Product use
The DT (S) S238-7 series three-phase rail type electronic energy meter is a new product launched by our company. It adopts advanced dedicated bidirectional energy measurement digital circuit chips and SMT manufacturing technology, used to measure active or reactive energy in three-phase AC circuits. It uses a counter display and is characterized by bidirectional power measurement technology, anti-theft, high precision, high reliability, high overload, low power consumption, light weight, and low cost. Adopting 35mm DIN standard rail installation, in compliance with DINEN50022 standard. 7-pole width (module 12.5m), in compliance with JB/T7121-1993 standard. Widely used in circuit breaker installation boxes and complete sets of equipment.
This product is suitable for use in environments with temperatures ranging from 0-40 ° C to+75 ° C and relative humidity not exceeding 85%.
This product meets all technical requirements for three-phase electronic energy meters in GB/T17882-1999 and GB/T17215.321-2008 standards.
Product features
Bidirectional active energy meter, does not require calibration for long-term operation
Three phase power supply, one or two phases of power outage, measurement accuracy is not affected
Wide voltage, current, and operating temperature range
5+1 step counter display or 5+1 6+1 5+2 LCD digital display
Start
Under the conditions of rated voltage, rated frequency, and power factor of COS Φ=1, when the load current is active ≥ 0.002Ib (connected through a transformer), non active ≥ 0.003Ib (connected through a transformer), active ≥ 0.004IB (directly connected), and reactive ≥ 0.005Ib (directly connected), the energy meter should be able to continuously measure electrical energy.
Defluction
When the circuit is disconnected with 115% rated voltage and current applied, the test output of the energy meter should not generate more than one pulse.
Principle and function
As shown in Figure 1, the measured three-phase voltage and current are converted into appropriate levels by their respective sampling circuits and input into a dedicated digital integrated circuit for bidirectional energy metering. The output of the circuit is a pulse signal proportional to the measured input active/reactive power, which is divided and used to drive the distributed motor meter for active/reactive power measurement, achieving three-phase energy metering. The electric energy meter has electric energy testing pulses and outputs.
This meter is powered by a three-phase power supply, and can still operate normally in the event of a phase loss (with the phase loss indicator light off indicating phase A, phase B, and phase C, respectively).
Figure 1DT (S) S/DXS238 series three-phase electronic energy meter working principle block diagram
Usage method
DT(S)S/DXS238The terminal socket wiring of the series three-phase electronic energy meter is shown in the following figure:
|
(1)DTSDirect wiring diagram of three-phase four wire electronic energy meter |
|
(2)DTSThree phase four wire electronic energy meter with current transformer wiring diagram |
|
|
|
|
|
(3)DSSDirect wiring diagram of three-phase electronic energy meter |
|
(4)DSSThree phase three wire electronic energy meter with current transformer wiring diagram |
|
|
|
|
|
(5)DSSThree phase three wire electronic energy meter with current transformer wiring diagram |
|
(5)Schematic diagram of electrical energy test output |
|
|
|
|
|
connecting terminal |
describe |
|
L1 |
L1phase line(A(Xiang) |
|
L2 |
L2phase line(Beach other) |
|
L3 |
L3phase line(Ceach other) |
|
N |
neutral line(zero line) |
|
15and16 |
Passive remote control power pulse output(This feature can be customized forAMR) |
|
7and8 |
Passive short-range electrical energy pulse output |
|
9.11and13 |
Voltage function terminal, only used when the electric energy meter is connected through a current voltage transformer |
Installation and use
Installment and use
Rated frequency: 50Hz/60Hz
Power consumption: Voltage circuit ≤ 1W and 10VA (single-phase)
Power consumption:Current circuit ≤ 1VA (single-phase)
Environmental conditions: calibrated working temperature -25~+55 ℃
Environmental conditions: Maximum operating temperature -40~+70 ℃
Environmental conditions: Relative humidity ≤ 85%
Net weight: Three phase three wire approximately 0.6kg Three phase four wire approximately 0.7kg
|
productmodel
|
accuracygrade
|
specifications |
Electric energy testingPulse constant
|
|
|
DT(S)S238-7 |
Merit 1.0 |
DSS238-7 three-phase three wire 3X100V 3X380V |
3X1.5(6)A |
The pulse constant is based on the energy meter panel representation |
|
3X5(20)A |
||||
|
3X10(40)A |
||||
|
3X15(60)A |
||||
|
3X20(80)A |
||||
|
DTS238-7 three-phase four wire 3X220/380V |
3X1.5(6)A |
|||
|
3X5(20)A |
||||
|
3X10(60)A |
||||
|
3X57.7/100V |
3X20(80)A |
|||
|
3x57.7/100v |
3x1.5(6) |
|||
Basic error
Active power level 1.0, reactive power level 2.0