E-mail
616708668@qq.com
- Phone
-
Address
3rd Floor, Building 17 (Baoxing Injection Molding Factory), Shasan Shangxiawei Industrial Zone, Shajing Street, Bao'an District, Shenzhen City
Shenzhen Junhaotong Technology Co., Ltd
616708668@qq.com
3rd Floor, Building 17 (Baoxing Injection Molding Factory), Shasan Shangxiawei Industrial Zone, Shajing Street, Bao'an District, Shenzhen City
Main parameters:
Product Name |
air conditionersmart socket |
appearance |
Type 86 (with button switch) |
model |
JHT-ZNCZ03-86 |
Maximum current |
16A |
Type of socket |
Three sockets |
rated voltage |
110V~260V |
size |
86mm*86mm*37mm |
rated power |
1100W |
weight |
200g |
Shell material |
Flame retardant PC |
Operating Temperature |
-20℃~+70℃ |
fire rating |
V0 |
Operating Humidity |
5%~85% |
connection method |
2.4G wireless communication/carrier communication |
power consumption |
1.5W |
communication method |
Wireless/Carrier |
Running indicator light |
Normal operation closing: slow flashing blue indicator light2Instantly bright100mSThe blue indicator light is in the closed state2Flash in seconds, light up1One second off, one second off |
Communication indicator light |
none |
Relay lifespan |
Pure resistive 100000 times, capacitive 50000 times |
communication protocol |
DL/T645-2007 |
Main functions:
serial number |
name |
Instructions |
1 |
Electric energy metering function |
It can measure active energy in both forward and reverse directions separately, and can combine active energy according to different user settings. |
2 |
Measurement function |
Capable of measuring parameters such as voltage, current, active power, reactive power, power factor, and grid frequency in circuits. |
3 |
Remote control function |
The socket itself comes with a relay, which can control the power on and off of the socket by sending tripping and closing instructions through the backend server. |
4 |
Press the button to apply for forced closing function |
In special circumstances, when the socket is in the closed state, the relay can be closed by long pressing the button on the socket (long pressing for 5 seconds), and the power on duration can be set (default at the factory is 6 hours). |
5 |
Overload automatic power-off function |
When the load power of the socket exceeds the maximum limit power (adjustable, factory default value is 3.3 kW), and the duration exceeds the maximum power delay judgment time (adjustable, factory default value is 10 seconds), the socket will automatically trip and cut off power. When the trip time reachesOpening time after overload (adjustable, factory default value is)20The socket will automatically close and restore power supply in seconds. |
6 |
Set table bottom function |
To facilitate the replacement of sockets, the power base of the socket can be set. |
7 |
Infrared communication function |
The socket itself comes with an infrared communication interface, with a fixed baud rate of 1200, making it convenient for infrared handheld devices to set its parameters. |
8 |
Automatic networking function |
The 2.4G wireless module of the socket and the host adopts frequency conversion technology (the communication frequency band is calculated by the room number), and the network is automatically converted according to the room number. |
9 |
Support broadcasting to set room numbers |
During installation, simply use the handheld broadcast to set the room number to achieve automatic networking, without the need to set room numbers one by one, making the operation simple and reliable. |