Welcome Customer !

Membership

Help

Shanghai Baihe Instrument Technology Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Shanghai Baihe Instrument Technology Co., Ltd

  • E-mail

  • Phone

    1316612105513817307074

  • Address

    Building A, Cangyuan Science and Technology Park, 951 Jianchuan Road, Minhang District, Shanghai

Contact Now

X-ray flaw detector

NegotiableUpdate on 02/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product Code: XXG-2505 Product Model: XXG-2505 Type Category: Non destructive testing equipment - X-ray testing equipment (RT) Brand: Olympus Purpose: Non destructive testing Application field: Metal Production unit: X-ray flaw detector XXG-2505 is used for national defense, shipbuilding, petroleum, chemical, mechanical, aviation and aerospace industries

Product Details

XX-ray flaw detectorXXG-2505This type is used in industrial sectors such as national defense, shipbuilding, petroleum, chemical, mechanical, aerospace, and construction to inspect the quality of materials, parts, processing and welding, internal defects, and processing of various light metals, rubber, ceramics, etc. for ship hulls, pipelines, high-pressure vessels, boilers, aircraft, vehicles, and bridges.

1X-ray flaw detectorXXG-2505Type technical parameters:

1Output voltage:150250KV, continuously adjustable;

2Tube current:5mA

3Focus size:2.0×2.0mm

4Radiation angle 405°;

5Focal length600 mm ,time of exposure5minDouble sided lead foil enhances sensitivity;

6Sensitivity:1.5%;

7Film density:D1.5

8Maximum penetration power:40mm(A3steel)

9Generator size: 320×320×655mm; Weight:30KG

10Controller size:365×310×225mm; Weight:18KG

IIX-ray flaw detectorXXG-2505Characteristics of Type:

1Can be configuredT4523T4525controller;

2XSmall size of radiation generator,Anode grounding,Fan forced cooling;

3Lightweight,be easy to carry about,Easy to operate;

4, Press1:1Work and rest methods;

5Strictly control the production process and ensure a beautiful appearance,Reasonable structure;

6Automatic trainingXRadiation generator,Query exposure parameters;

7Delay starting high voltage to ensure operator safety.

IIIX-ray flaw detectorXXG-2505Type configuration:

1Directional ceramicsXX-ray tube

2Generator

3Connecting cables

4Controller

5Power cable

6Grounding wire

7Including alarm lights1individual

8Lead type1box

9Film hidden bag5individual

10Enhanced sensitivity screen5individual

11Transmittance meter1set

12Fuse1set