VHJ high-efficiency V-type mixer mixing cylinder structure *. High mixing efficiency, *, made of stainless steel material, polished inner and outer walls, beautiful appearance, uniform mixing, wide applicability, and can be matched with a forced mixer according to user requirements, suitable for mixing finer powder particles, chunks, and materials containing certain moisture.
VHJ high-efficiency mixermaintenance and repair
1. During the production process, it is necessary to regularly check the temperature rise of the bearings. When the temperature rise exceeds 50 ℃, the machine should be stopped for inspection to identify the cause and eliminate the fault.
2. When the new machine is running, the transmission belt is prone to elongation, and attention should be paid to adjusting the appropriate tightness of the belt to ensure its working life.
3. Fragile parts should be regularly inspected and replaced in a timely manner to ensure production quality and quantity.
4. Blades and liners should be regularly checked for wear. If wear occurs, productivity will decrease and particle size will become coarser. If wear is detected, it should be replaced immediately.
5. The host and graded flow bearings are lubricated with grease, using special grease No. 2 with a degree of 265-295.
6. The grease replacement period for bearings is 2000 hours, and the filling amount of lubricating grease should be 1/2 (top measurement) or 3/4 (bottom measurement) of the space inside the bearing cavity. Do not fill too much lubricating grease, otherwise it will cause the bearing temperature to be too high.
7. The grease replacement period for the spiral feeder is 4000 hours, and ordinary calcium based lubricating grease is added.