LGR (currently under ABB Canada)The Rapid Methane Analyzer(FMA)Easy to operate, low power consumption, sturdy and durable, it is an ideal tool for field monitoring of methane. Quick measurement(20 Hz)Its characteristics make it a better choice for vortex related covariance flux measurement and soil flux research.
FMADesigned for various purposes, including vortex related flux measurement using micro meteorological technology, chamber method flux measurement, and natural gas pipeline leakage inspection, it has the characteristics of high accuracy and fast response. The analyzer is not affected by interference from other gases in the atmosphere (no cross interference), nor is it affected by changes in atmospheric pressure (no pressure broadening effect).LGRThe uniquely designed "dynamic dilution system" option canCH4Range extension100Multiple times or more, and ensure that the accuracy and sensitivity are consistent with measurements taken at typical environmental levels.
FMAuseLGROutput spectrum of off-axis integrating cavity with patented design(OA-ICOS)Technology (patent number: 6795190), which eliminatesCRDSDuring the measurement process, technology requires continuous matching of the optical cavity and laser wavelength to improve the weak signal intensity, eliminating the need for complex laser alignment adjustment, temperature control, and wavelength monitoring in the analyzer. Real time display of high-resolution laser absorption spectra. Using a built-in computer(Linux OS)To provide continuous storage and measurement of data. With remote control function, users can operate the analyzer from any location through the network, and can also share real-time data and perform instrument diagnosis through remote login.
characteristic:
1. 20 HzIdeal tool for high-frequency measurement and eddy related flux measurement
2. Operation range0~45 ℃Compact, durable, low-power, a better choice for field monitoring
3. Performance exceeds expectationsWMOTechnical specifications for greenhouse gas monitoring
4. Real time visible high-resolution absorption spectra for easy diagnosis
5.moreWide measurement range (achievable)1000 ppm), and the full range is linear
6. Nature、ScienceWaiting for a large number of articles to be published in journals, more authoritative methane analyzers
Performance indicators:
repeatability/accuracy(1σ,1 second/ 100Seconds)
CH4:3 ppb / 0.3 ppb
H2O:150 ppm / 50 ppm
Drift(EPType,15Minute average, standard temperature and pressure,24Hour)
CH4:0.8 ppb
H2O:100 ppmOr reading1%The larger one shall prevail
Measurement speed:
0.01~20 Hz
Accuracy (under all operating temperature conditions):
Uncertainty<1%Under uncalibrated conditions (standard type)
Uncertainty<0.03%Without calibration conditions(EPType)
Measurement range (100 seconds):
CH4:0.01~100 ppm
H2O:1000~70000 ppm
Optional range:
CH4:0~1000 ppm
CH4:0~10%(Need to increase)Extended Range Options)
H2O:0~70000 ppm(0~100% RH)
Environmental conditions:
Sample temperature:0~50℃
Operating temperature:5~45℃(Standard type)/ 0~45℃(EPType)
ambient humidity:0~100% RH, without condensation
Output:
Number(RS 232)Simulation, EthernetUSB
Electricity demand:
115/230 VAC,50/60 Hz,80 W(Standard type)/ 150 W(EPType)
Size and weight:
EPtype,Rack:40 cm(H)x 48.3 cm(W)x 61 cm(D),40 kg
Ordering information:
Model number(Model):
GLA331-CH4(EPtype, rack mounted)
Optional items:
1. 908-0003-9001perhapsMIU-377-16:16Road multiplexer
2. 908-0003-9002perhapsMIU-374-8:8Road multiplexer
3. 908-0008-9009:N920Vacuum pump (gas update time)1.2Seconds)
4. 908-0001-9011:N940Vacuum pump (gas update time)0.7Seconds)
5. 908-0001-9001:Dry ScrollVacuum pump (gas update time<0.1Seconds)
6. 907-0005-9002Dynamic dilution system, range expansion100times
7. 904-0002Data collection software (includingUSB/RS 232Cable), capable of recording and synchronizing multiple devicesLGRAnalyzer or other equipment (such asGPSData output from anemometers, etc
manufacturer:
ABB Canada