hydrogen sulfide(H2S)Gas concentration analyzer
●approveReal time fence line and movementH2SThe measurement
High sensitivity, capable of meeting regulatory requirements
Good stability, continuous operation, minimizing downtime and data loss to the greatest extent possible
● Easy to operate, no consumables required, reducing costs
● Small size, quick installation, simplified new deployment
Picarro SI2104Gas concentration analyzer can provide accurate and real-time hydrogen sulfide(H2S)Observation. The analyzer haspptThe detection limit of the level is low, the size is small, and it is easy to install and use.
SI2104An analyzer is a technically breakthrough instrument that can be deployed on site and can be used for various research purposes, such as monitoring air quality, chimney emissions, and drawing smoke plume maps of hydrogen sulfide emissions.H2SThe smoke plume diagram can be used to indicate the emissions of toxic volatile organic compounds such as benzene, toluene, xylene, and acidic gases from chemical plants. This analyzer can be installed on the factory fence line for fixed monitoring. Or with mobile weather stationsGPSWhen used in conjunction with the system and inverter, it is used for mobile leak detection and investigation.
PicarroThe analyzer is equipped with diagnostic software that can continuously measure and record operating parameters to achieve strict quality control and ensure data integrity. If the analyzer is connected to the Internet,PicarroThe after-sales support department can remotely access it to provide quick support and solve problems.
PicarroPatent based cavity decay spectroscopy technology(CRDS), can ensureSI2104Analyzer implementationpptContinuous monitoring of the lower limit of level monitoring performs better than traditional techniques such as Fourier transform infrared spectroscopy(FTIR)Gas chromatography. Due to the limited optical cavity of the analyzer35 ml, can ensure that the analyzer has a fast gas response time (Figure)1)Low noise and high sensitivity (Figure)2)Such characteristics.
Response time of hydrogen sulfide analyzer
picture1 answerSI2104The analyzer is100 ppbPerform multiple cycle response time tests under changes in hydrogen sulfide concentration. Gas response rate <5 sEnsure that even short-term plumes can be detected.
When measuring the atmosphere, SI2104Performance of

Figure 2 shows the continuous monitoring of hydrogen sulfide in the ambient air for more than 48 hours without zero gas reference and calibration (green line). The high sensitivity of the instrument ensures the detection of any situation exceeding the acute exposure reference level (A-REL, 30 ppb) and chronic exposure reference level (C-REL, 7.1 ppb, California Environmental Health Hazard Assessment Office, USA). The average value of the dataset is 0.31 ppb, with a standard deviation (1 sigma) of 0.12 ppb (5-minute moving average).
SI2104 Performance Specifications |
truePerformance guarantee* |
Low detection limit(3σ,100 second)** |
1 ppb [1.44μg/m3] |
Drift(24 hrs)***(50The difference between the maximum values of the minute averages |
± 2 ppb |
|
Accuracy(1σ,10 second) accuracy(1σ,100 Seconds) |
1.5 ppb 0.5 ppb |
Measurement Interval**** |
< 4 s |
measuring range (Ensure accuracy) |
0~10 ppm |
response time(Rising)/fall time10-90%/90-10%) |
≤10 s(100 ppbUnder changing circumstances |
*The analyzer comes with a test report when it leaves the factory.
**In1 ATM and 25At ℃, convert to μg/m3.
***The Picarro analyzer does not require zero point standard gas or zero point reagent kit to operate or meet specifications.
****When conducting span measurements, the measurement interval will be increased to twice the listed parameters.
SI2104 system specifications | |
measurement |
Cavity ring-down spectroscopy (CRDS) |
Measure chamber temperature and pressurestrongcontrol |
± 0.005℃;± 0.0002 atm |
sample temperature |
−10~45℃ |
Sample flow rate and pressure |
make an appointment0.4 slm(760To), no filtering required600~950support from underair pressure(80~127 kPa) |
Maximum rate of change in ambient temperature |
5 ℃/hr |
Sample humidity |
< 99%Relative humidity(40℃Under non condensing conditions, there is no need for drying |
environmenttemperature |
10~35℃(Instrument operation);−10~50℃(instrumentstoragecondition) |
environmenthumidity |
< 85%relative humidity,Under non condensing conditions |
itsIt measuresgas |
H2O(Typical accuracy: ≤)0.02%Reading) |
join in marriagepiece |
wrapcontain:vacuumPump (external)place)、keyboard、mouse Optional: LCD display(A0901)The16Road sampler(A0311,A0311-S)Rack mounted(A0954) |
data output |
RS-232EthernetUSBAnalog signal0~10 V、Modbus、4~20 mA(Optional) |
Air inlet connector |
¼ inchSwagelok ®SSConnector (recommended ¼ inch)OD PFAPipe) |
shapesize |
Analyzer:43.2(Width) × 21.3(High) × 62(Long) cm, including foot pads External pump: 15.5(Width) × 22(High) × 34.5(Long)cm |
installform |
Desktop or19Inch rack mounted chassis |
weight |
Analyzer <25 kgThe external pump is6.5 kg |
authentication |
CEauthentication |
Power requirements |
100~240 VAC power;47~63 Hz(Automatic detection); At startup (total)<375 WSteady state operation:120W(analyzer),150 W(Pump) |
Application precautions |
We need an air like substrate. equalH2O、CO2andCH4When the concentration is much higher than the normal environmental level, as well as organic compounds including but not limited to ethane, acetylene, and other nitrogen-containing and sulfur-containing compounds, it may interfere with the measurement.H2SThe accuracy is ±3% +Accuracy of gas cylinders. For more details about the experimental conditions, please contact us. |