Rtx-200MS fused silica capillary column low loss GC-MS capillary column

NegotiableUpdate on 03/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Commonly used for analyzing solvents, Freon , Alcohol, ketone, silane, ethylene glycol. Paired with Rtx-5 column for the analysis of phenol, nitroamine, organochlorine pesticides, chlorinated hydrocarbons, chlorinated phenoxyl herbicides, etc., it is used as a confirmation column. Temperature range:- 20 ° C to 340 ° C Equivalent to USP G6 fixed phase replaceable: DB-200, DB-210

Product Details

Rtx ®- 200MSFused silica capillary column - low lossGC-MSMao Xizhu

Commonly used for analyzing solvents,Freon ®Alcohols, ketones, silanes,glycol. giveRtx ®- fiveColumn pairing is used as a confirmation column in the analysis of phenol, nitroamine, organochlorine pesticides, chlorinated hydrocarbons, chlorinated phenoxide herbicides, etc
temperature range: - 20°Carrive340°C.
Equivalent toUSP G6stationary phase
Alternative:DB-200, DB-210

order No#
Llength
inside diameter
thickness
unit
15608
30m
0.25mm
0.10μm
ea.
15623
30m
0.25mm
0.25μm
ea.
15638
30m
0.25mm
0.50μm
ea.
15653
30m
0.25mm
1.00μm
ea.
15609
30m
0.32mm
0.10μm
ea.
15624
30m
0.32mm
0.25μm
ea.
15639
30m
0.32mm
0.50μm
ea.
15654
30m
0.32mm
1.00μm
ea.
Showing 1 to 8 of 8 entries
Commonly used for analyzing solvents,Freon ®Alcohols, ketones, silanes,glycol. giveRtx ®- fiveColumn pairing is used as a confirmation column in the analysis of phenol, nitroamine, organochlorine pesticides, chlorinated hydrocarbons, chlorinated phenoxide herbicides, etc
temperature range: - 20°Carrive340°C.
Equivalent toUSP G6stationary phase
Rtx ®- two hundredIt can complete tasks that other bonding columns cannot analyze and is considered the best choice among inert medium polarity columns. Trifluoropropyl stationary phase can change the distillation order. This is phenyl, cyano, andCarbowax ® What cannot be achieved by a fixed phase.
Rtx ®- two hundredThe fused silica capillary column has good thermal stability, low loss and high inertia, which can be applied toECDNPDandMSDThese high-sensitivity detectors analyze highly active components such as phenol.