SI2103 Ammonia (NH3) Gas Concentration Analyzer

NegotiableUpdate on 02/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
SI2103 Ammonia (NH3) Gas Concentration Analyzer
Product Details

Ammonia gas(NH3)Gas concentration analyzer


Fast, continuous, and real-time measurement

Ultra high sensitivity, precision, and accuracy

● Good long-term stability, no need for frequent calibration

● Measure water(H2O)And carbon dioxide(CO2)To calibrate and validate

● Small size, can be deployed in the field or laboratory, no consumables required

PicarroSI2103The gas concentration analyzer has achieved high-precision and stable ammonia gas analysis(NH3)Measurement. The analyzer has high sensitivity and a detection limit ofpptLevel, high stability, and negligible drift from one month of continuous work. Coating on important gas channels(SilcoNert ®)Can be reducedNH3The adsorption tendency of molecules on the channel surface improves the response time of measurements and eliminates measurement bias. Extra carbon dioxide(CO2)Measurement values are used forproxy authenticationSimplified and replaced the complex calibration process of standard gases (refer to page 2).

For ammonia gas that requires real-time response measurement (Figure)1)And/Or applications with high sensitivity and stability,PicarroAn analyzer is an ideal solution. These applications include but are not limited to urban and atmospheric air quality monitoring, particulate matter formation research, quantification of livestock emissions, quantification of vehicle emissions, indoor air quality, etc. The analyzer has a small size and low power consumption requirements, and can be disassembled and assembled within a few minutes (whether in the laboratory or in the field).

SI2103The analyzer can run for several months without user interaction, and the concentration trend data is continuously archived on the internal hard drive of the analyzer. And it can be achieved through EthernetRS-232Interface, analog signal4~20 mAperhapsModbusAutomatically export measurement data output.

PicarroCavity decay spectroscopy technology(CRDS)It combines many advantages, such as high precision, accuracy, low drift, and ease of use.

Ammonia response time

SI2103 氨气(NH3)气体浓度分析仪

picture1 20 ppbUnder the change of ammonia concentration,SI2103 10~90%and90~10%Typical response time.

SI2103 Performance Specifications

Ensure performance**

Detection lower limit(100 Seconds)

300 ppt

zero drift*50The difference between the maximum values of the minute averages

± 100 ppt

Accuracy(1σ10 s

accuracy1σ100 s

300 ppt

100 ppt

Measurement Interval***

< 4=''>s

Response time(020 ppb(Rising)/fall time10-90%/90-10%

< 1=''>

measuring range

0~10 ppm

*The Picarro analyzer does not require zero point standard gas or zero point reagent kit to operate or meet specifications.

**When conducting span measurements, the measurement interval will be increased to twice the listed parameters.

***Each purchase of an analyzer comes with specifications and a test report (certificate of conformity) for the instrument.

SI2103 Proxy Gas Verification

For any gas phase analyzer, calibrating with ammonia standard gas is extremely challenging. Carbon dioxide(CO2)It is a commercially available gas with an absorption spectrum similar to that of ammonia, thereforeCan be used asverifymeasureExcellent proxy gas for accuracy and linearity. useCO2Okay, yesPicarro SI2103Verify without the need for useNH3Calibrate with standard gas.if requiredunderstandPicarroFor more information on proxy gas verification, please contactPicarroSales representative or application scientist:sales@picarro.com

SI2103 system specifications

measurement

Cavity ring-down spectroscopy CRDS

Measure chamber temperature and pressurestrongcontrol

±0.005℃±0.0002 atm

sample temperature

−10~45℃

Sample flow rate and pressure

make an appointment2 slm760support from underUnder atmospheric pressure600~950support from underair pressure80~127 kPa

Sample humidity

99%Relative humidity(40℃Under non condensing conditions,No need to dry

environmenttemperature

10~35℃When the instrument is working);−10~50℃instrumentstoragetime

environmenthumidity

85%relative humidityUnder non condensing conditions

measureOther gases(Expected accuracy)

H2O< 200=''>10 secCO2< 10=''>10 sec

join in marriagepiece

wrapcontainvacuumPump (external)placekeyboardmouse

Optional: LCD display16roadSilcoNert ®Coating sampler

data output

RS-232EthernetUSBAnalog signal0~10 VModbus4~20 mA(Optional)

Air inlet connector

¼ inchSwagelok ®SSConnector (recommended ¼ inch)OD PFAPipe)

shapesize

Analyzer:43.2(Width) × 21.3(High) × 62(Long)cm, including foot pads

External pump:19(Width) × 10.2(High) × 28(Long)cm

installform

Desktop or19Inch rack mounted chassis

weight

Analyzer < 25 kgThe external pump is6.5 kg

Power requirements

100~240 VAC power;47~63 Hz(Automatic detection); At startup (total)<375 WStable operationgotime120 W(analyzer),150 W(Pump)