- Phone
-
Address
Room 1705, Tianhe Commercial Building, No. 8 Zhongshan Avenue, Guangzhou
Guangzhou Yitong Instrument Equipment Co., Ltd
Room 1705, Tianhe Commercial Building, No. 8 Zhongshan Avenue, Guangzhou
In order to meet the increasing demand for portable toxicity testers in the environmental protection, health and disease control, and water supply industries in recent years, especially since the 5.12 earthquake, Hash Corporation in the United States has launched a luminescent bacteria detection method based on the Eclox chemiluminescence portable water toxicity analyzer. Enable the instrument to support both luminescent bacteria and chemiluminescence toxicity detection methods simultaneously. The luminescent bacteria method biological toxicity analysis reagent complies with the international standard ISO11348, and the test results are accurate and reliable. The chemiluminescence method for toxicity analysis can be used for toxicity detection in harsh testing environments, and this method has significantly better toxicity reactions to trace organic matter pollution than the luminescent bacteria method.
Hash's EcloxTM can be widely used for toxicity analysis purposes such as environmental pollution, emergency accidents, security checks, routine testing, and analytical research. The convenient measurement mode, unique hash data analysis table, and the ability to detect six important water quality testing parameters fully ensure the accuracy of water toxicity assessment. The sturdy casing, waterproof and dustproof, and portable instrument design meet the needs of on-site measurements.
EcloxTM has the following characteristics:
One instrument can support two toxicity analysis methods: luminescent bacteria method and chemiluminescence method
The pre made reagent for luminescent bacteria method is freeze-dried powder that complies with ISO11348
Pre made reagents using chemiluminescence method can be stored at room temperature. Low environmental requirements. And it is more sensitive to the toxicity of organic compounds.
• Reagent preparation and instrument testing operations are simple and fast
• Sensitive to various heavy metals, toxins, and chemical warfare agents
Add 6 important water quality parameter detection capabilities to provide a comprehensive solution for toxicity testing
The toxicity analysis results are reliable
The instrument is sturdy and durable, waterproof and dustproof. Lightweight and easy to carry
• Having data download software for further data processing
Instrument technical specifications:
module |
Chemiluminescence Toxicity Test (CT) |
Luminescent Bacterial Toxicity Test (LBT) | |
Luminescent bacterial method module |
Luminous intensity testing mode |
Toxicity screening mode | |
certification |
EU CE certification |
Instrument operating temperature |
-20 to 55℃ |
environment |
IP67。 Waterproof and dustproof |
weight |
1.4kg (instrument, including battery) |
size |
Instrument: 230 × 77 × 125mm |
Power type |
4 AA; each group of batteries can undergo at least 250 tests |
screen display |
Graphic LCD display screen with backlight function |
data storage |
32K bytes of result storage space |
data output |
RS232 |
measure time |
Default 15 seconds (6 to 20 seconds optional) |
Scope of screening |
0-100% inhibition rate (10-90% linear inhibition) |
Screening test time |
5, 15, or 30 minutes |
Instrument warranty period |
1 year |
Luminescent bacteria |
Freeze dried Vibrio fischeri (NRRL B-11777) compliant with ISO11348 |
Bacterial storage temperature |
-At 18 ℃, it can be stored for one year, and at a maximum temperature of 25 ℃, it can be stored for up to one week |
Additional parameter testing |
Arsenic, luminescent toxicity, residual chlorine, total chlorine, platinum cobalt color, nerve agents, insecticides pH、 Total dissolved solids (conductivity) |
Shelf life of reagents |
Luminescence method: can be stored for 1 year at -18 ℃ |