Brief Introduction

1、 Product Introduction

An online multi parameter water quality detector is an instrument that can simultaneously measure multiple water quality parameters. It integrates multiple sensors and measurement modules for communication and storage, which can quickly and accurately record multiple key parameters in the water body. Including but not limited to pH value, dissolved oxygen (DO), conductivity, turbidity, temperature, ammonia nitrogen, etc., they can be combined and configured according to different needs and applications. Historical monitoring data and alarm history records can be recorded and stored, and historical data export is supported. xlsx. The RS485 interface supports the MODBUS-RTU communication protocol, allowing users to freely communicate and connect with devices such as PLC, DCS, configuration software, DTU, etc. to transmit data.

2、 Application fields of multi parameter water quality monitoring instrument

Online multi parameter water quality detectors are widely used for monitoring and controlling various water bodies, including but not limited to the following fields:

1. Water treatment plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water, ensuring the safety and hygiene of tap water.

2. Groundwater monitoring: used to monitor parameters such as pH value, conductivity, temperature, etc. of groundwater, in order to timely detect and solve water quality problems.

3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, in order to take timely pollution control measures.

4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, in order to timely detect and control marine pollution.

5. Sewage treatment: used to monitor the water quality parameters of sewage, such as pH value COD、 Ammonia nitrogen and other substances are used to control and regulate the sewage treatment process.

6. Industrial production: used to monitor the water quality status in the industrial production process, such as pH, conductivity, dissolved oxygen and other parameters, in order to adjust the process in a timely manner and ensure product quality.

7. Scientific research: used for water quality monitoring in the field of scientific research, such as eutrophication of lakes, climate change, and other studies.

3、 Technical characteristics of multi parameter water quality monitoring instrument

1. High reliability: suitable for long-term work in outdoor environments, with stable measurement and strong anti-interference ability.

2. Flexible and portable: Each probe can be freely combined and replaced independently, plug and play.

3. Scalability: Multiple sensors can be freely combined.

4. Multiple applications: rapid on-site measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water sources, and urban pipeline water.

5. Resilient shell: ABS+PC material, corrosion-resistant, capable of long-term continuous normal operation.

6. Compact structure: can be installed in smaller sizes.

7. Communication connection: RS485 expansion interface, isolated master/slave interface for independent communication.

4、 Technical parameters of multi parameter water quality analyzer

display output 4.3-inch touch screen with strong LED backlight, operable under direct sunlight
power supply DC power supply: DC12V
power consumption The power consumption of the instrument is about 12V/1W
Sound output buzzer
communication protocol Standard RS485 Modbus RTU protocol and device master/slave transmission channel support
Main materials ABS+PC material
Storage temperature -20 to 70 ℃
Operating temperature -10 to 50 ℃
Protection level IP65
size 175mm * 140mm * 49mm (length x width x height)
weight About 0.5KG

5、 Product size

Size charte4b56ff3ecceaae880abb04af09d154e_ecdcd8a238bda5a223a9574f200f9d49.png


6、 Sensor configuration (optional)


PH
Measurement principle: electrochemistry (salt bridge)
Signal mode: RS485 (MODBUS-RTU)
Measurement range: 0~14 (PH)
Resolution: 0.01
Measurement accuracy: ± 0.1PH ± 0.1 ℃
Cable length: 5 meters as standard
Measurement environment: temperature 0~50 ℃ (non freezing),<0.2Mpa
Waterproof rating: IP68
Installation method: Immersion installation, NPT3/4 thread

ORP
Measurement principle: electrochemistry (salt bridge)
Signal mode: RS485 (MODBUS-RTU)
Measurement range: -1500~+1500 (mV)
Resolution: 1mV
Measurement accuracy: ± 6 mV
Cable length: 5 meters as standard
Measurement environment: temperature 0~50 ℃ (non freezing),<0.2Mpa
Waterproof rating: IP68
Installation method: Immersion installation, NPT3/4 thread

COD
Measurement principle: UV 254 absorption method dual light source measurement
Signal mode: RS485 (MODBUS-RTU)
Measurement range: 0~200mg/L 0~500mg/L
Resolution: 0.1mg/L
Measurement accuracy: ± 5% ± 0.3 ℃
Cable length: 5 meters as standard
Measurement environment: temperature 0~50 ℃ (non freezing),<0.2Mpa
Waterproof rating: IP68
Installation method: Immersion installation, NPT3/4 thread self-cleaning function: equipped with an automatic cleaner to prevent biological attachment, avoid light window pollution, and ensure long-term monitoring stability; Automatic cleaning time and frequency can be set, with a power consumption of 0.7W

Conductivity EC
Measurement principle: Contact electrode method
Signal mode: RS485 (MODBUS-RTU)
Measurement range: 0~5000 us/cm
Resolution: 1 US/cm
Measurement accuracy: ± 1.5% ± 0.1 ℃
Cable length: 5 meters as standard
Measurement environment: temperature 0~50 ℃ (non freezing),<0.2Mpa
Waterproof rating: IP68
Installation method: Immersion installation, NPT3/4 thread

Dissolved oxygen (DO)
Measurement principle: Fluorescence lifetime method
Signal mode: RS485 (MODBUS-RTU)
Measurement range: 0-20mg/L
Resolution: 0.01mg/L
Measurement accuracy: ± 2% ± 0.3 ℃
Cable length: 5 meters as standard
Measurement environment: temperature 0~50 ℃ (non freezing),<0.2Mpa
Waterproof rating: IP68
Installation method: Immersion installation, NPT3/4 thread

Suspended solids SS
Measurement principle: scattered light method
Signal mode: RS485 (MODBUS-RTU)
Measurement range: 0~2000mg/L
Resolution: 0.1mg/L
Measurement accuracy: ± 5% (depending on sludge homogeneity)
Cable length: 5 meters as standard
Measurement environment: temperature 0~50 ℃ (non freezing),<0.2Mpa
Waterproof rating: IP68
Installation method: Immersion installation, NPT3/4 thread

Turbidity TU
Measurement principle: scattered light method
Signal mode: RS485 (MODBUS-RTU)
Measurement range: 0~40NTU 0~1000NTU 0~3000NTU
Resolution: 0.1NTU
Measurement accuracy: ± 1% ± 0.3 ℃
Cable length: 5 meters as standard
Measurement environment: temperature 0~50 ℃ (non freezing),<0.2Mpa
Waterproof rating: IP68
Installation method: Immersion installation, NPT3/4 thread

ammonia nitrogen
Measurement principle: ion selective electrode method
Signal mode: RS485 (MODBUS-RTU)
Measurement range: 0-1000.00mg/L (default)
0-1000mg/l/(customizable)
Resolution: 0.01mg/l
Measurement accuracy: 10% of the reading, ± 0.5 ℃
Cable length: 5 meters as standard
Measurement environment: temperature 0~50 ℃ (non freezing),<0.2Mpa
Waterproof rating: IP68
Installation method: Immersion installation, NPT3/4 thread

chlorophyll
Measurement principle: Fluorescence method
Signal mode: RS485 (MODBUS-RTU)
Measurement range: 0-400ug/L
Resolution: 0.01ug/L
Measurement accuracy: R2>0.999
Cable length: 5 meters as standard
Measurement environment: temperature 0~50 ℃ (non freezing),<0.2Mpa
Waterproof rating: IP68
Installation method: Immersion installation, NPT3/4 thread self-cleaning function: equipped with an automatic cleaner to prevent biological attachment, avoid light window pollution, and ensure long-term monitoring stability; Automatic cleaning time and frequency can be set, with a power consumption of 0.7W