Overview
The new PortaCount 8048 respirator suitability tester from TSI in the United States features an intelligent touchscreen solution that supports respiratory protection plans throughout personnel training and compliance testing. The TSI PortaCount Respirator Suitability Tester 8048 is the only testing instrument in the United States that provides a consistent and objective testing experience. It is suitable for various types of respirators, including N95 filter masks, and the instrument also has FitCheck ? New features such as mode and suitability testing animation tutorials help users better and faster verify the suitability of respirators.
Product Details


Specification 8048 PortaCount respirator suitability tester

Suitable factor range

Above 1-10000, N95 face mask ranges from 1-200

Typical suitability factor accuracy

± 10% of the count

Respiratory mask for suitability testing

Elastic full face cover

Elastic half face mask

NIOSH100 series filter face mask

NIOSH 99 series filter face mask

NIOSH 95 series filter face mask

FFP1, FFP2, FFP3 series respirators

Suitable for factor measurement

Direct measurement of suitability factors (Cout and Cin)*

size

12cm x 27cm x 24cm(4.83in.x10.5in.x9.46in.)

weight

Single device

32KG(7.01lb)

Including standard accessories and instrument boxes

6.9kg(15.35lb)

power supply

100~250VAC,50~60Hz)

traffic

sampling flow

350cm3/min

Total traffic

1000cm3/min (nominal value)

temperature range

Operating temperature

0~38℃(32~100℉)

Storage temperature

-40~50℃(-40~122℉)

working fluid

99.5% reagent grade isopropanol

Running time after fully charged

6 hours at a temperature of 21 ℃ (70 ℉)

Instrument box

Size (HWD)

25.4cm x 52.1cm x 39.4cm

(10.0in x 20.5in. x 15.5in.)

Pass/fail setting

user-defined

0~10000

Factory calibration interval

a year

communication

WiFi,USB-C,USB-A

Minimum PC hardware requirements for FitPro Ultra suitability testing software

Windows 7 (32 and 64 bit), Windows 8 (32 and 64 bit), or Windows 10 (32 and 64 bit) operating systems

Microsoft. net version 4 (if software installation is required, Microsoft. net will be installed) Note - Installing Microsoft. net requires an internet connection

≥1GHz

Display screen resolution ≥ 1280 x 800

500MB of free space on the hard drive

1 USB interface

Minimum requirements for tablet computers

Windows 10 operating system

USB port (for initial setup)

software

FitPro Ultra software features an advanced user interface, animated tutorials, and interactive troubleshooting guide

Optional Accessories

Sampling adapter corresponding to the selected respirator model

Microsoft Surface Pro tablet (4GB RAM, 128GB storage)

Wireless USB encryption dongle


Suction suitability tester

Model: 8048


TSI8048 Protective Face Mask Suitability Tester (Respirator Suitability Tester),8048 Protective Mask Suitability TesterEquipped with intelligent touchscreen solutions, it supports respiratory protection plans throughout the entire process from personnel training to compliance testing.

The TSI PortaCount Respirator Suitability Tester 8048 is the only testing instrument in the United States that provides a consistent and objective testing experience. It is suitable for various types of respirators, including N95 filter masks, and the instrument also has FitCheck ™ New features such as mode and suitability testing animation tutorials help users better and faster verify the suitability of respirators.

The FitCheck mode displays real-time changes in the suitability of the respirator throughout the entire wearing and adjustment process, helping users select the appropriate respirator and achieve optimal suitability faster.

Animated tutorial videos can guide employees to correctly perform each inspection training, provide a consistent inspection experience, and reduce personnel costs.

PortaCount 8048 is the most reliable suitability testing instrument, providing you with improved employee safety and productivity.

Application instruments for quantitative suitability testing of all tight fitting respirators, including N95, P1, and P2 filter masks.

No need to generate aerosols of specific concentrations... You only need to choose the Environmental Aerosol Condensed Core Particle Counter (CNC) quantitative suitability testing instrument. The PortaCount8048 respirator suitability testing instrument also uses N95 Compassion particle size screening technology.

The 8048 PortaCount instrument components include:

·Built in N95 Compassion technology

·Carrying case

·AC adapter

·FitPro UItra software

·Particle Generator

·Standard accessory package (dual air tube, zero adjustment filter, spare liquid suction core, alcohol filling bottle, USB data cable)

·Filter mask suitability testing kit (sampling probe installation tool, sampling probe, probe locking nut, hanging rope)

FitPro Ultra software

·The new version of FirPro Ultra suitability testing software has improved efficiency and simplified the testing steps

·The new advanced user interface features an intuitive design that allows for quick access to suitability testing

·Equipped with wireless WiFi communication function operated through laptops or tablets

·The industry's first animation tutorial guides employees to complete suitability testing training faster, ensuring higher compliance

·Interactive Troubleshooting Guide

Features and advantages

·Compliant with OSHA, CSA, HSE, and ANSI standards, suitable for all close fitting respirators, including: 95, 99, 100, FFP1, FFP2, and FFP3 filter respirators

·The suitability factor for measurement can be greater than 10000

·Using tiny particles in ambient air to calculate the suitability factor of respirators

·Automatically perform suitability testing using FitPro Uitra software

·Real time FitCheck mode can train new users and eliminate failed suitability checks

·The mask sampling adapter kit can be used for suitability testing on employees' personal respirators

·The suitability inspection card can be printed on the suitability inspection report or ID card through software

tsi8048 Protective Mask Suitability Tester, TSI8048, TSI8048, USA

Tags: tsi, tsi8048, tsi8038, tsi8048 Respiratory Tester, tsi Protective Mask Suitability Tester 8048, TSI, USAProtective mask suitability tester8048, TSI8048, TSI8048, TSI Protective Mask Suitability Tester 8048, N95 Mask Tester, Mask Tester, TSI Protective Mask Suitability Tester, TSI8048 Protective Mask Suitability Tester, TSI Agent, Quest Instrument