VMA0055 far exceeds the measurement capability of ± 50 volts/mA of MFT basic units and has its own independent power supply, so is the issue of commonalities a problem.

Product Details

VMA module
MFT4000 series calibration for voltage, current measurement and simulation, and 24 VDC isolated loop power supply

VMA00551

MFT4000 series calibrator for voltage, current measurement and simulation, and 24 VDC isolated loop power supply. The VMA0055 is a DC voltage and current measurement and simulation module used with the Meriam MFT4000 series multifunctional tester. The module utilizes the remarkable multifunctional capabilities of DVM and loop calibrator. When used in conjunction with other MFT functions, the VMA/MFT combination provides valuable functionality that is not available on other devices.

The measurement range includes ± 500 mV, ± 55 V, and ± 100 mA. The source function includes 0-24 V and 0-22 mA. When connected to a loop, it can also be used to temporarily provide 24V DC loop power during debugging, interruption, or calibration activities. The VMA module without power devices can also simulate transmitter output.

VMA0055 far exceeds the measurement capability of ± 50 volts/mA of MFT basic units and has its own independent power supply, so is the issue of commonalities a problem.

The certifications available include:

ce mark

NIST Traceability - Standards

Intrinsic Safety - MET Laboratories per CSA C22.2&UL 913 Class I Division I, Groups A, B, C&D

authentication

Intrinsic safety certification from MET laboratory. MET Laboratory is a nationally recognized testing laboratory (NRTL). This module is certified by MET laboratory and meets the standards CSA C22.2 No.1010.1, CSA C22.2 No. 157-92, and UL913 Fifth Edition Rev 2/21/97 for Class I, Division I, Groups A, B, C, and D, T5 Dangerous areas. Limitations - See detailed information and intrinsic safety control diagrams attached to each MFT modular calibrator.

VMA0055Specification for resolution, range, and measurement accuracy of modules

Environmental temperature range: -10 ℃ to+50 ℃ (+14 ℉ to 122 ℉)

Accuracy declaration for ambient temperatures of 28 ℃ and 18 ℃ (64.4 ℉ to 82.4 ℉)

Apply ambient temperatures of 28 ℃ (82.4 ℉) with a temperature coefficient below 18 ℃ (64.4 ℉) and above

VMA0055 DC current (mA) measurement and source mode

specifications Measurement mode Source mode (no external power supply required)
resolution .001 mA .001 mA
range ± 100.000 mA (55 Vdc compliant) 0-22.000 mA (see Note 3 below)
accuracy ± (0.01% reading+0.015% FS) ± (0.01% of reading+0.015% FS)
open circuit voltage 24 VDC
output drive 15 VDC minimum @ 24 mA, resistive load
temperature coefficient ± (0.001% reading+0.002% FS)/° C ± (0.003% Rdg +0.003% FS) / °C

VMA0055 volt DC measurement and source mode

specifications Measurement mode Source mode (no external power supply required)
resolution 1/100000 Count:. 001 mV;. 001 V 1/100,000
range 500 mV; 1, 2, 4, 8, 15, 30, 55 V 0 – 24.000 VDC
accuracy ± (0.025% reading+0.005% FS) ± (0.01% reading+0.05% FS)
open circuit voltage 24 VDC
output drive 15 VDC minimum @ 24 mA, resistive load
temperature coefficient ± (0.001% reading+0.0015% FS)/° C ± (0.0025% reading+0.0035% FS)/° C
2-wire transmitter simulation mode
specifications Simulation (external power supply)
resolution .001 mA
range 0 – 24.000 mA
accuracy ± (0.01% reading+0.015% FS)
Circuit voltage limit 1 VDC minute, 55 VDC maximum
temperature coefficient ± (0.003% reading+0.003% FS)/° C
Circuit power mode
specifications regulated power supply
range 24 VDC
open circuit voltage 24 VDC
output drive 15 VDC minimum @ 24mA, resistive load

matters needing attention:

1. The nominal resistance of the current terminal in VMA is 10-15 Ω

2. The output load line is linear

3. The derating of the operating time of high-temperature and high current units is as follows:

-Continuous operation @ 50 ℃ to 20mA

-10 minutes typical @ 50 ° C and 24 milliamps (device will be turned off to prevent thermal damage)

ordering information

VMA0055-11-1 VMA module

accessory

P/N A900529-00015: VMA test line kit: 9 "protruding banana plug (both ends), various connectors (for output and analog functions)