The Shimadzu Inertsil CN-3 liquid chromatography column is a column with cyanopropyl groups bonded to silica gel, which can be used for reverse phase and normal phase separation modes. In reverse phase mode, due to the presence of carbon nitrogen triple bonds, it has different selectivity from ordinary C18 (Figure 1) and is widely used in drug analysis. In addition, in the normal phase mode, the high-density combination of cyanopropyl groups using * technology has a very high separation selectivity compared to commercially available cyanopropyl chromatography columns (Figure 2).
Product Details

Shimadzu Inertsil CN-3 liquid chromatography column product description

● Matrix 3 series high-purity spherical silicone gel
● Particle size : 3μm, 5μm
● Surface area : 450m2/g
● Micro pore diameter : 100Å (10nm)
● Micropore volume : 1.05mL/g
Chemical bonding groups : Cyanopropyl
● End end sealing : None
● Carbon content : 14%
● USP number : L10

Shimadzu Inertsil CN-3 liquid chromatography column

analytical column
Particle size: 3 μ m Length/Inner Diameter 1.0mm 1.5mm - -
33mm 5020-85331 5020-85341 - -
50mm 5020-85332 5020-85342 - -
75mm 5020-85333 5020-85343 - -
100mm 5020-85334 5020-85344 - -
150mm 5020-85335 5020-85345 - -
250mm 5020-85336 5020-85346 - -
Length/Inner Diameter 2.1mm 3.0mm 4.0mm 4.6mm
33mm 5020-05261 5020-05271 5020-05281 5020-05291
50mm 5020-05262 5020-05272 5020-05282 5020-05292
75mm 5020-05263 5020-05273 5020-05283 5020-05293
100mm 5020-05264 5020-05274 5020-05284 5020-05294
150mm 5020-05265 5020-05275 5020-05285 5020-05295
250mm 5020-05266 5020-05276 5020-05286 5020-05296
Particle size: 5 μ m Length/Inner Diameter 1.0mm 1.5mm - -
33mm 5020-85311 5020-85321 - -
50mm 5020-85312 5020-85322 - -
75mm 5020-85313 5020-85323 - -
100mm 5020-85314 5020-85324 - -
150mm 5020-13712 5020-13710 - -
250mm 5020-85316 5020-85326 - -
Length/Inner Diameter 2.1mm 3.0mm 4.0mm 4.6mm
33mm 5020-05311 5020-05321 5020-05331 5020-05341
50mm 5020-05312 5020-05322 5020-05332 5020-05342
75mm 5020-05313 5020-05323 5020-05333 5020-05343
100mm 5020-05314 5020-05324 5020-05334 5020-05344
150mm 5020-05315 5020-05325 5020-01942 5020-01940
250mm 5020-05316 5020-05326 5020-01943 5020-01941

The standard connector type is 1/16 inch Waters connector screw type. Please consult separately for other types of connectors.

Protection column
target analysis
Internal diameter of chromatographic column
Length Inner diameter Protect the column core
(2)
Protective column set
(2 column cores+1 column sleeve)
Particle size Particle size
3μm 5μm 3μm 5μm
1.0mm 10mm 1.0mm 5020-19219 5020-19218 5020-19269 5020-19268
1.5mm, 2.1mm 1.5mm 5020-19319 5020-19318 5020-19369 5020-19368
2.1mm, 3.0mm 3.0mm 5020-19119 5020-19118 5020-19169 5020-19168
4.0mm, 4.6mm 4.0mm 5020-19019 5020-19018 5020-19069 5020-19068
2.1mm, 3.0mm 20mm 3.0mm 5020-19519 5020-19518 5020-19569 5020-19568
4.0mm, 4.6mm 4.0mm 5020-19419 5020-19418 5020-19469 5020-19468
Protective column sleeve Used for a length of 10mm 5020-08500
Used for a length of 20mm 5020-08550

Note: The connector type is limited to 1/16 inch Waters connector screw type only.

application

Inertsil CN-3 is a chromatographic column with cyanopropyl groups bonded to silica gel, suitable for both reverse phase and normal phase separation modes. In reverse phase mode, due to the presence of carbon nitrogen triple bonds, it has different selectivity from ordinary C18 (Figure 1) and is widely used in drug analysis.
In addition, in the normal phase mode, the high-density combination of cyanopropyl groups using * technology has a very high separation selectivity compared to commercially available cyanopropyl chromatography columns (Figure 2).