Welcome Customer !

Membership

Help

Sifang Optoelectronics Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Sifang Optoelectronics Co., Ltd

  • E-mail

    marketing@gassensor.com.cn

  • Phone

    13296672587

  • Address

    No. 3 Fenghuangyuan 3rd Road, Fenghuangyuan Industrial Park, Donghu New Technology Development Zone, Wuhan City

Contact Now

Battery thermal runaway monitoring sensor ATRS-1022

NegotiableUpdate on 01/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The ATRS-1022 battery thermal runaway monitoring sensor can effectively monitor indicators such as CO2, H2, and particulate matter concentration released before the battery thermal runaway is triggered, and transmit measurement signals to the BMS through CAN or LIN communication (customizable). It has significant characteristics such as accurate measurement, fast response time, low cross interference, low power consumption, long lifespan, and high reliability.

Product Details

Battery thermal runaway monitoring sensor ATRS-1022It can effectively monitor indicators such as CO2, H2, and particulate matter concentration released before triggering battery thermal runaway, and transmit measurement signals to BMS through CAN or LIN communication (customizable). It has significant characteristics such as accurate measurement, fast response time, low cross interference, low power consumption, long lifespan, and high reliability.

Product Features

  • ultra-low power

  • No gas cross interference, leak prevention and false alarm

  • High precision, fast response time

  • Vehicle grade design, adaptable to harsh onboard environments

Battery thermal runaway monitoring sensor ATRS-1022Technical Specifications

model ATRS-1022
Measuring principle NDIR dual channel+MOX+light scattering
Measure components PM2.5+CO ₂+H2
contact method CAN
communication parameters 500k
measurement range CO2:0~10000ppm
H2:0~4%vol
PM:0~5mg/m³
response time T90≤15s
measurement accuracy CO2: ± 200ppm or ± 20% reading
@0~5000ppm&-20°C~60℃
H2:±(0.1%vol+10%)
PM:≤100ug/m³:±15ug/m³;
>100ug/m³:±15sreading
@-40℃~70℃
resolution CO₂/ H2:1ppm
PM:1μg/m³
*Please refer to the specification sheet for specific parameters