-
E-mail
xizidb@126.com
- Phone
-
Address
No. 8 Zhuantang Science and Technology Park, Zhuantang Street, Xihu District, Hangzhou City, Zhejiang Province
Hangzhou Xizi Group Co., Ltd
xizidb@126.com
No. 8 Zhuantang Science and Technology Park, Zhuantang Street, Xihu District, Hangzhou City, Zhejiang Province

XPD601L-3N three-phaseNetwork (multifunctional) power meter,It is designed for the power monitoring needs of power systems, industrial and mining enterprises, public facilities, and intelligent buildings. It integrates programmable power measurement, digital communication, and multiple input and output functions, and can measure various commonly used power parameters, such as three-phase voltage, current, active power, reactive power, active energy, reactive energy, harmonics, extreme values, demand, complex rates, etc. It also has multiple expansion modules: digital communication module, digital switch module, power pulse module, analog transmission output module, harmonic measurement module, which can be flexibly selected according to needs. All data can be accessed throughRS485Communication orMODBUSCommunication protocol reading, switch input can be used to monitor the status of switches; The output of the switch quantity can be remotely controlled and triggered with an over limit alarm; The analog transmission output function can replace traditional transmitters.XZThe series of network (multifunctional) power instruments can adapt to all voltage levels and wiring methods, and meet the distribution and centralized control methods of various specifications of high and low voltage switchgear.
Performance indicators and parameters
|
Technical Specifications |
indicator |
||
|
Reference standards |
Basic electricity consumption |
GB/T 22264-2008 |
|
|
active energy |
GB/T 22264-2008 |
||
|
Reactive energy |
GB/T 22264-2008 |
||
|
accuracy class |
Reactive energy1.0Other0.5 |
||
|
input |
Applicable network |
Three phase three wire, three phase four wire |
|
|
voltage |
rated value |
AC 100VThe220VThe380V(Please specify when placing an order) |
|
|
overload |
1.2Double continuous,2times/10second |
||
|
power |
<1VA(each phase) |
||
|
impedance |
≥300KΩ |
||
|
current |
rated value |
AC 1AThe5A(Please specify when placing an order) |
|
|
overload |
1.2Double continuous,2times/10second |
||
|
power |
<0.4VA/phase |
||
|
impedance |
<2mΩ |
||
|
frequency |
45-65Hz |
||
|
output |
electrical pulse |
Passive optocoupler collector output |
|
|
Digital communication interface |
RS485/Modbus-RTBaud rate4800/9600(default), no checksum |
||
|
Discrete input |
Active dry contact input |
||
|
discrete output |
Overload alarm or remote control relay output capacityAC5A/250V,DC5A/30V |
||
|
Analog output |
1to3Analog transmission output,4-20mA/0-20mA/0-5V |
||
|
power supply |
voltage range |
AC/DC:85V~264V |
|
|
power |
<5VA |
||
|
insulation resistance |
≥100MΩ |
||
|
power frequency withstand voltage |
input power>2KVInput and output>1KVPower supply and output>2KV |
||
|
Panel protection level |
IP52 |
||
|
Mean time between failuresMTBF |
≥50000h |
||
|
electromagnetic compatible |
Electrostatic discharge immunity test |
GB/T 17626.2-1998(IEC61000-4-2)4level |
|
|
Electrical Fast Transient Pulse Swarm Immunity Test |
GB/T 17626.4-1998(IEC61000-4-4)3Level test voltage: voltage and current1KVPower supply:2KV |
||
|
Surge (impact) immunity test |
GB/T 17626.5-1998(IEC61000-4-5)4level |
||
|
environment condition |
temperature |
work-10℃~55℃Storage:-20℃~70℃ |
|
|
humidity |
≤90%RHNon condensing, non corrosive gas environment |
||
|
altitude |
≤2500m |
||
Product model and function:
Selection Guide:
|
function model |
measurement parameters |
display |
Module functions (options, to be specified when ordering) |
Main dimensions |
|||
|
communication |
pulse output |
transmitter output |
switch module |
||||
|
XZTD-120L/ XZTD-120S |
All electrical parameters in the power network |
LCD/LEDDisplay all parameters |
RS485/MODBUS |
Route Two |
4road |
1-4Road entry or1-2Road out |
Face frame: 120×120 opening 108×108 |
|
XZTD-96L/ XZTD-96S |
All electrical parameters in the power network |
LCD/LEDDisplay all parameters |
RS485/MODBUS |
Route Two |
4road |
1-4Road entry or1-2Road out |
Face frame: 96×96 opening 88×88 |
|
Xzte- 120 L / Xzte-120 s |
All electrical parameters in the power network |
LCD/LEDDisplay all parameters |
RS485/MODBUS |
Route Two |
Not selectable |
Not selectable |
Face frame: 120×120 opening 108×108 |
|
Xzte- 96 L / Xzte-96 s |
All electrical parameters in the power network |
LCD/LEDDisplay all parameters |
RS485/MODBUS |
Route Two |
Not selectable |
Not selectable |
Face frame: 96×96 opening 88×88 |
|
XZTZ-120L
|
Total harmonic content of voltage and current2-31Subharmonic component |
LCDDisplay all parameters |
RS485/MODBUS |
Route Two |
Not selectable |
Not selectable |
Face frame: 120×120 opening 108×108 |
|
XZTZ-96L |
Total harmonic content of voltage and current2-31Subharmonic component |
LCDDisplay all parameters |
RS485/MODBUS |
Route Two |
Not selectable |
Not selectable |
Face frame: 96×96 opening 88×88 |
|
XZTX-120L
|
each15Record active, reactive, and apparent demand once per minute |
LCDDisplay all parameters |
RS485/MODBUS |
Route Two |
Not selectable |
Not selectable |
Face frame: 120×120 opening 108×108 |
|
Model No.: XZTX-96L |
each15Record active, reactive, and apparent demand once per minute |
LCDDisplay all parameters |
RS485/MODBUS |
Route Two |
Not selectable |
Not selectable |
Face frame: 96×96 opening 88×88 |
|
XZTM-120L |
Voltage and current maximum, voltage minimum, active and reactive maximum, power minimum, with64Retrieve event records |
LCDDisplay all parameters |
RS485/MODBUS |
Route Two |
four-way |
Not selectable |
Face frame: 120×120 opening 108×108 |
|
XZTM-96L |
Voltage and current maximum, voltage minimum, active and reactive maximum, power minimum, with64Retrieve event records |
LCDDisplay all parameters |
RS485/MODBUS |
Route Two |
four-way |
Not selectable |
Face frame: 96×96 opening 88×88 |
|
XZTF-120L |
Time division metering of peak, valley, and average total active energy |
LCDDisplay all parameters |
RS485/MODBUS |
Route Two |
Not selectable |
Not selectable |
Face frame: 120×120 opening 108×108 |
|
XZTF-96L |
Time division metering of peak, valley, and average total active energy |
LCDDisplay all parameters |
RS485/MODBUS |
Route Two |
Not selectable |
Not selectable |
Face frame: 96×96 opening 88×88 |
Product Features:
1Can be directly connected to signals from current and voltage transformers, and can be set arbitrarilyPT/CTChange ratio.
2TheLEDOr blue screen backlightLCDScrollable display settings with high visibility.
3,I/OSwitching quantity, relay alarm output,DC4-20mAModular design of analog and other functions.
4Communication access availableSCADA\\PLCIn the system; Can communicate with various communication software in the industry.
5Can carry extreme value measurement, demand measurement64Functions such as event recording.