1、 Daily cleaning and basic maintenance
1. Equipment cleaning
After each use, it is necessary to immediately clean the crushing chamber, blades, and residual materials at the inlet and outlet to avoid oxidation or bacterial growth of residual hyaluronic acid, which may affect the subsequent use effect. Use a soft cloth and neutral cleaning agent to wipe during cleaning, and do not use corrosive chemicals.
The external surface should be kept dry to prevent moisture from penetrating and causing circuit short circuits or metal parts to rust.
2. Lubrication and fastening inspection
Regularly add specialized lubricating oil to key moving parts such as spindle bearings and gears to reduce wear and reduce operating noise.
Check whether the connecting components of the equipment (such as screws and pipe interfaces) are loose and tighten them in a timely manner to prevent safety hazards caused by vibration.
2、 Core component maintenance
1. Replacement of vulnerable parts
Fragile parts such as blades and screens need to be regularly inspected for wear. If the blade gap exceeds 1mm or the screen is deformed, it should be replaced immediately to avoid affecting the fineness and efficiency of crushing.
When replacing the blade, it is necessary to ensure weight balance (error ≤ 1g) to avoid abnormal vibration of the equipment caused by imbalance.
2. Electrical and cooling system
Regularly check the operation status of the motor, monitor the stability of voltage and current, and prevent equipment damage caused by overload heating.
Clean the radiator and coolant channels to ensure efficient operation of the cooling system and prevent degradation of hyaluronic acid active ingredients due to high temperatures.
3、 Deep maintenance and operational standards
1. Regular special inspections
Conduct quarterly inspections of equipment sealing and dust removal systems (such as bag filters) to prevent leaks or blockages that may affect crushing efficiency and environmental hygiene.
Check the integrity of the insulation layer of the electrical circuit, replace aging cables, and avoid the risk of short circuits.
2. Key points for safe operation
Confirm that the parameter settings (such as speed and temperature) are reasonable before operation to avoid overloading that may cause equipment overheating or component breakage.
Wear protective equipment such as goggles and gloves during operation to prevent material splashing or mechanical injury.
4、 Long term storage recommendations
1. When the equipment is idle, it should be thoroughly cleaned and coated with anti rust oil, and stored in a dry and ventilated environment to avoid moisture corrosion of metal parts.
2. Regularly power on and idle (once a month) to maintain the activity of the motor and transmission system and prevent lubricant solidification caused by prolonged standing.