XPD601 Three phase Multi functional Power Meter Series

NegotiableUpdate on 05/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Electric energy meter series, digital display instrument series Power Automation Series Rail type Power Instrument Series
Product Details



Specification ModelXPD601L-3N
summary:

XPD601L-3N three-phaseNetwork (multifunctional) power meter,It is designed for the power monitoring needs of power systems, industrial and mining enterprises, public facilities, and intelligent buildings. It integrates programmable power measurement, digital communication, and multiple input and output functions, and can measure various commonly used power parameters, such as three-phase voltage, current, active power, reactive power, active energy, reactive energy, harmonics, extreme values, demand, complex rates, etc. It also has multiple expansion modules: digital communication module, digital switch module, power pulse module, analog transmission output module, harmonic measurement module, which can be flexibly selected according to needs. All data can be accessed throughRS485Communication orMODBUSCommunication protocol reading, switch input can be used to monitor the status of switches; The output of the switch quantity can be remotely controlled and triggered with an over limit alarm; The analog transmission output function can replace traditional transmitters.XZThe series of network (multifunctional) power instruments can adapt to all voltage levels and wiring methods, and meet the distribution and centralized control methods of various specifications of high and low voltage switchgear.

Performance indicators and parameters

Technical Specifications

indicator

Reference standards

Basic electricity consumption

GB/T 22264-2008

active energy

GB/T 22264-2008

Reactive energy

GB/T 22264-2008

accuracy class

Reactive energy1.0Other0.5

input

Applicable network

Three phase three wire, three phase four wire

voltage

rated value

AC 100VThe220VThe380V(Please specify when placing an order)

overload

1.2Double continuous,2times/10second

power

1VA(each phase)

impedance

≥300KΩ

current

rated value

AC 1AThe5A(Please specify when placing an order)

overload

1.2Double continuous,2times/10second

power

0.4VA/phase

impedance

2mΩ

frequency

45-65Hz

output

electrical pulse

Passive optocoupler collector output

Digital communication interface

RS485/Modbus-RTBaud rate4800/9600(default), no checksum

Discrete input

Active dry contact input

discrete output

Overload alarm or remote control relay output capacityAC5A/250V,DC5A/30V

Analog output

1to3Analog transmission output,4-20mA/0-20mA/0-5V

power supply

voltage range

AC/DC:85V264V

power

5VA

insulation resistance

≥100MΩ

power frequency withstand voltage

input power>2KVInput and output>1KVPower supply and output>2KV

Panel protection level

IP52

Mean time between failuresMTBF

≥50000h

electromagnetic

compatible

Electrostatic discharge immunity test

GB/T 17626.2-1998IEC61000-4-24level

Electrical Fast Transient Pulse Swarm Immunity Test

GB/T 17626.4-1998IEC61000-4-43Level test voltage: voltage and current1KVPower supply:2KV

Surge (impact) immunity test

GB/T 17626.5-1998IEC61000-4-54level

environment

condition

temperature

work-1055Storage:-2070

humidity

≤90%RHNon condensing, non corrosive gas environment

altitude

≤2500m

Product model and function:

Selection Guide:

function

model

measurement parameters

display

Module functions (options, to be specified when ordering)

Main dimensions

communication

pulse output

transmitter output

switch module

XZTD-120L/

XZTD-120S

All electrical parameters in the power network

LCD/LEDDisplay all parameters

RS485/MODBUS

Route Two

4road

1-4Road entry or1-2Road out

Face frame:

120×120

opening

108×108

XZTD-96L/

XZTD-96S

All electrical parameters in the power network

LCD/LEDDisplay all parameters

RS485/MODBUS

Route Two

4road

1-4Road entry or1-2Road out

Face frame:

96×96

opening

88×88

Xzte- 120 L /

Xzte-120 s

All electrical parameters in the power network

LCD/LEDDisplay all parameters

RS485/MODBUS

Route Two

Not selectable

Not selectable

Face frame:

120×120

opening

108×108

Xzte- 96 L /

Xzte-96 s

All electrical parameters in the power network

LCD/LEDDisplay all parameters

RS485/MODBUS

Route Two

Not selectable

Not selectable

Face frame:

96×96

opening

88×88

XZTZ-120L

Total harmonic content of voltage and current2-31Subharmonic component

LCDDisplay all parameters

RS485/MODBUS

Route Two

Not selectable

Not selectable

Face frame:

120×120

opening

108×108

XZTZ-96L

Total harmonic content of voltage and current2-31Subharmonic component

LCDDisplay all parameters

RS485/MODBUS

Route Two

Not selectable

Not selectable

Face frame:

96×96

opening

88×88

XZTX-120L

each15Record active, reactive, and apparent demand once per minute

LCDDisplay all parameters

RS485/MODBUS

Route Two

Not selectable

Not selectable

Face frame:

120×120

opening

108×108

Model No.: XZTX-96L

each15Record active, reactive, and apparent demand once per minute

LCDDisplay all parameters

RS485/MODBUS

Route Two

Not selectable

Not selectable

Face frame:

96×96

opening

88×88

XZTM-120L

Voltage and current maximum, voltage minimum, active and reactive maximum, power minimum, with64Retrieve event records

LCDDisplay all parameters

RS485/MODBUS

Route Two

four-way

Not selectable

Face frame:

120×120

opening

108×108

XZTM-96L

Voltage and current maximum, voltage minimum, active and reactive maximum, power minimum, with64Retrieve event records

LCDDisplay all parameters

RS485/MODBUS

Route Two

four-way

Not selectable

Face frame:

96×96

opening

88×88

XZTF-120L

Time division metering of peak, valley, and average total active energy

LCDDisplay all parameters

RS485/MODBUS

Route Two

Not selectable

Not selectable

Face frame:

120×120

opening

108×108

XZTF-96L

Time division metering of peak, valley, and average total active energy

LCDDisplay all parameters

RS485/MODBUS

Route Two

Not selectable

Not selectable

Face frame:

96×96

opening

88×88

Product Features:

1Can be directly connected to signals from current and voltage transformers, and can be set arbitrarilyPT/CTChange ratio.

2TheLEDOr blue screen backlightLCDScrollable display settings with high visibility.

3I/OSwitching quantity, relay alarm output,DC4-20mAModular design of analog and other functions.

4Communication access availableSCADA\\PLCIn the system; Can communicate with various communication software in the industry.

5Can carry extreme value measurement, demand measurement64Functions such as event recording.