Phone
15716252111
-
Address
503B, Building 2, No. 1099 Baodai West Road, Hengtang, Suzhou High tech Zone (Huijin Science and Technology Innovation Center)
Suzhou Chuangpu Scientific Instrument Co., Ltd
15716252111
503B, Building 2, No. 1099 Baodai West Road, Hengtang, Suzhou High tech Zone (Huijin Science and Technology Innovation Center)
Second hand Shimadzu AA6300 atomic absorption spectrophotometer
Technical Specifications:
1. Measurement wave: Long range: 185~900nm
2. Monochromator: aberration correction Czerny Turner device
3. Bandwidth: 0.2, 0.7, 0.7L, 2.0L nm (4-speed automatic switching)
4. Detector: Photomultiplier tube (short wavelength range)
5. Flame: Optical Dual Beam
6. Graphite furnace: electronic dual beam
7. Background correction: High speed self absorption (BGC-SR)
8. Number of lamp sockets: 6 lamp sockets, 2 lamps lit simultaneously (1 preheating)
9. Lighting method: emission, NON-BGC,BGC-SR,BGC-D2
10. Software environment: Microsoft Windows 2000TM
Product features:
1. Measurement methods: flame continuous method, flame microinjection method, graphite furnace method
2. Concentration conversion method: Calibration curve (optional 1st, 2nd, 3rd order function) standard addition method/simplified standard addition method (1st order function)
3. Repeated testing: Up to 20 repetitions
4. Display mean, standard deviation (SD), and relative standard deviation (RSD)
5. Exclude outliers based on standard deviation (SD) and relative standard deviation (RSD) values
Note: The safety system of the AA-6300 series uses optical probes. If the installed instrument is close to the window, make sure it is not exposed to too strong outdoor sunlight. Otherwise, the flame monitor may be disturbed while monitoring flame combustion, and the flame extinguishing safety system may not function properly. If incandescent lamps or other heat sources are close to the main unit, it is necessary to confirm that the illuminance is below 400Lx. If unsure, it is necessary to ensure that the light from the light source cannot directly shine into the burner chamber.
Second hand Shimadzu AA6300 atomic absorption spectrophotometer
| Product Number | Product Name | Remarks | Unit to which it belongs |
|---|---|---|---|
| - | Spectrophotometer mainframe | Standard Appendix | |
| 206-52019-94 | STANDARD ACCESORIES | Standard Appendix | Standard Appendix |
| 206-50389-91 | HOSE ASSY,AIR | Rubber sleeve fittings (for air) | Standard Appendix |
| 206-50389-92 | HOSE ASSY,C2H2 | Rubber sleeve fittings (for acetylene) | Standard Appendix |
| 465-06051 | AC CORD 220V VDE | Power cable 220V | Standard Appendix |
| 201-79229-01 | CLEANING WIRE | Cleaning silk | Standard Appendix |
| 037-61019 | HOSE BAND,WIRE 16 | Pipe clamp, 16mm | Standard Appendix |
| 206-52039-91 | SEAL JOINT ASSY | Sealed joint | Standard Appendix |
| 204-05899-01 | TUBE | Injection tube (made of Teflon) | Standard Appendix |
| 206-50772-91 | 206-50772-91 | Injection tube (for organic solvent samples) | Standard Appendix |
| 200-31328-01 | POLYETHYLENE CAPILLARY,NO.3 | Polyethylene capillary tube, No.3 | Standard Appendix |
| 206-52033-92 | DRAIN ASSY | Waste liquid combination | Standard Appendix |
| 016-43201-02 | PE TUBE,8X1 | PE pipe, 8 * 1 (waste pipe) | Standard Appendix |
| 086-03804 | SPANNER,HEX 3 | Hexagonal wrench 3mm | Standard Appendix |
| 206-52046-92 | CARD | There are also English and Japanese versions 206-52046-91 available | Standard Appendix |
| 206-50442-91 | GREASE,IN CUP | Lubricating oil (in a small cup) | Standard Appendix |
| 206-52021-91 | FUNNEL ASSY | Chimney combination | Standard Appendix |
| 202-32982 | EARTH WIRE | ground wire | Standard Appendix |
| 206-52834-91 | CD WIZAARD CN | CD-ROM WizAAr | Standard Appendix |
| 206-50325-91 | CABLE,RS-232C 9PIN | dianlan ,RS-232C,9P | Standard Appendix |
| 062-65055-05 | LAMP,L6380 | Deuterium lamp | Repair and maintenance components |
| 206-52300-91 | NEBULIZER ASSY | Including impact balls | Repair and maintenance components |
| 206-50362-92 | JACKET ASSY | sprayer | Repair and maintenance components |
| 206-50363-91 | CHAMBER ASSY | polypropylene | Repair and maintenance components |
| 206-50370-93 | 10CM BURNER HEAD ASSY | Titanium, 10cm | Repair and maintenance components |
| 206-50762-91 | BURNER HEAD ASSY | Teflon | Repair and maintenance components |
| 035-65268-02 | ELBOW,31020600 | Connect the atomizer to the spray pipe | Repair and maintenance components |
| 036-15551-16 | O-RING,AS568A-116 4D | Used for burner socket (burner head side) | Repair and maintenance components |
| 036-11222 | O-RING,4D P22 | Used for burner socket (atomizer side) | Repair and maintenance components |
| 036-11203 | O-RING,4D P5 | Used for atomization chamber | Repair and maintenance components |
| 036-11217 | O-RING,4D P16 | Used for atomizers, atomization chamber plugs | Repair and maintenance components |
| 036-11215 | O-RING,4D P14 | Used for waste liquid connectors | Repair and maintenance components |
| 036-11237 | O-RING,4D P35 | Used for installing the protective sheath of the atomization chamber | Repair and maintenance components |
| 201-79229-01 | CLEANING WIRE | Used for cleaning capillary tubes | Repair and maintenance components |
| 204-05899-01 | TUBE | Teflon * tube, used for inhaling samples | Repair and maintenance components |
| 206-50772-91 | SAMPLING TUBE ASSY | Polyethylene pipe, used for inhaling samples | Repair and maintenance components |
| 206-52033-92 | DRAIN ASSY | Overflow type waste liquid tank | Repair and maintenance components |
| 206-52342-91 | PE TUBE R | Waste liquid hose (under atomization chamber) | Repair and maintenance components |
| 016-02101-04 | HOSE,8X2B-BK | Used for assisting gas (air), black | Repair and maintenance components |
| 016-02101-03 | HOSE,RUBBER 8X2B-R | Used for gas, red color | Repair and maintenance components |
| 016-02101-01 | HOSE,8X2B-G | Used for assisting gas (N2O), green | Repair and maintenance components |
| 037-61019 | HOSE BAND,WIRE 16 | Hose clamp | Repair and maintenance components |
| 016-43200-08 | TUBE,SUPER-CORN-ACE 9X13 | Waste liquid hose (under atomization chamber) | Repair and maintenance components |
| 016-43201-02 | PE TUBE,8X1 | Waste liquid tube, connected to waste liquid bottle | Repair and maintenance components |
| 204-27570-02 | SEAL JOINT ASSY | Used to check for air leaks | Repair and maintenance components |
| 200-31328-01 | POLYETHYLENE CAPILLARY,NO.3 | Used for sealing capillary tubes | Repair and maintenance components |
| 206-51389 | FIXING PLATE | Used for fixing the atomization chamber | Repair and maintenance components |
| 206-50486 | MIXER | mixing chamber | Repair and maintenance components |
| 206-52046-91 | CARD | Used for cleaning burners and checking burner height | Repair and maintenance components |
| 206-51843 | SET SCREW | Used for fixing hollow cathode lamps | Repair and maintenance components |
| 206-52217 | fixed block | Used for fixing atomizers | Repair and maintenance components |
| 206-50300-93 | HIGH TEMP. BURNER HEAD/AA-6800 | Titanium | Used for flame analysis |
| 8901-58000 | air compressor | Used for flame analysis | |
| 200-64051 | Silent air compressor | Used for 50Hz/60Hz | Used for flame analysis |
| 200-64020 | gas-water separator | Used for flame analysis | |
| 206-52458-91 | MIST SEPARATOR KIT, AA | gas-water separator | Used for flame analysis |
| 040-72020-01 | REGULATOR,YR-71/C2H2 | Acetylene gas is used | Used for flame analysis |
| 040-72019-11 | REGULATOR,MAF-85S/N2O | Nitrous oxide gas is used | Used for flame analysis |
| 206-52100-90 | GFA-EX7I | Graphite Furnace Atomizer ASC-EX7i | Graphite Furnace (ASC-EX7i) |
| 206-50587-11 | High-density graphite tube | High-density graphite tube | Graphite Furnace (ASC-EX7i) |
| 206-50588-11 | Pyrolytic coated graphite tube | Pyrolytic coated graphite tube | Graphite Furnace (ASC-EX7i) |
| 206-50887-02 | PLATFORM TUBE | Platform graphite tube | Graphite Furnace (ASC-EX7i) |
| 206-50100-39 | ASC-6100F | autosampler | autosampler |
| 206-50200-91 | ASK-6100 | Unit for graphite furnace | autosampler |
| 206-52140-91 | KIT FOR FURNACE ASK-6300 | Install component ASK-6300 | autosampler |
| 206-67563 | NOZZLE ASSY,HVG. | Combination of pipe openings, HVG, When using ASC-6100F and HVG-1, it is necessary | autosampler |
| 204-21932-01 | MVU-1A | Mercury generating unit | Other attachments |
| 201-98687 | LONG ABSORPTION CELL | Gas circulation pool for MVU | Other attachments |
| 202-35867 | CELL HOLDER ASSY | Gas circulation pool rack, used for MVU | Other attachments |
| 206-17143- | HVG-1 | hydride generation | Other attachments |
| 8820-AC7000 | Cooling water circulation device CA-1112 | Working temperature range: -10~+40 ℃ | Other attachments |
| 206-84373-91 | COOLER ATTACH KIT | Used for GFA connection CA-1112 | Other attachments |
| 206-86147-91 | REGURATER ASSY | GFA-EX7i tap water cooling pressure reducing valve | Other attachments |
| Product Number | Product Name | Remarks |
|---|---|---|
| 200-38422-02 | Hollow Cathode Lamp, Ag | Hollow cathode lamp silver |
| 200-38422-01 | Hollow Cathode Lamp, Al | Hollow cathode lamp aluminum |
| 200-38422-42 | Hollow Cathode Lamp, As | Hollow cathode lamp arsenic |
| 200-38422-25 | Hollow Cathode Lamp, Au | Hollow cathode lamp gold |
| 200-38422-39 | Hollow Cathode Lamp, B | Hollow cathode lamp boron |
| 200-38422-03 | Hollow Cathode Lamp, Ba | Hollow cathode lamp barium |
| 200-38422-04 | Hollow Cathode Lamp, Be | Hollow cathode lamp beryllium |
| 200-38422-43 | Hollow Cathode Lamp, Bi | Hollow cathode lamp bismuth |
| 200-38422-05 | Hollow Cathode Lamp, Ca | Hollow cathode lamp calcium |
| 200-38422-06 | Hollow Cathode Lamp, Cd | Hollow cathode lamp cadmium |
| 200-38422-09 | Hollow Cathode Lamp, Co | Hollow cathode lamp cobalt |
| 200-38422-07 | Hollow Cathode Lamp, Cr | Hollow cathode lamp chromium |
| 200-38422-27 | Hollow Cathode Lamp, Cs | Hollow cathode lamp cesium |
| 200-38422-60 | Hollow Cathode Lamp, Dy | Hollow cathode lamp dysprosium |
| 200-38422-61 | Hollow Cathode Lamp, Er | Hollow cathode lamp erbium |
| 200-38422-62 | Hollow Cathode Lamp, Eu | Hollow cathode lamp europium |
| 200-38422-10 | Hollow Cathode Lamp, Fe | Hollow cathode lamp iron |
| 200-38422-40 | Hollow Cathode Lamp, Ga | Hollow cathode lamp gallium |
| 200-38422-63 | Hollow Cathode Lamp, Gd | Hollow cathode lamp gadolinium |
| 200-38422-11 | Hollow Cathode Lamp, Ge | Hollow cathode lamp germanium |
| 200-38422-64 | Hollow Cathode Lamp, Hf | Hollow cathode lamp hafnium |
| 200-38422-65 | Hollow Cathode Lamp, Ho | Hollow cathode lamp |
| 200-38422-48 | Hollow Cathode Lamp, In | Hollow cathode lamp indium |
| 200-38422-66 | Hollow Cathode Lamp, Ir | Hollow cathode lamp iridium |
| 200-38422-22 | Hollow Cathode Lamp, K | Hollow cathode lamp potassium |
| 200-38422-29 | Hollow Cathode Lamp, La | Hollow cathode lamp lanthanum |
| 200-38422-30 | Hollow Cathode Lamp, Li | Hollow cathode lamp lithium |
| 200-38422-67 | Hollow Cathode Lamp, Lu | Hollow cathode lamp lutetium |
| 200-38422-12 | Hollow Cathode Lamp, Mg | Hollow cathode lamp magnesium |
| 200-38422-13 | Hollow Cathode Lamp, Mn | Hollow cathode lamp manganese |
| 200-38422-31 | Hollow Cathode Lamp, Mo | Hollow cathode lamp molybdenum |
| 200-38422-14 | Hollow Cathode Lamp, Na | Hollow cathode lamp sodium |
| 200-38422-32 | Hollow Cathode Lamp, Nb | Hollow cathode lamp niobium |
| 200-38422-68 | Hollow Cathode Lamp, Nd | Neodymium hollow cathode lamp |
| 200-38422-15 | Hollow Cathode Lamp, Ni | Hollow cathode lamp nickel |
| 200-38422-69 | Hollow Cathode Lamp, Os | Hollow cathode lamp osmium |
| 200-38422-21 | Hollow Cathode Lamp, Pb | Hollow cathode lamp lead |
| 200-38422-41 | Hollow Cathode Lamp, Pd | Hollow cathode lamp palladium |
| 200-38422-70 | Hollow Cathode Lamp, Pr | Hollow cathode lamp praseodymium |
| 200-38422-20 | Hollow Cathode Lamp, Pt | Hollow cathode lamp platinum |
| 200-38422-33 | Hollow Cathode Lamp, Rb | Hollow cathode lamp rubidium |
| 200-38422-44 | Hollow Cathode Lamp, Re | Hollow cathode lamp rhenium |
| 200-38422-49 | Hollow Cathode Lamp, Rh | Hollow cathode lamp rhodium |
| 200-38422-45 | Hollow Cathode Lamp, Ru | Hollow cathode lamp ruthenium |
| 200-38422-24 | Hollow Cathode Lamp, Sb | Hollow cathode lamp antimony |
| 200-38422-71 | Hollow Cathode Lamp, Sc | Hollow cathode lamp scandium |
| 200-38422-08 | Hollow Cathode Lamp, Cu | Hollow cathode lamp copper |
| 200-38422-46 | Hollow Cathode Lamp, Se | Hollow cathode lamp selenium |
| 200-38422-16 | Hollow Cathode Lamp, Si | Hollow cathode lamp silicon |
| 200-38422-72 | Hollow Cathode Lamp, Sm | Hollow cathode lamp samarium |
| 200-38422-18 | Hollow Cathode Lamp, Sn | Hollow cathode lamp tin |
| 200-38422-34 | Hollow Cathode Lamp, Sr | Hollow cathode lamp strontium |
| 200-38422-35 | Hollow Cathode Lamp, Ta | Hollow cathode lamp tantalum |
| 200-38422-73 | Hollow Cathode Lamp, Tb | Hollow cathode lamp terbium |
| 200-38422-47 | Hollow Cathode Lamp, Te | Hollow cathode lamp tellurium |
| 200-38422-17 | Hollow Cathode Lamp, Ti | Hollow cathode lamp titanium |
| 200-38422-74 | Hollow Cathode Lamp, Tl | Hollow Cathode Lampyour |
| 200-38422-75 | Hollow Cathode Lamp, Tm | Hollow cathode lamp thulium |
| 200-38422-19 | Hollow Cathode Lamp, V | Hollow cathode lamp vanadium |
| 200-38422-36 | Hollow Cathode Lamp, W | Hollow cathode lamp tungsten |
| 200-38422-76 | Hollow Cathode Lamp, Y | Hollow cathode lamp yttrium |
| 200-38422-77 | Hollow Cathode Lamp, Yb | Hollow cathode lamp ytterbium |
| 200-38422-23 | Hollow Cathode Lamp, Zn | Hollow cathode lamp zinc |
| 200-38422-37 | Hollow Cathode Lamp, Zr | Hollow cathode lamp zirconium |
| 200-38431-04 | Hollow Cathode Lamp, Ce | Hollow cathode lamp cerium |
| 200-38431-49 | Hollow Cathode Lamp, Dy | Hollow cathode lamp dysprosium |
| 200-38431-50 | Hollow Cathode Lamp, Er | Hollow cathode lamp erbium |
| 200-38431-55 | Hollow Cathode Lamp, Eu | Hollow cathode lamp europium |
| 200-38431-51 | Hollow Cathode Lamp, Gd | Hollow cathode lamp gadolinium |
| 200-38431-52 | Hollow Cathode Lamp, Hf | Hollow cathode lamp hafnium |
| 200-38431-53 | Hollow Cathode Lamp, Ho | Hollow cathode lamp |
| 200-38431-54 | Hollow Cathode Lamp, In | Hollow cathode lamp indium |
| 200-38431-56 | Hollow Cathode Lamp, Ir | Hollow cathode lamp iridium |
| 200-38431-57 | Hollow Cathode Lamp, Lu | Hollow cathode lamp lutetium |
| 200-38431-29 | Hollow Cathode Lamp, Nd | Neodymium hollow cathode lamp |
| 200-38431-60 | Hollow Cathode Lamp, Os | Hollow cathode lamp osmium |
| 200-38431-61 | Hollow Cathode Lamp, P | Hollow cathode lamp phosphorus |
| 200-38431-59 | Hollow Cathode Lamp, Pr | Hollow cathode lamp praseodymium |
| 200-38431-44 | Hollow Cathode Lamp, S | Hollow cathode lamp sulfur |
| 200-38431-68 | Hollow Cathode Lamp, Sc | Hollow cathode lamp scandium |
| 200-38431-65 | Hollow Cathode Lamp, Sm | Hollow cathode lamp samarium |
| 200-38431-66 | Hollow Cathode Lamp, Tb | Hollow cathode lamp terbium |
| 200-38431-58 | Hollow Cathode Lamp, Th | Hollow cathode lamp thorium |
| 200-38431-46 | Hollow Cathode Lamp, Tl | Hollow Cathode Lampyour |
| 200-38431-69 | Hollow Cathode Lamp, Tm | Hollow cathode lamp thulium |
| 200-38431-70 | Hollow Cathode Lamp, U | Hollow cathode lamp uranium |
| 200-38431-47 | Hollow Cathode Lamp, Y | Hollow cathode lamp yttrium |
| 200-38431-67 | Hollow Cathode Lamp, Yb | Hollow cathode lamp ytterbium |
| 200-81505-27 | Hollow Cathode Lamp, Ag-Zn-Pb-Cd | Composite hollow cathode lamp |
| 200-81505-35 | Hollow Cathode Lamp, Al-Ca-Fe-Mg | Composite hollow cathode lamp |
| 200-81505-07 | Hollow Cathode Lamp, As-Ni | Composite hollow cathode lamp |
| 200-81505-16 | Hollow Cathode Lamp, As-Sb-Bi | Composite hollow cathode lamp |
| 200-81505-17 | Hollow Cathode Lamp, As-Se-Te | Composite hollow cathode lamp |
| 200-81505-28 | Hollow Cathode Lamp, Au-Ag | Composite hollow cathode lamp |
| 200-81505-26 | Hollow Cathode Lamp, Au-Cu-Fe-Ni | Composite hollow cathode lamp |
| 200-81505-08 | Hollow Cathode Lamp, Au-Ni | Composite hollow cathode lamp |
| 200-81505-02 | Hollow Cathode Lamp, Ba-Ca-Sr | Composite hollow cathode lamp |
| 200-81505-12 | Hollow Cathode Lamp, Ba-Ca-Sr-Mg | Composite hollow cathode lamp |
| 200-81505-01 | Hollow Cathode Lamp, Ca-Mg-Al | Composite hollow cathode lamp |
| 200-81505-03 | Hollow Cathode Lamp, Ca-Mg-Al-Li | Composite hollow cathode lamp |
| 200-81505-40 | Hollow Cathode Lamp, Ca-Mg-Sr | Composite hollow cathode lamp |
| 200-81505-36 | Hollow Cathode Lamp, Ca-Mg-Zn | Composite hollow cathode lamp |
| 200-81505-31 | Hollow Cathode Lamp, Co-Ni | Composite hollow cathode lamp |
| 200-81505-39 | Hollow Cathode Lamp, Cr-Co-Cu-Mn-Ni | Composite hollow cathode lamp |
| 200-81505-20 | Hollow Cathode Lamp, Cr-Co-Ni | Composite hollow cathode lamp |
| 200-81505-25 | Hollow Cathode Lamp, Cr-Cu | Composite hollow cathode lamp |
| 200-81505-05 | Hollow Cathode Lamp, Cr-Fe-Mn-Ni | Composite hollow cathode lamp |
| 200-81505-23 | Hollow Cathode Lamp, Cu-Co | Composite hollow cathode lamp |
| 200-81505-37 | Hollow Cathode Lamp, Cu-Fe | Composite hollow cathode lamp |
| 200-81505-09 | Hollow Cathode Lamp, Cu-Ga | Composite hollow cathode lamp |
| 200-81505-32 | Hollow Cathode Lamp, Cu-Ni | Composite hollow cathode lamp |
| 200-81505-42 | Hollow Cathode Lamp, Cu-Ni-Zn | Composite hollow cathode lamp |
| 200-81505-10 | Hollow Cathode Lamp, Cu-Mn | Composite hollow cathode lamp |
| 200-81505-11 | Hollow Cathode Lamp, Cu-Pb-Zn-Ag | Composite hollow cathode lamp |
| 200-81505-13 | Hollow Cathode Lamp, Cu-Zn-Fe-Mn | Composite hollow cathode lamp |
| 200-81505-14 | Hollow Cathode Lamp, Cu-Zn-Mo | Composite hollow cathode lamp |
| 200-81505-21 | Hollow Cathode Lamp, Cu-Zn-Mo-Co | Composite hollow cathode lamp |
| 200-81505-15 | Hollow Cathode Lamp, Cu-Zn-Pb-Cd | Composite hollow cathode lamp |
| 200-81505-06 | Hollow Cathode Lamp, Cu-Zn-Pb-Sn | Composite hollow cathode lamp |
| 200-81505-04 | Hollow Cathode Lamp, Fe-Cu-Mn | Composite hollow cathode lamp |
| 200-81505-30 | Hollow Cathode Lamp, In-Ag | Composite hollow cathode lamp |
| 200-81505-34 | Hollow Cathode Lamp, Mg-Zn | Composite hollow cathode lamp |
| 200-81505-22 | Hollow Cathode Lamp, Mo-Cu-Fe | Composite hollow cathode lamp |
| 200-81505-18 | Hollow Cathode Lamp, Pb-Zn-Ag | Composite hollow cathode lamp |