 3, 6, 10, 30, 60, and 90 seconds, with a standard setting of 30 seconds |
| sample temperature | 0-50 ° C, the highest sample temperature is 70 ° C |
| calibration | Single point calibration using licensed formalin solution for 5.0 or 20NTU |
| sample flow | 30 to 500 ml/min, optimal condition 50 to 80 ml/min |
| injection port | 1/4 inch NPT female head, 1/4 inch compression hose (included) |
| Sample outlet | (Drainage) 3/8-inch NPT female head, 3/8-inch hose connector (included) |
| Injection tube | 1/4 inch OD or 6 mm OD |
| Sample tube | 3/8 inch OD or 9 mm OD |
| Turbidity meter emptying | Quick connector for integrated globe valve |
| Analog output: Measurement module | You can choose between 0-20mA or 4-20mA; The output range can be programmed through each segment of the measuring range |
| Analog output: power box connection | You can choose between 0-20mA or 4-20mA; The output range can be programmed through each segment of the measuring range |
| call the police | Three set-point alarms, each equipped with an SPDT relay with unpowered contacts rated 5 A resistive load at 230 V, AC |
| Digital protocol | 4-20 mA |
| Type of junction box casing | Polyester fiber reinforcement |
| Protection level of junction box shell | IP 66 |
| safety | Registered by T Ü V Rheinland, compliant with UL 61010A-1: certified by T Ü V Rheinland, compliant with CSAC22.2 No.1010.1: CE certified by T Ü V Rheinland, compliant with 61010-1 |
| immunity | CE certification by T Ü V Rheinland, compliant with 61326 (industrial standard) |
| Emissions | Grade A: EN 61326, CISPR 11, FCC Part 15, Canadian standard for interference causing digital devices ICES-003 |
| install hardware | Turbidity meter sensor - slotted mounting bracket, can be fixed on any vertical plane or panel (optional). Junction box - directly installed on any vertical plane or panel (optional) |
| authentication method | Wet standard (stable formalin solution) or dry detection device |
| Limit of Determination | 0.0005 NTU |
| detection limit | 0.005 NTU |
| environmental condition | 5-50 ° C, relative humidity 5-95% (non condensing) |
| consistency | ISO 7027 |
| protection grade | IP 65 |
| size | 158.4 x 340.4 x 334.5 mm |
| weight | 5 kg |