Universal protection and measurement device
|
301T
|
Current protection (three-stage overcurrent, definite time limit, inverse time limit, negative sequence current, overload, zero sequence current, compound voltage overcurrent, Ix overcurrent protection), reclosing (with no voltage detection, synchronous detection, and post acceleration), low-frequency load shedding protection (with slip locking), low-frequency disconnection protection, voltage protection (low-voltage disconnection, low voltage, overvoltage, loss of voltage, negative sequence overvoltage, zero sequence voltage), small current grounding protection, backup automatic switching, starting reclosing, manual acceleration after closing, motor (including protection for long starting time, overheating protection, and current setting doubling), reverse power, non electric quantity protection (including heavy gas, light gas, high oil temperature, and oil temperature over) High)
|
Note 1: Inverse time limit includes IEC standards
Three characteristic curves of inverse time: standard inverse time, extraordinary inverse time, and extreme inverse time.
Note 2: If the non electric quantity protection function is activated, the designated input ports are for each non electric quantity based on the type of non electric quantity protection activated.
|
|
Automatic backup power input device
|
331A
|
Current protection (current quick break, overcurrent, zero sequence current), reclosing (with rear acceleration), comprehensive backup automatic switching.
|
Specially designed for segmented protection, measurement and control of busbars with voltage levels of 66KV and below, automatic switching of backup power supply, automatic switching of incoming line backup and busbars backup.
|
|
Asynchronous motor comprehensive protection and measurement device
|
362A
|
Longitudinal differential protection (differential quick break, ratio differential<with CT disconnection interlock>, differential current over limit warning), magnetic balance differential protection, current protection (three-stage overcurrent, timed limit, inverse time limit, stage II negative sequence overcurrent, overload, zero sequence current), voltage protection (overvoltage, low voltage), overheating protection, long start-up time protection, non electric quantity protection (including non electric quantity one and non electric quantity two). With CT disconnection locking>
|
Note 1: Inverse time limit includes IEC standards
Three characteristic curves of inverse time: standard inverse time, extraordinary inverse time, and extreme inverse time.
Note 2: If the non electric quantity protection function is activated, the designated input ports are for each non electric quantity based on the type of non electric quantity protection activated.
|
|
Generator comprehensive protection measurement and control device
|
363A
|
Longitudinal differential protection (differential quick break, ratio differential<with CT disconnection interlock>, differential current limit warning), transverse differential protection, current protection (II composite voltage overcurrent, zero sequence overcurrent, overload, II section negative sequence overcurrent), voltage protection (zero sequence voltage, overvoltage), reverse power protection, low-frequency disconnection protection, low excitation demagnetization protection. With CT disconnection locking>
|
Suitable for comprehensive protection of electric motors in non directly grounded power grids with voltage levels of 66KV and below.
|
|
Voltage Transformer Protection and Measurement Device
|
381A
|
Voltage protection (overvoltage, low voltage, negative sequence voltage, zero sequence voltage), PT parallel function.
|
Dedicated to the protection and measurement of voltage transformers, one device can complete the protection and measurement of two voltage transformers with segmented single busbar connection.
|
|
Transformer backup protection measurement and control device
|
391A
|
IV section compound voltage lockout directional overcurrent protection (with directional lockout, voltage lockout, negative sequence voltage lockout), overload protection, main transformer cold air protection, overload lockout voltage regulation protection, zero sequence overvoltage protection, II section zero sequence overcurrent protection.
|
Dedicated to backup protection for two or three coil transformers with voltage levels of 66KV and below.
|
|
Transformer differential protection device
|
392A
|
Differential quick break protection, ratio differential protection, differential current over limit alarm, medium voltage side overcurrent protection, low voltage side overcurrent protection, non electric quantity protection.
|
A two or three coil transformer main protection device specifically designed for voltage levels of 66KV and below, mainly used for differential, gas, and temperature protection of the main transformer.
|
|
Transformer measurement and control device
|
393A
|
High voltage side three-phase measurement current (Ia1, Ib1, Ic1), high-voltage side three-phase phase voltage (Ua1, Ub1, Uc1), high-voltage side three-phase line voltage (Uab1, Ubc1, Uca1), low-voltage side three-phase measurement current (Ia2, Ib2, Ic2), low-voltage side three-phase phase voltage (Ua2, Ub2, Uc2), low-voltage side three-phase phase voltage (Uab2, Ubc2, Uca2), frequency (F)
High voltage side active power (P), reactive power (Q), high voltage side active power (PW), reactive power (QW), low voltage side active power (P2), reactive power (Q2), low voltage side active power (PW2), reactive power (QW2)
8-way relay remote control output
|
Suitable for measuring and monitoring two coil transformers with voltage levels of 66KV and below.
|