Welcome Customer !

Membership

Help

Jinan Haineng Instrument Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products
Product Categories

Jinan Haineng Instrument Co., Ltd

  • E-mail

    China@hanon.cc

  • Phone

  • Address

    4th Floor, Building A3-1, Hanyu Jinggu, No. 7000 Jingshi Road, Jinan City

Contact Now

T920 fully automatic titrator

NegotiableUpdate on 05/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

T920 can meet the analysis requirements in research applications, as well as meet the daily needs of users to analyze a large number of samples. Application areas: food, medicine, disease control, commodity inspection, water treatment, petroleum, chemical, marine, power, environmental protection, new energy, teaching, scientific research and other fields.

Product Details

Titration mode

Acid base acid-base titration
Redox redox titration
Argentometric
Silver titration method

Complexometric titration



Dead-stop titration
dead-stop titrationMeasurement modeMEAS
: MeasurementpH/mV/TCAL
pHcorrect
SETSet endpoint mode
METEqual titration
DET
Dynamic titration


Dosage: Titrate according to a predetermined fixed amount
Cleaning: Automatic cleaning after titration is completed
colorful touch screenIntuitive software icons are used to guide users to access selected operations.Preferred Alternative

The specially designed storage area makes itCommonly used solutions are available at any time.Measurement functionpHValue and

mV
measurecalibrationCan perform electrode calibration,Users can use a buffer solution to pre calibrate the electrode at one or two points. If during the calibration process using buffer solution
pHIf there is an abnormal fault in the electrode, an alarm prompt will appear to avoid continuing to use electrodes with low performance or damaged ones.Service items: During the process of instrument shutdown or reagent replacement, work with the transfer pump or

/
Services related to the lubrication and cleaning of burettes.Real time display of titration curveIf the operation is incorrect, it can be temporarily interrupted and restarted or canceled, which will not cause waste of titration solution or time. After titration, the detailed results are displayed: initialpH/mVTemperature, sample volume/Weight, titration volume, and endpointpH15perhaps

mV
Value. The instrument automatically stores the final dataThe data of a sample.Rich modular designT920

It is a truly modular instrument
,


Both burettes and pipettes can be integrated into the system and configured freely, so it can meet the needs of various laboratories.
Automatic burette5Can install four burettes

1/48000 high-precision burette, 10mL transparent graduated glass burette, and anti-corrosion material four-way valve. Theoretical titration volume is 0.2uL.1Pipette pumpDuring the titration process, auxiliary reagents such as acid acidification and water dilution are often required. useA transfer pump, which can be used simultaneously or separately, can truly achieve automation at every stage of the titration process. During the testing process, simply place the sample and press the button to obtain the final result.
Displacement:

ml

/

secondInner tube: chloroprene rubberReal time graphics
The color touch screen display contains all messages and icons, making the use of the instrument very simple. Titration software guides users in using the instrument through programming, analyzing, and interpreting data at every step.

conform to
30GLP
standard8At different stages of the analysis process, data recording is a fundamental requirement for operating modern laboratory instruments. Therefore, each analysis report of T920 will provide: company/institution and operator, operation date and time, sample number, titration consumption volume, sample volume/weight, required unit expression form (such as%, g/L), etc. In the process of pH correction and standardization of reagents, there is an automatic warning function for abnormal buffer/electrode or titrant, which can avoid errors in experimental operations. The titration program can be password edited to prevent unauthorized personnel from using it.Storage of solutionsMultiple options, users can switch freely and protect them with passwords.Preferred solution: storableindividual


be the first choiceThe plan can be changed freely.Expression of analysis resultsFree choice of units for representing results (such as%, grams)/Rising,


ppm
mol/
L
Wait. )
How to choose and match
T920 basic configuration
10mL burette
Pipette pump

PTFE connecting pipe


Polytetrafluoroethylene anti diffusion pipe mouth
Titration suction/washing tube
Polyvinyl chloride hose
Transfer pump PTFE tailpipe

Titration cup


The following accessories can be selected with electrodes according to specific experiments
PH composite electrode
Composite redox electrode
Karl Fischer dual platinum electrode

Silver combination electrode, etc


Burette matching components (1-4 sets can be installed)
10mL automatic burette with 48000 stepper motor
Anti corrosion four-way valve

Titration suction/washing tube


Polytetrafluoroethylene anti diffusion conveying pipe
Pipette pump matching components (can install 1-5 sets)
Pipette pump
Polyvinyl chloride pipe
PTFE transfer pump tail pipe
Independent analysis platform and automatic sampler kit

(The following two sets are optional)

T9201 independent analysis platform supporting components


Independent Analysis Platform
Propeller agitator
Blender extension line

T9216 16 bit fully automatic sampler


16 positions provided for plastic or glass containers, including 15 working positions and 1 cleaning position. Removable turntable, the container can be adjusted to different heights. The supporting equipment includes: glass mixer, power supply, connecting cable, 100 plastic containers and accessories.
T9216 automatic sampler matching components
16 bit automatic sampler
100 titration cups
Propeller agitator
application area
Pharmaceutical industry:
Penicillin antibiotic content, purity of sodium cyclamate, purity of quinine sulfate, and phenol content.
Water quality analysis:
Hardness measurement (Ca2+/Mg2+), chloride ion content measurement, pH value measurement, acid/alkali reactivity (p -/m - value), etc.
Petroleum products:
AN/TAN (acid value/total acid), BN/TBN (base value/total base), bromine number/bromine index, thiol sulfur determination, chloride ion content, etc.

Food industry: acid content in food, chloride ion content in food, citric acid in beverages, sugar content in fruit juice, monosodium glutamate content in seasonings, amino acid content in oral liquids, etc.



Tobacco industry: determination of acid value of essence

Quality inspection of cigarette paper and determination of reducing sugar

Testing of triacetate glycerol and determination of chlorine content in tobacco.

Chemical fiber industry: determination of carboxyl end group content

Acid value, saponification value, hydroxyl value, iodine value, epoxy value, chlorine content in epoxy resin, etc.

Function Parameter

Optional hardware devicesMobile mercury

correct

Burette drivercorrect

T9216

autosampler

correctT9201Independent Analysis Platform

correct

Measurement modeMEAS

: Measurement

pH/mVcorrect

SET

Set endpoint modecorrect

MET

Equal titrationcorrectDETDynamic titration

correct

CAL

pHcorrect

correct

Automatic burette

Number of titration controls used1-4

One (built-in, plug and play)

Pipette pump

16Used for adding auxiliary reagents151-51One (built-in, plug and play)

injector

digit

Position(

A sample,

A cleaning position

cleaning method

Alternating cleaning, single cleaning, no cleaning

Titration cup capacity

150ml

30mixing method

Used for stirring samples

Propeller mixing

method

The number of functional parameters in each method

One (added arbitrarily)

15Emergency sample queue insertion function

have

Queuing function for different sample serieshave

Quantity of samples in each sample series

30individual

Number of methods provided by Hai Neng

>20individual

2Number of methods saved

individual

1Electrode interface type

mv/pH

1Measurement electrode interface

individualPolarized electrode interface

2individual

Reference electrode interface

individualPT1000Temperature electrode interfaceindividual

1Various communication interfaces

RS232standardCOM

1opening

individual

1host

USBinterface

1individual

Blender interfaceindividual

1TTL I/O

interface

1individual

RS485

interfaceindividual

power interface

individualTechnical Parameter

mV/pH

Potential measurement electrode interface

measuring range

±

3,000 mV -19.99~19.99 pH

resolution

0. 1 mV 0.01 pHPossible errors0.2 mV 0.02pH 200 Polarized electrode interfacemeasuring range

±

2,000 mV / 0μ

A

resolution0.1 mV/ 0.1μ

APossible errors

0.2 mV/ 0.3

μA

PT 1000

0.1 Temperature electrode interface

measuring range

0.2 0-110

resolution

0.2 Possible errors

Burette driver

1610 mL100Resolution of burette

μ

L .1/48,000

The time for emptying and filling the buretteSecond(%Liquid filling speed

Control terminal

5.7Control terminalcolorful touch screen+

key

screen displayInch color

TFT

displayresolution320 x 240pixelThe size of the titrator

longx

wide

15 x

High (standard configuration)

make an appointment