Welcome Customer !

Membership

Help

Jinan Zhongce Electromechanical Equipment Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Jinan Zhongce Electromechanical Equipment Co., Ltd

  • E-mail

    sales01@pubtester.com

  • Phone

    18660817670

  • Address

    A3-02 Yinfeng International Biotech City Park, Gaoxin East District, Jinan City, Shandong Province

Contact Now

Pre filled syringe collar pull-out force tester complies with Pharmacopoeia 4043

NegotiableUpdate on 01/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The pre filled syringe collar pull-out force tester meets the requirements of Pharmacopoeia 4043. It mainly verifies the connection strength between the collar and the syringe cone head through axial tension testing to evaluate the firmness of the adapter collar under axial force and prevent detachment during assembly or injection .....

Product Details


Pre filled syringe collar pull-out force tester complies with Pharmacopoeia 4043termsRequirement: The main purpose is to verify the connection strength between the collar and the syringe cone through axial tensile testing, in order to evaluate the firmness of the adapter collar under axial force and prevent detachment during assembly or injection process .....


预灌封注射器卡圈拔出力测试仪 符合药典4043

Pre filled syringe collar pull-out force tester complies with Pharmacopoeia 4043terms


Instrument requirements

    • Measurement range: 1N-200N, indication error ≤ ± 1%.

    • Function: Supports pulling, peeling and other tests, in compliance with Pharmacopoeia 4043 standard. ‌

  • TST-01b medical device pull-out force tester
    • Measurement accuracy: ± 0.5%, supporting a standard speed of 20mm/min. ‌

test method

  1. Sample preparation: Remove the conical cap and fix the syringe vertically.

  2. Equipment calibration: Zero force sensor, set testing rate (usually 20mm/min).

  3. Perform test: Apply axial tension and record the peak force of the force displacement curve. ‌

The results indicate

The pull-out force is expressed as peak force (unit: Newton) and must meet the requirements of Pharmacopoeia 4043.



TST-01B adapter card ring pull-out force testerProduct Features

·The transmission structure of high-precision ball nut screw combined with a new three column guide sleeve makes the system run more smoothly

·0.5 level high-precision force sensor, effectively ensuring the accuracy and repeatability of test results

·Equipped with advanced displacement control system, the displacement accuracy can reach 0.1mm

·Paired with advanced servo drive system, it can achieve infinite variable speed and meet the testing needs of users under different testing conditions

·Multiple specifications of force sensors to meet various force testing requirements

·7-inch color touch screen with intelligent data processing function, providing users with a comfortable and smooth operating experience

·Concise and intuitive user interface, convenient user-defined testing functions, and comprehensive data analysis and reporting capabilities

·Built in test file standard library, compliant with various international testing methods

·Intelligent configurations such as limit protection, overload protection, automatic return, and power-off memory effectively ensure the safety of user operations

·Configure a standard serial communication port that can connect to computer software for convenient data processing and transmission

·Featuring a wide range of applications and equipped with multiple sample fixtures for users to choose from, it can meet the testing requirements of over 10000 materials

·Pubtester also provides professional customization services to meet the personalized needs of users in terms of fixtures, software, and other aspects