E-mail
940009794@qq.com
-
Phone
1395802750715968172475
-
Address
No. 159, Nanshan North Road, Renhe Street, Yuhang District, Hangzhou City
Hangzhou Weige Electronic Technology Co., Ltd
940009794@qq.com
1395802750715968172475
No. 159, Nanshan North Road, Renhe Street, Yuhang District, Hangzhou City
|
Serial Number
|
Name of goods
|
Main specifications
|
quantity
|
notes
|
|
1
|
Industrial Control Computer
|
Advantech Industrial Control Computer
|
1 set
|
Rotating Transformer
Stator safety comprehensive testing system
(Workstation 1)
|
|
2
|
High speed acquisition module
|
XMP240
|
1 piece
|
|
|
3
|
Electrical control module
|
XRE1936
|
1 piece
|
|
|
4
|
High voltage relay board
|
DY-10KV
|
1 piece
|
|
|
5
|
Voltage withstand insulation testing module
|
XNJ271
|
1 piece
|
|
|
6
|
DC resistance testing module
|
XDZ250
|
1 piece
|
|
|
7
|
Interturn insulation withstand voltage module
|
XDZ260
|
1 piece
|
|
|
8
|
Cabinet and wiring
|
VG-2X-ATE
|
1 set
|
|
|
1
|
Rotary amplitude and impedance tester
|
PA333
|
1 piece
|
Rotating Transformer
Performance parameter testing
(Workstation 2)
|
|
2
|
Excitation power supply
|
10KHZ/30V
|
1 unit
|
|
|
3
|
Rotary angle meter
|
FB99
|
1 unit
|
|
|
4
|
Rotary servo table
|
Non standard
|
1 unit
|
|
|
5
|
Industrial Control Computer
|
Advantech Industrial Control Computer
|
1 set
|
|
|
6
|
Cabinet and wiring
|
VG-2X-ATE
|
1 set
|
|
DC Resistance
|
Test conditions: Automatic measurement and display of ambient temperature using DC constant current source
Measurement range: 1-10-100m Ω (converted from computer resistance value to 20 ℃ resistance value)
Measurement accuracy: ± 1% (accurate to 2 decimal places)
|
|
electric strength
|
Test voltage: AC 500-3000V (voltage programmable) 50HZ
Measurement accuracy: ± 5%
Leakage current: 0.1-20mA (automatic range switching) Measurement accuracy: ± 5%
Test time: 1-100 seconds adjustable
|
|
impedance
|
Test frequency: 0-10KHZ Level voltage: 30V/5mA
Impedance: 0.00001-99.9999M Ω Measurement accuracy: ± 0.5%
|
|
insulation resistance
|
Test voltage: DC500V, DC1000V,
Measurement range: 1.0-500M Ω (automatic range switching) Measurement accuracy: ± 5%
Test time: 1-100 seconds adjustable
|
|
Interturn insulation withstand voltage test
|
Test voltage: AC 500-3000V (voltage programmable) Measurement accuracy: ± 5%
Waveform comparison method: area difference, area difference
|
|
Rotary zero position test
|
Excitation voltage test 10KHZ/30V, rotation angle test, zero position voltage, test accuracy ± 0.5%
|
|
Peak voltage test of rotary converter
|
Excitation voltage test 10KHZ/30V, test the peak values of the sine and cosine voltages of the rotary transformer (24 points in total every 180 degrees)
Test accuracy ± 0.5%
|
|
Rotating electrical angle test
|
Excitation voltage test 10KHZ/30V, test the rotation angle and rotor angle (24 points in total every 180 degrees)
Test accuracy ± 2%
|
|
phase shift
|
Sine phase angle, cosine phase angle 13.6 º ± 2 º
|