10-200ml min medium high pressure liquid chromatography

NegotiableUpdate on 03/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
10-200ml min medium high pressure liquid chromatography
Product Details

PC-10-200 series medium high pressure liquid chromatography chromatography system (Application level: small experimental type, semi preparation type, small preparation type)

System Characteristics

Modular design

Convenient for users to choose and match the required equipment, and with a small footprint. Gradient configuration; It can run precise binary gradients and can also be equally configured. All valve and other pipeline joints are located on the right side, and a reasonable pipeline layout greatly reduces dead volume in the pipeline. Connecting the instrument backend to a fixed column can form a whole, making it convenient for users to choose and match.

infusion system

Dual plunger parallel mode, series mode, floating plunger design, online real-time cleaning function, maintenance free.

system detection

The online 190nm-700nm UV detector (or other online detectors) uses imported deuterium and tungsten lamp light sources, ensuring reliable quality.

Component collection

Robot arm mode, high-precision positioning, powerful automatic collection capability, supports full collection, and peak collection (threshold, slope).

software

The automatic buffer preparation function facilitates quick exploration of purification processes, and the corresponding parameters are programmed according to on-site process requirements. Real time monitoring and control of flow paths; The same screen displays UV, gradient spectral lines, and collection tube numbers. Automatic software control improves the purity and repeatability of collection, enabling the system to obtain more separation information of samples and impurities in a timely manner, making the tedious chromatographic purification process easy and convenient.

technical specifications

Light source s Imported deuterium lamps and tungsten lamps
wavelength range 190nm-700nm continuous online wavelength setting, no need to change the lamp, can detect 2 wavelengths simultaneously.
Wavelength online scanning Full range scanning from 190nm to 700nm
Wavelength accuracy ±1nm
Wavelength reproducibility: 0.2nm、
baseline noise 0-5AU ±0.5×10-5AU
Range of absorbance -5AU--5AULinear: ± 2%, between 0-2 AU
pump head Material: Stainless steel pump head (ceramic and PEEK optional), imported ruby ball one-way valve, high precision, long service life.
flow rate range 0.01-99.99ml/min, 0.1-50ml/min, 0.1-100ml/min, 200ml/min (flow rate can be customized)
Flow velocity accuracy ±1%
Traffic reproducibility ±1%
Maximum pressure 35MP、25MP、20MP、15MP
gradient type Linear, isomorphic, and adjustable gradient online
Static Mixer Online solution mixing, using countless ceramic microspheres to ensure uniformity during gradient mixing, with the function of online filtration to protect the chromatography column. The mixer has 4 tubes, with one tube being 2ml and two tubes being 4m
Gradient mixing accuracy: ± 0.5%, gradient mixing accuracy: 0.3% RSD does not vary with backpressure
Maximum dead volume: 8ml
Sample size and mode Set the sample size according to the user's process requirements, (Sample can be loaded onto a quantitative tube, 200ul-5ml, or add a conversion valve to the sample pump)
Component collection
perhaps
Valve channel collection
Robot arm mode: high-precision positioning
Peak Collection: Automatically collect based on volume, time, threshold, and slope.
Collection modes: Normal mode, sequential collection, and cyclic collection, making collection more intelligent and user-friendly
Adopting imported high-precision three-way valves while utilizing bottle cutting technology, the waste liquid has an independent channel, and there is no dripping or leakage during the bottle switching process
The supporting software can collect multiple wavelength signals in real time, and the collected signals can be selected arbitrarily
Capacity: 120 test tubes (height 90-180mm, height x 13-15mm diameter);
80 test tubes (height 90-180mm, height x 18mm diameter);
Valve collection: 7 channels for collecting samples and 1 channel for discharging waste liquid. power supply
220VAC/110VAC Power frequency
50Hz operation temperature
1-40℃ Control Interface
RS-232C(USB), Using a PC based on Windows XP or Windows 7

The software control platform can display UV and gradient spectra, as well as display the collected test tube numbers.