Specification 8048 PortaCount respirator suitability tester | ||
Suitable factor range |
Above 1-10000, N95 face mask ranges from 1-200 |
|
Typical suitability factor accuracy |
± 10% of the count |
|
Respiratory mask for suitability testing |
Elastic full face cover Elastic half face mask NIOSH100 series filter face mask NIOSH 99 series filter face mask NIOSH 95 series filter face mask FFP1, FFP2, FFP3 series respirators |
|
Suitable for factor measurement |
Direct measurement of suitability factors (Cout and Cin)* |
|
size |
12cm x 27cm x 24cm(4.83in.x10.5in.x9.46in.) |
|
weight |
Single device |
32KG(7.01lb) |
Including standard accessories and instrument boxes |
6.9kg(15.35lb) |
|
power supply |
100~250VAC,50~60Hz) |
|
traffic |
sampling flow |
350cm3/min |
Total traffic |
1000cm3/min (nominal value) |
|
temperature range |
Operating temperature |
0~38℃(32~100℉) |
Storage temperature |
-40~50℃(-40~122℉) |
|
working fluid |
99.5% reagent grade isopropanol |
|
Running time after fully charged |
6 hours at a temperature of 21 ℃ (70 ℉) |
|
Instrument box |
Size (HWD) |
25.4cm x 52.1cm x 39.4cm (10.0in x 20.5in. x 15.5in.) |
Pass/fail setting |
user-defined |
0~10000 |
Factory calibration interval |
a year |
|
communication |
WiFi,USB-C,USB-A |
|
Minimum PC hardware requirements for FitPro Ultra suitability testing software |
Windows 7 (32 and 64 bit), Windows 8 (32 and 64 bit), or Windows 10 (32 and 64 bit) operating systems Microsoft. net version 4 (if software installation is required, Microsoft. net will be installed) Note - Installing Microsoft. net requires an internet connection ≥1GHz Display screen resolution ≥ 1280 x 800 500MB of free space on the hard drive 1 USB interface |
|
Minimum requirements for tablet computers |
Windows 10 operating system USB port (for initial setup) |
|
software |
FitPro Ultra software features an advanced user interface, animated tutorials, and interactive troubleshooting guide |
|
Optional Accessories |
Sampling adapter corresponding to the selected respirator model Microsoft Surface Pro tablet (4GB RAM, 128GB storage) Wireless USB encryption dongle |
|
Suction suitability tester
Model: 8048
TSI8048 Protective Face Mask Suitability Tester (Respirator Suitability Tester),8048 Protective Mask Suitability TesterEquipped with intelligent touchscreen solutions, it supports respiratory protection plans throughout the entire process from personnel training to compliance testing.
The TSI PortaCount Respirator Suitability Tester 8048 is the only testing instrument in the United States that provides a consistent and objective testing experience. It is suitable for various types of respirators, including N95 filter masks, and the instrument also has FitCheck ™ New features such as mode and suitability testing animation tutorials help users better and faster verify the suitability of respirators.
The FitCheck mode displays real-time changes in the suitability of the respirator throughout the entire wearing and adjustment process, helping users select the appropriate respirator and achieve optimal suitability faster.
Animated tutorial videos can guide employees to correctly perform each inspection training, provide a consistent inspection experience, and reduce personnel costs.
PortaCount 8048 is the most reliable suitability testing instrument, providing you with improved employee safety and productivity.
Application instruments for quantitative suitability testing of all tight fitting respirators, including N95, P1, and P2 filter masks.
No need to generate aerosols of specific concentrations... You only need to choose the Environmental Aerosol Condensed Core Particle Counter (CNC) quantitative suitability testing instrument. The PortaCount8048 respirator suitability testing instrument also uses N95 Compassion particle size screening technology.
The 8048 PortaCount instrument components include:
·Built in N95 Compassion technology
·Carrying case
·AC adapter
·FitPro UItra software
·Particle Generator
·Standard accessory package (dual air tube, zero adjustment filter, spare liquid suction core, alcohol filling bottle, USB data cable)
·Filter mask suitability testing kit (sampling probe installation tool, sampling probe, probe locking nut, hanging rope)
FitPro Ultra software
·The new version of FirPro Ultra suitability testing software has improved efficiency and simplified the testing steps
·The new advanced user interface features an intuitive design that allows for quick access to suitability testing
·Equipped with wireless WiFi communication function operated through laptops or tablets
·The industry's first animation tutorial guides employees to complete suitability testing training faster, ensuring higher compliance
·Interactive Troubleshooting Guide
Features and advantages
·Compliant with OSHA, CSA, HSE, and ANSI standards, suitable for all close fitting respirators, including: 95, 99, 100, FFP1, FFP2, and FFP3 filter respirators
·The suitability factor for measurement can be greater than 10000
·Using tiny particles in ambient air to calculate the suitability factor of respirators
·Automatically perform suitability testing using FitPro Uitra software
·Real time FitCheck mode can train new users and eliminate failed suitability checks
·The mask sampling adapter kit can be used for suitability testing on employees' personal respirators
·The suitability inspection card can be printed on the suitability inspection report or ID card through software
tsi8048 Protective Mask Suitability Tester, TSI8048, TSI8048, USA
Tags: tsi, tsi8048, tsi8038, tsi8048 Respiratory Tester, tsi Protective Mask Suitability Tester 8048, TSI, USAProtective mask suitability tester8048, TSI8048, TSI8048, TSI Protective Mask Suitability Tester 8048, N95 Mask Tester, Mask Tester, TSI Protective Mask Suitability Tester, TSI8048 Protective Mask Suitability Tester, TSI Agent, Quest Instrument