Welcome Customer !

Membership

Help

Wenzhou Qianhao Machinery Technology Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Article

Wenzhou Qianhao Machinery Technology Co., Ltd

  • E-mail

    qhjx998@163.com

  • Phone

    15988724193

  • Address

    1st Floor, 258 Dingxiang Road, Binhai Park, Wenzhou Economic and Technological Development Zone, Zhejiang Province

Contact Now
Instructions for using microporous membrane filters
Date: 2023-07-28Read: 0
1. Installation base: Before installation, check the direction of the inlet and outlet clearly. The liquid should flow from the outside of the filter element to the center, and the pipeline connected to the filter element socket is the outlet. There are arrows indicating the flow direction on the filter pipeline, do not connect them incorrectly.
2. Install filter element: The 222 socket is a plug-in type, and the 226 socket is a snap in type. If it is a multi-core filter, the pressure plate should be placed on the fins and the bolts should be tightened appropriately (the filter element will elongate under high temperature, and if the pressure plate is too tight, the filter element will have no space for elongation, which will cause twisting deformation and affect the filtration accuracy).
3. Install the outer cover and seal it with clamps (single core) or bolts (multi-core) connected to the base. Pay attention to placing the sealing gasket flat and check that there is no leakage at the sealing point.
4. Filter disinfection: New filters must be cleaned thoroughly before use. The filter used for sterilization should be disinfected and sterilized, and the disinfection work should generally be carried out on the production line to avoid external pollution. On site steam disinfection should strictly control the steam pressure and pressure difference to avoid damaging the filter element due to excessive steam pressure and pressure difference.
5. When filtering liquids, the exhaust valve at the top of the filter should be opened first to exhaust the gas inside the cylinder and allow the liquid to fill the cylinder, otherwise it will affect the flow rate.
6. When filtering media through a filter, there will be a pressure drop due to resistance (i.e. the pressure difference between the inlet and outlet). In order to overcome this resistance and maintain sufficient flow, it is necessary to have sufficient working pressure when necessary. We provide corresponding temperature and pressure limit values for each filter element, please use them according to the requirements. To avoid excessive flow impact on the filter element, be sure to open the valve slowly!
7. When using a self selected pump, please pay attention to matching the flow rate and pressure. It is advisable to choose self-priming pumps such as vortex pumps and infusion pumps.
8. When shutting down, the filtered liquid should be drained. If the time is not long, the filter does not need to be opened; If the time is long or the filtrate is not suitable for long-term storage, the filter or filter element should be cleaned.