strive forAccurate online residual chlorine analyzerFCl-2058 adopts a film covered constant potential method with a 3-electrode system, which hasTechnological advantages and wide industry applications. The electrode has achieved automatic temperature compensation internally, ensuring high accuracy and stability of measurement results. The special membrane structure enables it to resist surfactants, has excellent mechanical strength, and is not easily damaged. In repeated tests at pH 7.2 and 25 ° C, the accuracy is less than 1% within the range of less than 2ppm. The zero point of the electrode is stable and does not drift, with a slope drift of about -1% per month. In addition, the FCl-2058 electrode adopts the standard Modbus RTU (485) communication protocol, DC 24V power supply, and four wire mode, which can be easily connected to the sensor network.
high-precision measurementUnder the conditions of pH=7.2 and 25 ° C, the accuracy is less than 1% within the range of less than 2ppm, ensuring the accuracy of the measurement results.
Automatic temperature compensationThe electrode has achieved automatic temperature compensation internally, effectively eliminating the influence of temperature on measurement results.
Anti surfactantThe special membrane structure enables it to resist surfactants and is suitable for a variety of complex water quality environments.
High mechanical strengthThe electrode membrane structure has excellent mechanical strength, is not easily damaged, and extends its service life.
Zero point stabilityThe zero point of the electrode is stable and does not drift, ensuring long-term reliability.
Low slope driftThe slope drift is about -1% per month, reducing the need for frequent calibration.
Standard Communication ProtocolAdopting the standard Modbus RTU (485) communication protocol, it supports DC 24V power supply and four wire mode, making it easy to integrate into various sensor networks.
efficient monitoringThe FCl-2058 electrode can monitor the residual chlorine content in water in real-time and accurately, providing users with timely data support and ensuring water quality safety.
Reduce maintenance costsThe zero point stability and low slope drift characteristics of the electrode reduce the need for frequent calibration and lower maintenance costs.
wide applicabilitySuitable for various water quality environments such as swimming pool water, drinking water, seawater, etc., to meet the needs of different users.
Easy to integrateThe standard Modbus RTU (485) communication protocol and four wire mode enable easy integration of electrodes into existing sensor networks, improving system flexibility and scalability.
The FCl-2058 electrode is widely used in the following fields:
Pool water treatmentReal time monitoring of residual chlorine content in swimming pool water to ensure water quality safety and prevent bacterial growth.
Drinking water treatmentMonitor the residual chlorine content in drinking water to ensure water supply safety and compliance with hygiene standards.
Seawater treatmentSuitable for residual chlorine monitoring in seawater desalination and seawater treatment processes, ensuring water quality meets standards.
Industrial water treatmentMonitor the residual chlorine content in industrial water to ensure water quality safety during the production process.
sewage treatmentMonitor the residual chlorine content during the sewage treatment process to ensure that the effluent quality meets the discharge standards.
Measuring substancesFree chlorine
Measuring principleFilm covered three electrode current method
Optional range0.005-0.50/2.00ppm or 0.05-5.00/10.00/20.00ppm
PH range:2.0-11
precisionMeasurement range 2 mg/L: within 0.4 mg/L<1%, within 1.6 mg/L<1%; -Measurement range of 20 mg/L: within 4 mg/L<1%, within 16 mg/L<3%
Operating Temperature:0-50°C
Medium flow rate:15-30 L/H
pressure:1.5 bar
zero point calibration: No need
Slope calibrationAccording to chemical analysis methods, calibrate the equipment
driftLess than -1% per month
response timeIt takes 1 minute to reach 90% of the measured value
Polarization time: 2 hours
electrical connection: 4-pole plug, 5-pole M12 connector, 2-terminal
power supply:DC 9-30V
output signalTwo wire system 4-20mA, Modbus 485, 0- ± 2V
sizeDiameter 25mm, length 175-220mm
material: Microporous hydrophilic membrane PVC-U、PEEK、 stainless steel
maintenance intervalMembrane cap: replaced once a year, electrolyte: 3-6 months
storageElectrode rod and membrane cap: 5-40 ° C in a dry environment, electrolyte: 5-35 ° C in a cool and dark place
CE Certification:EMC、RoHS
strive forAccurate online residual chlorine analyzerFCl-2058 has become an ideal choice in the field of water quality monitoring due to its technical performance and wide range of application areas. Whether in pool water, drinking water, seawater, or industrial water treatment, FCl-2058 can provide accurate and reliable residual chlorine monitoring data to ensure water quality safety and enhance user experience. Choose FCl-2058 now to make your water quality monitoring more efficient and reliable!