Stainless steel plate and frame filter press is a device used for liquid-solid separation, widely used in industries such as chemical, food manufacturing, and pharmaceuticals. This article will introduce the operating procedures of stainless steel plate and frame filter press to ensure its normal operation.
1、 Equipment installation
Before installation, carefully read the instructions and check for any damage to the equipment. If there is any damage, contact the manufacturer promptly for replacement or repair. During installation, the appropriate installation position should be selected based on the equipment model and ground conditions to avoid oil leakage or machine tilting. During the installation process, attention should also be paid to anti slip, shock resistance, and securing equipment.
2、 Preparation before operation
Before use, the external pipeline should be connected to the equipment pipeline and checked to ensure that the joint is firm and free of air and liquid leakage. Refuel the machine and check if the oil level is within the specified range. Start the equipment under normal temperature and continuously observe its operation.
3、 Operation process
1. Before starting operation, check whether the connections and seals of each part of the equipment are in good condition.
2. In addition, the pressure gauge should be checked to maintain good oil circuit condition.
3. After starting the equipment, attention should be paid to observing the thickness of the filter cake and the flow rate of the filtrate. After reaching a certain level, the treatment should be stopped.
4. After processing, pay attention to cleaning the equipment and discharging the waste liquid. The cleaning method can be processed according to different materials.
5. Regularly clean visible dirt to ensure the cleanliness of the equipment and extend its service life. Meanwhile, attention should also be paid to the protection against dust and pollutants.
4、 Stop the device
At this point, safety factors and evacuation treatment need to be considered. The operation switch, unloading valve, and drain valve of the equipment should be closed first, and then the liquid inside the equipment should be drained. If no further treatment is needed at this time, it is necessary to promptly remove the filter cloth or clean the accumulated dirt on the filter plate.