According to the search results, the common faults and solutions of LPG centrifugal spray dryer are as follows:
1、 Wall sticking problem of drying tower
1. Fault phenomenon:
The material clumps or forms water droplets on the tower wall, causing the product to be unable to be discharged normally.
The main reasons include: excessive feed volume, high hot air temperature (exceeding the melting point of the material), improper selection of atomizer, uneven distribution of hot air or insufficient circulating air volume.
2. Solution:
Adjust the feed pump speed to reduce the sample loading volume;
Reduce the temperature of the hot air to below the melting point of the material to avoid melting and adhesion;
Optimize the angle of the hot air distributor to ensure even distribution of hot air;
Add air sweeping devices, air hammers, or rotating scrapers to automatically shake off wall sticking materials;
Clean the air inlet filter and increase the circulating air volume.
2、 Nebulizer malfunction
1. Fault phenomenon:
The atomizer does not produce fog, has a small amount of fog, or frequently breaks the fuse.
The reasons include: chip aging and scaling, damage to circuit components (such as transistors and relays), abnormal base voltage, or changes in oscillation frequency.
2. Solution:
Replace the aging atomizer chip;
Check and repair circuit components (such as transistors and relays) to ensure parameter matching;
Adjust the base bias circuit (such as W1 and W2 potentiometers);
Regularly clean the chip to prevent scaling from affecting atomization efficiency.
3、 Abnormal temperature control
1. Fault phenomenon:
The intake/exhaust temperature is unstable or deviates from the set value (such as high exhaust temperature).
Reasons include: abnormal refrigerant dosage, condenser blockage, sensor malfunction or insufficient heat source output.
2. Solution:
• Supplement or adjust the refrigerant quantity to the standard range;
Clean the condenser and filter to ensure smooth heat dissipation;
Replace the faulty temperature sensor or controller;
Check the heat source system (such as steam pressure, electrical compensation device) to ensure stable heating.
4、 Material receiving system failure
1. Fault phenomenon:
The cyclone separator has low material collection efficiency or material residue.
The reasons include: blockage of the cyclone separator, malfunction of the shut-off fan, and poor sealing of the pipeline.
2. Solution:
Clean the cyclone separator and collection bin to avoid material accumulation;
• Check or replace the shut-off fan to ensure continuous discharge;
Check the airtightness of pipeline connections to prevent dust from escaping due to air leakage.
5、 Electrical and control system malfunction
1. Fault phenomenon:
The compressor does not start, the overload protection frequently operates, or the control fails.
The reasons include: abnormal power supply voltage, damaged capacitors, virtual connections in the circuit, or controller program errors.
2. Solution:
Check the stability of the power supply and the firmness of the wiring;
Replace burnt capacitors or relays;
Reset or replace the faulty controller and recalibrate the parameters.
6、 Abnormal vibration and mechanical failure
1. Fault phenomenon:
Excessive vibration or abnormal bearing noise during equipment operation.
Reasons include: rotor imbalance, bearing wear, or coupling failure.
2. Solution:
Clean or rebalance the rotor;
Replace damaged bearings and adjust clearances;
Tighten the coupling bolts and adjust the alignment.