Phone
13063859407
-
Address
No. 188 Wanchen Road, Wangting Town, Xiangcheng District, Suzhou City, Jiangsu Province
Suzhou Taxing Boiler Co., Ltd
13063859407
No. 188 Wanchen Road, Wangting Town, Xiangcheng District, Suzhou City, Jiangsu Province

List of Technical Parameters for Vertical Fuel (Gas) Heating Furnaces with a Capacity of 15-2.5 Million kcal/h
List of technical data for 150000-2500000 calorie/h Vertical oil fuel (gas) heating furnace
Project/Data/Model |
YY(Q)L 180Y(Q) |
YY(Q)L 300Y(Q) |
YY(Q)L 350Y(Q) |
YY(Q)L 600Y(Q) |
YY(Q)L 850Y(Q) |
YY(Q)L 1200Y(Q) |
YY(Q)L 1400Y(Q) |
YY(Q)L 1800Y(Q) |
YY(Q)L 2400Y(Q) |
YY(Q)L 3000Y(Q |
|
Rated thermal power KW (10000 kcal/h) |
180 50 |
300 25 |
350 30 |
600 50 |
850 75 |
1200 100 |
1400 125 |
1800 150 |
2400 200 |
3000 250 |
|
Functional fuel |
Light oil, natural gas, low calorific value coal gas, and suitable industrial combustible release gas that can be co fired |
Light oil, heavy oil, natural gas, low calorific value coal gas, and suitable industrial combustible release gas that can be co fired |
|||||||||
Thermal efficiency% ≥ |
80∽88 |
||||||||||
Design pressure MPa |
1.0 |
||||||||||
Maximum working temperature ℃ |
350 |
||||||||||
Furnace content oil quantity m3
|
0.07 |
0.14 |
0.24 |
0.4 |
0.52 |
0.76 |
0.95 |
1.48 |
2 |
2.3 |
|
Circulating oil quantity m3/h |
20 |
40 |
40 |
80 |
80 |
100 |
100 |
100 |
200 |
200 |
|
Pipe connection diameter DN |
50 |
65 |
100 |
100 |
100 |
125 |
125 |
125 |
150 |
150 |
|
|
Full system installed capacity KW
|
oil | 11 |
14 |
14 |
22 |
22 |
40 |
40 |
40 |
66 |
70 |
| gas | 11 |
17 |
17 |
27 |
40 |
40 |
42 |
45 |
70 |
70 |
|
|
External dimensions
mm |
A |
900 |
1100 |
1250 |
1300 |
1570 |
1800 |
1860 |
2000 |
2200 |
2400 |
L1 |
2300 |
2350 |
3600 |
3800 |
4450 |
4895 |
5400 |
6320 |
6420 |
6520 |
|
L2 |
1470 |
1570 |
2090 |
2580 |
2870 |
3325 |
3800 |
4680 |
4790 |
4890 |
|
L3 |
160 |
160 |
160 |
160 |
180 |
200 |
200 |
400 |
450 |
450 |
|
L4 |
1800 |
1900 |
2000 |
2500 |
2820 |
3795 |
4400 |
5050 |
5100 |
5400 |
|
H1 |
1838 |
1890 |
2500 |
3020 |
3350 |
3795 |
4300 |
5346 |
5446 |
5546 |
|
H2 |
1000 |
1080 |
1220 |
1225 |
1380 |
1500 |
1550 |
1600 |
1700 |
1800 |
|
H3 |
600 |
750 |
820 |
780 |
1000 |
1100 |
1250 |
1250 |
1300 |
1400 |
|
H4 |
660 |
800 |
825 |
835 |
1300 |
1420 |
1450 |
1550 |
1620 |
1720 |
|
Total weight of equipment |
1.30 |
1.71 |
2.38 |
3.10 |
4.43 |
6.10 |
7.20 |
9.40 |
11.40 |
13.80 |
|
|
Basic size mm
|
φ1 |
1226 |
1430 |
1580 |
1630 |
1910 |
2220 |
2220 |
2380 |
2600 |
2800 |
φ2 |
965 |
1170 |
1300 |
1350 |
1640 |
1890
|
1940 |
2100 |
2300 |
2500 |
|
φ3 |
- |
- |
- |
- |
- |
- |
- |
1700 |
1900 |
2100 |
|
H |
- |
- |
- |
- |
- |
- |
- |
450 |
450 |
450 |
|
Explanation: Due to the updates and progress of the product, the data in the table above is for reference only. The actual data will be clarified in technical and business negotiations
Explanation:because of update and progress of product,the data in above list is used for reference only.
Acutural data will be affirmed during the period of business talks.
List of technical data for vertical fuel and gas furnaces with a capacity of 3-12.5 million kcal/h
List of technical data for 3000000-12500000 calorie/h vertical oil fuel (gas) heating furnace
Project/Data/Furnace Type |
YY(Q)L-3500Y(Q) |
YY(Q)L-4600Y(Q) |
YY(Q)L-6000Y(Q) |
YY(Q)L-7000Y(Q) |
YY(Q)L-9400Y(Q) | YY(Q)L-12000Y(Q) |
YY(Q)L-14000Y(Q) |
YY(Q)L-14500Y(Q) |
|
rated power |
KW |
3500 |
4600 |
6000 |
7000 |
9400 |
12000 |
14000 |
14500 |
| 10000 kcal/hour | 300 |
400 |
500 |
600 |
800 |
1000 |
1200 |
1250 |
|
Design pressure MPa |
1.0 |
1.10 |
1.3 |
||||||
Maximum working temperature ℃ |
350 |
The temperature for using thermal oil is 350 ℃, and for using biphenyl it is 385 ℃ |
|||||||
Thermal efficiency% ≥ |
83-88 |
88-90 |
|||||||
Fuel used |
Light oil, heavy oil, residual oil, natural gas, low calorific value coal gas, suitable industrial combustible release gas that can be co fired, etc
|
Heavy oil, residual oil, natural gas, low calorific value coal gas, suitable industrial combustible release gas that can be co fired, etc
|
|||||||
Furnace content oil quantity m3
|
2.8 |
4.8 |
6.8 |
8.9 |
12.9 |
17 |
25 |
28 |
|
Circulating oil quantity m3/h |
200 |
260 |
260 |
300 |
400 |
600 |
750 |
800 |
|
Pipe connection diameter DN |
150 |
200 |
200 |
250 |
250 |
350 |
350 |
400 |
|
Dimensions mm |
φA |
2500 |
2800 |
3000 |
3200 |
3500 |
3860 |
3960 |
4150 |
B1 |
1700 |
1850 |
1950 |
2050 |
2200 |
2360 |
2410 |
2500 |
|
B2 |
1350 |
1500 |
1600 |
1670 |
1820 |
2000 |
2050 |
2150 |
|
B3 |
2320 |
2470 |
2570 |
2670 |
2820 |
3050 |
3100 |
3200 |
|
C |
6100 |
6900 |
7800 |
8500 |
10200 |
12200 |
14000 |
15000 |
|
H1 |
7200 |
8000 |
8900 |
9600 |
11400 |
13400 |
15200 |
16200 |
|
H2 |
8300 |
9100 |
10000 |
10900 |
12600 |
14700 |
16500 |
17500 |
|
Total weight of equipment in tons |
17 |
22 |
29 |
41 |
54 |
70 |
85 |
90 |
|
Basic size mm |
φ1 |
2563 |
2863 |
3075 |
3300 |
3600 |
3700 |
3700 |
3700 |
φ2min |
3500 |
3800 |
4400 |
4800 |
5500 |
6860 |
7460 |
7650 |
|
h |
8 |
12 |
12 |
18 |
18 |
24 |
24 |
24 |
|
install equipment electric power |
Fuel KW |
85 |
85 |
100 |
100 |
150 |
255 |
310 |
355 |
Gas KW |
85 |
85 |
100 |
100 |
150 |
235 |
295 |
335 |
|
Explanation: Due to the updates and progress of the product, the data in the table above is for reference only. The actual data will be clarified in technical and business negotiations