SJ-SGP is based on the principle that any substance has an absorption effect on specific wavelengths of light, and accurately measures the content of the substance dissolved in water by measuring the degree of absorption of these substances on specific wavelengths of light. The online full spectrum multi parameter sensor uses a xenon lamp as the light source, which can emit light of all wavelengths from near ultraviolet to near infrared. The full range of spectral information is collected through a micro fiber spectrometer. In addition, specific algorithms are used to compensate for the attenuation of the optical path and to some extent eliminate the interference of particulate suspended matter impurities, thereby achieving more stable and reliable measurements.
Product Features:
No need for reagents, no pollution, economical and environmentally friendly
More convenient installation, allowing for uninterrupted online water quality monitoring
Can measure COD, BOD, TOC, chromaticity, turbidity TP、TN、NHN、 Parameters such as nitrate and nitrite
Automatically compensate for turbidity interference
Small drift, fast response, and more accurate measurement
Even with long-term monitoring, it still has strong stability
Maintenance free, long service life, low usage cost
Digital sensor, RS-485 interface, Modbus/RTU protocol
Low power design, anti-interference design
Technical Specifications
| Measuring principle |
Full spectrum absorption method |
| measurement range |
COD |
chroma |
TOC |
turbidity |
BOD |
| 0~200mg/L equiv. KHP |
0~500Hazen |
0~150mg/L |
0~400NTU |
0~150mg/L |
| measurement range |
TP |
TN |
NHN |
nitrate |
nitrite |
| 0~15mg/L |
0~100mg/L |
0~80mg/L |
0~15mg/L |
0~10mg/L |
| COD精度 |
±5%F.S. |
| COD resolution |
0.1mg/L |
| Chromaticity accuracy |
±5%F.S. |
| Chromaticity resolution |
0.1 Hazen |
| TOC accuracy |
±5%F.S. |
| TOC resolution |
0.1mg/L |
| Turbidity accuracy |
±5%F.S. |
| Turbidity resolution |
0.1NTU |
| BOD accuracy |
±5%F.S. |
| BOD resolution |
0.1mg/L |
| TP accuracy |
±5%F.S. |
| TP resolution |
0.1mg/L |
| TN accuracy |
±5%F.S. |
| TN resolution |
0.1mg/L |
| NHN accuracy |
±5%F.S. |
| NHN resolution |
0.1mg/L |
| Nitrate accuracy |
±5%F.S. |
| Nitrate resolution |
0.01mg/L |
| Nitrite accuracy |
±5%F.S. |
| Nitrite Resolution |
0.01mg/L |
| calibration method |
Spectral calibration |
| output method |
RS-485(Modbus/RTU) |
| power supply |
12~24VDC |
| power consumption |
0.2W@12V |
| working conditions |
0~45℃、<0.1MPa |
| Storage temperature |
-5~65℃ |
| Protection level |
IP68 |
| Installation method |
Immersion installation |
| Cable length |
5 meters, other lengths can be customized |
| Sensor housing material |
316L stainless steel |
Size chart

Note: The sensor connector is a male M16-5 core waterproof connector