YSI 58 laboratory dissolved oxygen measuring instrument from Visay/YSI laboratory in the United States

NegotiableUpdate on 04/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The American Visay/YSI laboratory dissolved oxygen measuring instrument is suitable for laboratory and field use, with a wide measurement range and automatic temperature compensation. Clear display of readings. Design practical, expressive, and suitable for laboratory and field use. It can measure concentration in milligrams per liter and air saturation with an accuracy of up to 0.03 milligrams per liter or 0.3% air saturation. The air saturation mode makes the calibration process fast and simple, eliminating the need to measure probe temperature and atmospheric pressure, making it feasible to measure liquids with unknown oxygen solubility coefficients.

Product Details

brand YSI/USA detection limit 0 to 40ppt ± ppm
repeatability Reading after 0.3% compensation ± 1 digit Measurement range 0 to 20 mg/L mg/L
accuracy ±0.3℃mg Measurement principle other
Price range discuss personally Origin category Import
Instrument type Laboratory type

YSI Laboratory Dissolved Oxygen Measurement Instrument in the United StatesSuitable for laboratory and field use, with a wide measurement range and automatic temperature compensation.YSI Laboratory Dissolved Oxygen Measurement Instrument in the United StatesIt has backlight function and can display readings clearly.

Main features of the product:

Design practical, expressive, suitable for laboratory and field use

Measurable milligrams/Enhance concentration and air saturation with high accuracy±0.03mg/Rising or±0.3%air saturation

The air saturation mode makes the calibration process fast and simple, eliminating the need to measure probe temperature and atmospheric pressure, making it feasible to measure liquids with unknown oxygen solubility coefficients

Wide measurement range,0to20mg/Rising or0to200%Air saturation, particularly suitable for measuring supersaturated water samples

Automatic temperature compensation eliminates the effects of membrane permeability coefficient and oxygen solubility caused by changes in water temperature

Direct dial salinity input, compensation range0to40ppt, including accurate temperature compensation, can directly read the dissolved oxygen concentration in the ocean or estuary

LCD screen with background lighting function, can still read clearly in dim environments

The body shell is sealed and waterproof, and comes with a cover for recording output and power interface

Operated using batteries or AC power, with a battery life of1,000Hour (carbon zinc battery), with low battery display

Additional battery packs can be placed inside the body for use with outdoor mixers

Equipped with a recorder output interface, used to connect icon recorders or other recording equipment

YSI Laboratory Dissolved Oxygen Measurement Instrument in the United StatesMain technical parameters:

YSI 58 System Specifications

dissolved oxygen

(% air saturation)

measuring range

Resolution

Accuracy

0 to 200% air saturation

0.1% air saturation

± 0.3% air saturation

Dissolved oxygen

(milligrams per liter)

measuring range

Resolution

Accuracy

0 to 20 milligrams per liter

0.01 milligrams per liter

± 0.03 milligrams per liter

Temperature test

Measurement range

Resolution

Accuracy

-5 to+45 ℃

0. 1℃

±0.3℃

temperature compensation

Measurement range

Accuracy

0 to+45 ℃

5 to+45 ℃: ± 1% milligrams per liter reading; ± 1% air saturation reading

0 to+5 ℃: ± 2% milligrams per liter reading; ± 1.5% air saturation reading

Salinity compensation

measuring range

Accuracy

0 to 40ppt ±

Reading after 0.3% compensation ± 1 digit

operate temperature

measuring range

0 to+45 ℃

Recorder output

voltage

Accuracy

Low load

Full range 0 to 1 volt (0.5 volt=1 digit)

The number to the right of ± 0.4% and ± 1 of the full range (0.01 mg/L mode)

50 kiloohms (output impedance)

power supply

instrument

Blender

4 No. 1 batteries, battery life: 1000 hours (carbon zinc battery)

AC adaptor

Low battery display

Battery level check selection button

size

21.6 cm (length) x 28.0 cm (width) x 9.5 cm (thickness)

weight

1.90 kilograms