PAS-A series low-pressure liquid chromatography separation and chromatography system
Low pressure liquid chromatography separation chromatography system is used for scientific research and preparation in industries such as biochemistry, synthetic chemistry, natural products, drug development, food chemistry, agricultural chemistry, cosmetics, polymers and petrochemicals.
The technical specifications of the UV detector in the system configuration are required for quantitative testing of drugs in pharmaceutical factories across the country.
| product name |
Configure instruments |
Specification |
| Low pressure liquid chromatography analysis system |
1. HDL-A Combined UV Detector (including computer constant current pump) 2. BSZ-100 Partial Collector 3. Ordinary chromatography column 4. Solvent box |
1. Test wavelength: 254nm, 280nm-400nm optional (display absorbance value) USB interface, 6 analysis methods for data analysis and calculation Flow rate: 0.6-200ml/min, pressure:>3.5Kg, digital display speed 2. Timing range: 1-9999.99 seconds, collection range: 12mlx100 seconds 3. Chromatography column: φ 10 × 200; φ16×500; φ26×600(mm) 4. One drawer and two open shelves for storing buffer bottles |
| 1. HDL-A Combined UV Detector (including computer constant current pump) 2. BSZ-100 Partial Collector 3. Ordinary chromatography column 4. Solvent box 5. Six way injection valve 6. TH-500 gradient mixer Composition:(Simple gradient chromatography purification and separation device) |
1. Test wavelength: 254nm, 280nm-400nm optional (display absorbance value) USB interface, 6 analysis methods for data analysis and calculation Flow rate: 0.6-200ml/min, pressure:>3.5Kg, digital display speed 2. Timing range: 1-9999.99 seconds, collection range: 12mlx100 seconds 3. Chromatography column: φ 10 × 200; φ16×500; φ26×600(mm) 4. One drawer and two open shelves for storing buffer bottles 5. Pressure: 20kg/cm, solvent contact: PTFE, 316 stainless steel 6. Not resistant to organic matter, provides gradient: 1000ml, gradient shape: can be straight |
|
|
Note: 1. PC and printer users can customize locally or purchase on their behalf. 2. Standard wavelength: 254nm, 280nm 3. Users can configure different models and specifications of partial collectors, gradient mixers, chromatography columns, etc. according to their needs 4. Users can choose according to their needsSample pool: * optionalFlow Sample Cell: U-shaped(Used for semi preparation)optical path4mm flow rate: 0-200ml/min |
||