Second hand Agilent 1100 liquid chromatograph
The exterior design of Agilent 1100 series components has flexible and versatile combination methods; System performance indicators; A graphical workstation friendly interface; The intelligent maintenance system and comprehensive regulatory certification functions, as well as the launch of new components, make Agilent liquid chromatography stable.
The capillary liquid phase pump system controlled by an electronic flow control valve (EFC) has high accuracy and a wide flow rate range. The column flow rate range is 1-20ul/min; 10-100ul/min (optional)
0.001-2.5m/min (EFC closed state)
High pressure preparation pump system, unit or dual high-pressure preparation pump
Flow rate range: 0.001-100m1/min
● Flow rate range of analytical pump system:
Unit pump: 0.001-10m3/min, binary pump: 0.001-5m3/min, quaternary pump: 0.001-10m3/min
Agilent 1100 series injection system with a complete range of varieties
Standard manual sampler (analytical or preparation type)
● Standard automatic sampler
Sample bottle capacity: up to 100 pieces (2mlx100)
Injection volume: 0.1-100ul (0.1-1800ul) optional
● Micro disc automatic sampler
Sample bottle capacity: 2x96 (orifice plate), 2x386 (orifice plate) or 100x2ml
Injection volume: 0.1-100ul (standard part) 0.1-1500ul optional
● Micro standard automatic sampler/micro disc automatic sampler
Injection volume: 0.01-8ul (standard); 0.01-40ul (optional)
● Constant temperature standard automatic sampler/micro disc automatic sampler
Temperature range: 4-40 ℃ with adjustable step size of 1 ℃
220 type microporous plate automatic sampler - combined chemical sample management system
Sample bottle capacity: 12 microporous plates (96 well plate, 384 well plate) for various specifications of test tubes
Injection volume: 0.1-5ul; 0.1-20ul
Variable wavelength scanning ultraviolet detector (VWD) wavelength range: 190-600nm
Multi wavelength detector (MWD) wavelength range: 190-950nm (dual lamp source)
● Diode Array Detector (DAD)
Second hand Agilent 1100 wavelength range: 190-950nm (dual light source)
Fluorescence detector (FID) excitation wavelength: 200-700nm; emission wavelength: 280-900nm; spectral storage: full spectrum
Differential Refraction Detector (RID) Temperature Control: Room Temperature+5 ℃ -55 ℃ Built in Automatic Purging Valve and Automatic Solvent Circulation Valve
Electrochemical detector (ECD)
LC/MS quadrupole mass detector (MSD)
LC/MS ion trap mass detector (Trap MSD)
Used Agilent 1100 column temperature box and deaerator components
● Column temperature range: 10 ℃ -80 ℃ at room temperature Optional: Column switching valve
Vacuum online deaeratorAgilent