404The Meineng Pulmonary Function Analyzer is a measuring instrument that can perform lung function tests and track lung health. It can measure commonly used lung function testing parameters including FVC, FEV1, FEV1/FVC, etc. Pulmonary function analyzer with tidal volume loop for FVC and VC measurement, real-time waveform display for MVV measurement, pre - and post medication airway reactivity test, FEV1 drug sensitivity test loop, lung age evaluation, regression analysis chart of FEV1 decline rate.
Pulmonary function testing is a simple examination item that is an objective indicator of airflow limitation and good repeatability. It is of great significance for the diagnosis, severity evaluation, disease progression, prognosis, and treatment response of acute exacerbation of chronic obstructive pulmonary disease.
Please feel free to use the body of the Meineng Pulmonary Function Analyzer, which comes with a handle for easy bedside and outdoor examinations at any time. Fully functional, including ventilation, capacity, as well as bronchial dilation and stimulation experiments, with over 60 parameters to comprehensively evaluate lung function status.
Guidelines for using the Meineng Pulmonary Function Monitor:
1. Before using the instrument, it is necessary to carefully read the user manual in both Chinese and English.
2. Be sure to turn off the power switch before inserting and removing the sensor.
3. Before connecting to an external power source, ensure that the voltage and frequency are consistent with the local device (100-240 volts, 50/60 hertz).
4. The suitable ambient temperature for using this instrument is 10-30 ℃ and the relative humidity is 30-85%.
5. Do not modify the instrument for other purposes without authorization.
6. When in use, the temperature of the hot wire is about 400 ℃, so no water droplets can enter the hot wire to avoid damaging the sensor.
7. Due to the high temperature of the hot wire during use, there should be no flammable or explosive materials present in the testing environment.
8. When conducting lung function tests, please be sure to use a filter chamber containing a clean and dry filter screen together with the sensor to avoid burning the sensor's hot wire; Cleaning and disinfection is to separate the filter chamber on the sensor and clean the filter chamber cover and filter screen with clean water.
If you have equipment requirements or would like to know more details and quotations, please feel free to contact Shanghai Oberson Medical Equipment Co., Ltd. for consultation.