1、 Scope of application
The CJX1 (along with Siemens 3TF) series AC contactor is the latest product of the 1990s. The CJX1 AC contactor is used for AC 50Hz or 60Hz, with a rated insulation voltage of 690-1000V. Under the AC3 usage category, the rated working current is 9A-400A when the rated working voltage is 380V. Mainly used for long-distance connection and disconnection of circuits Suitable for controlling the start, stop, and reverse of AC motors,CJX1 AC contactorCompliant with standards such as IEC947, VDE0660, GB14048, etc.| Siemens AC contactor model | Taixi corresponds to the model of AC contactor |
| 3TF40/3TB40 | CJX1-9/22 |
| 3TF41/3TB41 | CJX1-12/22 |
| 3TF42/3TB42 | CJX1-16/22 |
| 3TF43/3TB43 | CJX1-22/22 |
| 3TF44/3TB44 | CJX1-32/22 |
| 3TF45 | CJX1-38/22 |
| 3TF46 | CJX1-45/22 |
| 3TF47 | CJX1-63/22 |
| 3TF48 | CJX1-75/22 |
| 3TF49 | CJX1-85/22 |
| 3TF50 | CJX1-110/22 |
| 3TF51 | CJX1-140/22 |
| 3TF52 | CJX1-170/22 |
| 3TF53 | CJX1-205/22 |
| 3TF54 | CJX1-250/22 |
| 3TF55 | CJX1-300/22 |
| 3TF56 | CJX1-400/22 |
| 3TF57 | CJX1-475/22 |
2、 Model and specifications

3、 Working conditions
3.1 Surrounding environmental temperature: -5 ℃~+40 ℃, with an average value not exceeding+35 ℃ within 24 hours.4、 Structural characteristics
The CJX1 AC contactor is a direct motion mechanism with double break point contacts, featuring three pairs of normally open main contacts and auxiliary contact combinations as shown in the table below. The CJX1 contactor contact support and armature adopt elastic locking and connection, eliminating weak links. The action mechanism is flexible, manual inspection is convenient, the structural design is compact, and it can prevent external debris and dust from falling into the moving parts. The wiring terminals have protective covers, and hands cannot directly contact live parts. The CJX1 contactor has small external dimensions and a small installation area. The installation method can be installed with guide rails or fastened with screws. Compared with other similar products, it has a higher operating frequency and control capacity. The product is safe and reliable, and is an internationally advanced contactor model.| model | Number of normally open contacts | Number of normally closed contacts | Hanging method |
| CJX1-9 CJX1-12 CJX1-9Z CJX1-12Z CJX1F-9 CJX1F-12 CJX1F-9Z CJX1F-12Z |
0 | 1 | The main body comes with its own |
| 1 | 0 | ||
| 1 | 4 | ||
| 2 | 3 | ||
| 3 | 2 | ||
| 4 | 1 | ||
| 5 | 0 | ||
| 4 | 0 | ||
| 3 | 1 | ||
| 2 | 2 | ||
| 1 | 3 | ||
| 0 | 4 | ||
| CJX1-16 CJX1-22 CJX1-16Z CJX1-22Z CJX1F-16 CJX1F-22 CJX1F-16Z CJX1F-22Z |
2 | 2 | The main body comes with its own |
| CJX1-32~475 CJX1F-32 CJX1F-38 |
2 | 2 | Side hung AX2 |
| 4 | 4 |
5、 Application and maintenance of CJX1 AC contactor
5.1 Inspection items during operation:6、 CJX1 AC contactor contact system:
The main and auxiliary contact materials are composed of silver alloy with superior electrical performance, which has a long service life and good contact reliability. The arc extinguishing chamber is enclosed and equipped with flame-retardant materials to prevent the arc from splashing outward. There is no arc extinguishing baffle for Ie ≤ 22A, and a metal baffle for Ie ≥ 32A to ensure the safety of personnel and nearby electrical appliances. The wiring screw adopts a new type of self lifting screw, and the tile shaped pad and screw are not separated, which can save wiring time.7、 CJX1 AC contactor magnetic system:
The electromagnetic system is reliable in operation, with low loss and noise, and has high mechanical strength. The wiring terminals of the wiring diagram are equipped with voltage specification labels, which are painted with specific colors for clear and eye-catching voltage levels. The wiring is convenient and can avoid coil burnout caused by incorrect voltage specifications.8、 Installation position of contactor:
The contactor must be installed on a vertical surface at the position shown in the diagram.
9、 Main parameters and technical performance
9.1 CJX1- □ AC contactor| model | Controllable motor power (kW) | Attraction coil power consumption | Working voltage range of coil | Rated operating frequency (1/h) | |||||||
| AC-3 | AC-4 | Communication (VA) | Communication (AC) | ||||||||
| 230/220V | 400/380V | 500V | 690/660V | 400/380V | 690/660V | maintain | pickup | AC-3 | AC-4 | ||
| CJX1-9 | 2.4 | 4 | 5.5 | 5.5 | 1.4 | 2.4 | 10 | 68 | (0.8~1.1)Us | 1200 | 300 |
| CJX1-12 | 3.3 | 5.5 | 7.5 | 7.5 | 1.9 | 3.3 | 10 | 68 | 1200 | 300 | |
| CJX1-16 | 4 | 7.5 | 10 | 11 | 3.5 | 6 | 10 | 68 | 1200 | 300 | |
| CJX1-22 | 6.1 | 11 | 11 | 11 | 4 | 6.6 | 10 | 68 | 1200 | 300 | |
| CJX1-32 | 8.5 | 15 | 21 | 23 | 7.5 | 13 | 10 | 69 | 600 | 300 | |
| CJX1-45 | 15 | 22 | 30 | 39 | 12.6/12 | 21.8/20.8 | 17 | 183 | 600 | 300 | |
| CJX1-63 | 18.5 | 30 | 41 | 55 | 14.7/14 | 25.4/24.3 | 17 | 183 | 600 | 300 | |
| CJX1-75 | 22 | 37 | 50 | 67 | 17.9/17 | 30.9/29.5 | 32 | 330 | 600 | 300 | |
| CJX1-85 | 26 | 45 | 59 | 67 | 22/21 | 38/36 | 32 | 330 | 600 | 300 | |
| CJX1-110 | 37 | 55 | 76 | 100 | 28.4/27 | 49/46.9 | 39 | 550 | 600 | 300 | |
| CJX1-140 | 43 | 75 | 98 | 100 | 36/35 | 63/60 | 39 | 550 | 600 | 300 | |
| CJX1-170 | 55 | 90 | 118 | 156 | 40/38 | 69/66 | 58 | 910 | 300 | 300 | |
| CJX1-205 | 64 | 110 | 145 | 156 | 52/50 | 90/86 | 58 | 910 | 300 | 300 | |
| CJX1-250 | 78 | 132 | 178 | 235 | 61/58 | 105/100 | 84 | 1430 | 300 | 300 | |
| CJX1-300 | 93 | 160 | 210 | 235 | 69/66 | 119/114 | 84 | 1430 | 300 | 300 | |
| CJX1-400 | 125 | 200 | 284 | 375 | 85/81 | 147/140 | 115 | 2450 | 300 | 300 | |
| CJX1-475 | 144 | 250 | 329 | 375 | 85/81 | 147/140 | 115 | 2450 | 300 | 300 | |
| model | Rated insulation voltage (V) |
mechanical life (times) |
Rated working current (A) 380V |
electrical life |
Promise freedom air fever Current (A) |
Auxiliary contact current Ie (A) | Assisted Touch Head agreement Free Space Gas heating Current (A) |
|||
| AC-15 | DC-13 | |||||||||
| AC-3 | AC-4 | AC-3 | AC-4 | 380/220V | 110/220V | |||||
| CJX1-9 | 660 | 1000000 | 9 | 3.3 | 1.2 | 0.2 | 20 | 0.95 | 0.15 | 10 |
| CJX1-12 | 660 | 12 | 4.3 | 1.2 | 0.2 | 20 | ||||
| CJX1-16 | 660 | 16 | 7.7 | 1.2 | 0.2 | 31.5 | ||||
| CJX1-22 | 660 | 22 | 8.5 | 1.0 | 0.2 | 31.5 | ||||
| CJX1-32 | 660 | 32 | 15.6 | 1.0 | 0.2 | 40 | ||||
| CJX1-45 | 1000 | 45 | 24 | 1.0 | 0.2 | 63 | ||||
| CJX1-63 | 1000 | 63 | 28 | 1.0 | 0.2 | 80 | ||||
| CJX1-75 | 1000 | 75 | 34 | 1.0 | 0.2 | 100 | ||||
| CJX1-85 | 1000 | 85 | 42 | 1.0 | 0.2 | 100 | ||||
| CJX1-110 | 1000 | 110 | 54 | 1.0 | 0.2 | 160 | ||||
| CJX1-140 | 1000 | 140 | 68 | 1.0 | 0.2 | 160 | ||||
| CJX1-170 | 1000 | 170 | 75 | 1.0 | 0.2 | 210 | ||||
| CJX1-205 | 1000 | 205 | 96 | 1.0 | 0.2 | 210 | ||||
| CJX1-250 | 1000 | 250 | 110 | 1.0 | 0.2 | 300 | ||||
| CJX1-300 | 1000 | 300 | 125 | 1.0 | 0.2 | 300 | ||||
| CJX1-400 | 1000 | 400 | 150 | 1.0 | 0.2 | 400 | ||||
| CJX1-475 | 1000 | 475 | 150 | 1.0 | 0.2 | 475 | ||||
| model | Controllable motor power (kW) | Attraction coil power consumption | Working voltage range of coil | Rated operating frequency (1/h) | |||||||
| AC-3 | AC-4 | Communication (VA) | Communication (AC) | ||||||||
| 230/220V | 400/380V | 500V | 690/660V | 400/380V | 690/660V | maintain | pickup | AC-3 | AC-4 | ||
| CJX1F-9 | 2.4 | 4 | 5.5 | 5.5 | 1.48/1.4 | 2.54/2.4 | 10 | 68 | (0.8~1.1)Us | 1200 | 300 |
| CJX1F-12 | 3.3 | 5.5 | 7.5 | 7.5 | 2/1.9 | 3.45/3.3 | 10 | 68 | 1200 | ||
| CJX1F-16 | 4 | 7.5 | 10 | 11 | 3.5 | 6 | 10 | 68 | 1200 | ||
| CJX1F-22 | 6.1 | 11 | 11 | 11 | 4 | 6.6 | 10 | 68 | 1200 | ||
| CJX1F-32 | 8.5 | 15 | 21 | 23 | 7.5 | 13 | 12.1 | 101 | 600 | ||
| CJX1F-38 | 11 | 18.5 | 25 | 23 | 9 | 15.5 | 12.1 | 101 | 600 | ||
| model | Rated insulation voltage (V) |
mechanical life (times) |
Rated working current (A) 380V |
electrical life |
Promise freedom air fever Current (A) |
Auxiliary contact current Ie (A) | Assisted Touch Head agreement Free Space Gas heating Current (A) |
|||
| AC-15 | DC-13 | |||||||||
| AC-3 | AC-4 | AC-3 | AC-4 | 380/220V | 110/220V | |||||
| CJX1F-9 | 660 | 1000000 | 9 | 3.3 | 1.2 | 0.2 | 20 | 0.95 | 0.15 | 10 |
| CJX1F-12 | 12 | 4.3 | 1.2 | 0.2 | 20 | |||||
| CJX1F-16 | 16 | 7.7 | 1.2 | 0.2 | 31.5 | |||||
| CJX1F-22 | 22 | 8.5 | 1.0 | 0.2 | 31.5 | |||||
| CJX1F-32 | 32 | 15.6 | 1.0 | 0.2 | 40 | |||||
| CJX1F-38 | 38 | 18.5 | 1.0 | 0.2 | 55 | |||||
| model | Controllable motor power (kW) | Attraction coil power consumption | Working voltage range of coil | Rated operating frequency (1/h) | |||||||
| AC-3 | AC-4 | Communication (VA) | Communication (AC) | ||||||||
| 230/220V | 400/380V | 500V | 690/660V | 400/380V | 690/660V | maintain | pickup | AC-3 | AC-4 | ||
| CJX1-9/Z | 2.4 | 4 | 5.5 | 5.5 | 1.4 | 2.4 | 6.5 | 6.5 | (0.8~1.1)Us | 1200 | 300 |
| CJX1-12/Z | 3.3 | 5.5 | 7.5 | 7.5 | 1.9 | 3.3 | |||||
| CJX1-16/Z | 4 | 7.5 | 10 | 11 | 3.5 | 6 | |||||
| CJX1-22/Z | 6.1 | 11 | 11 | 11 | 4 | 6.6 | |||||
| model | Rated insulation voltage (V) |
mechanical life (times) |
Rated working current (A) 380V |
electrical life |
Promise freedom air fever Current (A) |
Auxiliary contact current Ie (A) | Assisted Touch Head agreement Free Space Gas heating Current (A) |
|||
| AC-15 | DC-13 | |||||||||
| AC-3 | AC-4 | AC-3 | AC-4 | 380/220V | 110/220V | |||||
| CJX1-9/Z | 660 | 1000000 | 9 | 3.3 | 1.2 | 0.2 | 20 | 0.95 | 0.15 | 10 |
| CJX1-12/Z | 12 | 4.3 | 1.2 | 0.2 | 20 | |||||
| CJX1-16/Z | 16 | 7.7 | 1.2 | 0.2 | 31.5 | |||||
| CJX1-22/Z | 22 | 8.5 | 1.0 | 0.2 | 31.5 | |||||
| model | Controllable motor power (kW) | Attraction coil power consumption | Working voltage range of coil | Rated operating frequency (1/h) | |||||||
| AC-3 | AC-4 | Communication (VA) | Communication (AC) | ||||||||
| 230/220V | 400/380V | 500V | 690/660V | 400/380V | 690/660V | maintain | pickup | AC-3 | AC-4 | ||
| CJX1F-9/Z | 2.4 | 4 | 5.5 | 5.5 | 1.48/1.14 | 2.54/2.4 | 6.5 | 6.5 | (0.8~1.1)Us | 1200 | 300 |
| CJX1F-12/Z | 3.3 | 5.5 | 7.5 | 7.5 | 2/1.9 | 3.45/3.3 | |||||
| CJX1F-16/Z | 4 | 7.5 | 10 | 11 | 3.5 | 6 | |||||
| CJX1F-22/Z | 6.1 | 11 | 11 | 11 | 4 | 6.6 | |||||
| model | Rated insulation voltage (V) |
mechanical life (times) |
Rated working current (A) 380V |
electrical life |
Promise freedom air fever Current (A) |
Auxiliary contact current Ie (A) | Assisted Touch Head agreement Free Space Gas heating Current (A) |
|||
| AC-15 | DC-13 | |||||||||
| AC-3 | AC-4 | AC-3 | AC-4 | 380/220V | 110/220V | |||||
| CJX1F-9/Z | 660 | 1000000 | 9 | 3.3 | 1.2 | 0.2 | 20 | 0.95 | 0.15 | 10 |
| CJX1F-12/Z | 12 | 4.3 | 1.2 | 0.2 | 20 | |||||
| CJX1F-16/Z | 16 | 7.7 | 1.2 | 0.2 | 31.5 | |||||
| CJX1F-22/Z | 22 | 8.5 | 1.0 | 0.2 | 31.5 | |||||
10、 Appearance and installation dimensions
10.1 CJX1-9~140 AC contactor| model | A max | b | C max | d | E max | F | Φ |
| CJX1-9/22 | 78 | 60±0.6 | 45 | 35±0.5 | 102 | 8 | 4.8 |
| CJX1-12/22 | 78 | 60±0.6 | 45 | 35±0.5 | 102 | 8 | 4.8 |
| CJX1-16/22 | 89 | 75±0.6 | 46 | 35±0.5 | 116 | 8.5 | 4.8 |
| CJX1-22/22 | 89 | 75±0.6 | 46 | 35±0.5 | 116 | 8.5 | 4.8 |
| CJX1-32/22 | 90 | 75±0.6 | 74 | 50±0.5 | 109 | 8 | 5 |
| CJX1-45/22 | 120 | 100±0.7 | 92 | 70±0.6 | 125 | 12 | 5 |
| CJX1-63/22 | 120 | 100±0.7 | 92 | 70±0.6 | 125 | 12 | 5 |
| CJX1-75/22 | 135 | 110±0.7 | 105 | 80±0.6 | 145 | 12 | 5.5 |
| CJX1-85/22 | 135 | 110±0.7 | 105 | 80±0.6 | 145 | 12 | 5.5 |
| CJX1-110/22 | 158 | 130±0.8 | 125 | 100±0.7 | 155 | 12 | 6.5 |
| CJX1-140/22 | 158 | 130±0.8 | 125 | 100±0.7 | 155 | 12 | 6.5 |
| model | A1 max | A2 max | a3 | B1 max | b2 | C1 max | M | e1 | f1 | g | d1 | d2 | Φg1 |
| CJX1-170 | 140 | 165 | 110±0.7 | 185 | 160±0.8 | 190 | 8 | 154 | 115 | 48 | 20 | 42 | 7 |
| CJX1-205 | 140 | 165 | 110±0.7 | 185 | 160±0.8 | 190 | 10 | 154 | 115 | 48 | 20 | 42 | 7 |
| CJX1-250 | 145 | 168 | 120±0.7 | 200 | 180±0.8 | 198 | 10 | 168 | 133 | 58 | 25 | 48 | 9 |
| CJX1-300 | 145 | 168 | 120±0.7 | 200 | 180±0.8 | 198 | 10 | 168 | 135 | 58 | 25 | 48 | 9 |
| CJX1-400 | 160 | 183 | 130±0.8 | 200 | 180±0.8 | 222 | 10 | 178 | 150 | 65 | 25 | 48 | 9 |
| CJX1-475 | 160 | 183 | 130±0.8 | 200 | 180±0.8 | 222 | 10 | 178 | 150 | 65 | 25 | 48 | 9 |
| model | A max | b | C max | d | E max | F | Φ |
| CJX1F-9/22 | 78 | 60±0.6 | 45 | 35±0.5 | 102 | 8 | 4.8 |
| CJX1F-12/22 | 78 | 60±0.6 | 45 | 102 | |||
| CJX1F-16/22 | 89 | 75±0.6 | 46 | 116 | |||
| CJX1F-22/22 | 89 | 75±0.6 | 46 | 116 | |||
| CJX1F-32/22 | 104 | 75±0.6 | 83 | 109 | |||
| CJX1F-38/22 | 104 | 75±0.7 | 83 | 109 |
| model | A max | b | C max | d | E max | F | Φ |
| CJX1-9/22Z | 78 | 60±0.6 | 46 | 35±0.5 | 142 | 8 | 4.8 |
| CJX1-12/22Z | 78 | 60±0.6 | 142 | ||||
| CJX1-16/22Z | 89 | 75±0.6 | 148 | ||||
| CJX1-22/22Z | 89 | 75±0.6 | 148 |
| model | A max | b | C max | d | E max | F | Φ |
| CJX1F-9/22Z | 78 | 60±0.6 | 46 | 35±0.5 | 142 | 8 | 4.8 |
| CJX1F-12/22Z | 78 | 60±0.6 | 142 | ||||
| CJX1F-16/22Z | 89 | 75±0.6 | 148 | ||||
| CJX1F-22/22Z | 89 | 75±0.6 | 148 |




11、 Ordering Notice
When ordering a contactor, the complete product model, name, frequency, voltage, and quantity of the suction coil must be specified.