1、 Scope of application
DZ15LE residual current circuit breakerIt is a neutral to ground leakage protection device suitable for circuits with AC 50Hz, rated voltage 380V, and rated current up to 63A (100A). It is used for leakage protection and can also be used to prevent fire hazards caused by grounding fault currents due to equipment insulation damage. And it can be used to protect the circuit and motor from overload and short circuit, and can also be used for infrequent switching of the circuit and infrequent starting of the motor. The rated leakage action value of the residual current circuit breaker can be adjusted by switching according to actual usage requirements.2、 DZ15LE leakage circuit breaker model and specifications

3、 Normal working conditions and installation conditions of DZ15LE residual current circuit breaker
The altitude of the installation location shall not exceed 2000 meters.4、 Main technical parameters and performance of DZ15 residual current circuit breaker
| model | rated voltage Un(V) |
Shell level Rated current (A) |
number of poles | Rated current (A) |
Rated limit short Road analysis ability Icu(kA) |
Rated operation short Road analysis ability Ics(kA) |
Rated residual connection Switching ability IΔm(kA) |
Rated residual action current I△n(mA) |
Rated residual not action current I△no(mA) |
Arcing distance |
| DZ15LE-40 | 220 | 40 | 2 | 6, 10,16, 20,25, 32,40 |
3 | 1.5 | 1.0 | 15 | 8 | ≤50 |
| 30 | 15 | |||||||||
| 50 | 25 | |||||||||
| 380 | 3 | 75 | 40 | |||||||
| 100 | 50 | |||||||||
| 4 | 200 | 100 | ||||||||
| 300 | 150 | |||||||||
| DZ15LE-100 | 220 | 100 | 2 | 10,16, 20,25, 32,40, 50,63, 80,100 |
5 | 2.5 | 1.5 | 30 | 15 | ≤70 |
| 50 | 25 | |||||||||
| 75 | 40 | |||||||||
| 380 | 3 | 100 | 50 | |||||||
| 200 | 100 | |||||||||
| 4 | 300 | 150 | ||||||||
| 500 | 250 |
| Residual current | I△n | 2I△n | 5I△n *a | 10I△n*b |
| Maximum interruption time (s) | 0.3 | 0.15 | 0.04 | 0.04 |
| a. For residual current circuit breakers with I △ n ≤ 0.03, 5I △ n can be replaced with 0.25A. | ||||
| b. When using 0.25A according to Note A, then 10I △ n is 0.5A. | ||||
| Delay time (s) | Maximum at I △ n Breaking time (S) |
2I△n | Maximum at 5I △ n Breaking time (S) |
|
| Maximum non driving time (S) | Maximum interruption time (S) | |||
| 0.1 | 0.3 | 0.08 | 0.27 | 0.14 |
| 0.2 | 0.4 | 0.18 | 0.37 | 0.24 |
| 0.3 | 0.5 | 0.28 | 0.47 | 0.34 |
| 0.4 | 0.6 | 0.38 | 0.57 | 0.44 |
| 0.5 | 0.7 | 0.48 | 0.67 | 0.54 |
| 1 | 1.2 | 0.98 | 1.17 | 1.04 |
| Protection type | On load operating conditions | Shell level Rated current (A) |
Number of operation cycles | Hourly operation Number of cycles |
||||
| put through | breaking | cosφ | On load | no-load | Total number of times | |||
| Used for motor protection | Un 6In | 0.17Un 6In | 0.35 | 40, 100 | 1500 | 8500 | 10000 | 120 times |
| For distribution lines | Un In | Un In | 0.8 | 40, 100 | 1500 | 8500 | 10000 | 120 times |
| ambient air temperature | Test current/rated current | Test time | Initial state | |
| In>63A | In≤63A | |||
| 1.05 | Not tripped within 2 hours | Not tripped within 1 hour | Cold state begins | |
| +30±2℃ | 1.30 | Release within 2 hours | Release within 1 hour | Hot state begins |
| ambient air temperature | Test current/rated current | Test time | Initial state |
| +20±2℃ | 1.05 | Not tripped within 2 hours | Cold state begins |
| 1.20 | Release within 2 hours | Hot state begins | |
| -5±2℃ | 1.05 | Not tripped within 2 hours | Cold state begins |
| 1.30 | Release within 2 hours | Hot state begins | |
| +40±2℃ | 1.00 | Not tripped within 2 hours | Cold state begins |
| 1.20 | Release within 2 hours | Hot state begins |
5、 Structure and Working Principle of DZ15LE Circuit Breaker
DZ15LE residual current circuit breakerThe electronic residual current circuit breaker is mainly composed of zero sequence current transformers, electronically controlled residual current release devices, and circuit breakers with overload and short-circuit protection. All components are housed in a plastic casing.6、 Appearance and installation dimensions
| model | number of poles | External dimensions | Installation size | |||||
| A | B | C | D | a | b | Mounting Hole | ||
| DZ15L-40 | 3 | 78 | 194 | 88 | 73.5 | 25 | 180 | 4-5 |
| 4 | 103 | 194 | 88 | 73.5 | 50 | 180 | 4-5 | |
| DZ15L-63 | 3 | 96 | 227 | 95 | 80 | 30 | 210 | 4-7 |
| 4 | 126 | 227 | 95 | 80 | 60 | 210 | 4-7 | |
| DZ15LE-100 | 3 | 96 | 227 | 95 | 80 | 30 | 210 | 4-7 |
| 4 | 126 | 227 | 95 | 80 | 60 | 210 | 4-7 | |

7、 Ordering Notice
When placing an order, please indicate the following points:
Product model and name: such asDZ15LEMCCB
Instantaneous tripping rated current: such as 315A.
The accessory name, specification, and combination code of the circuit breaker should indicate the voltage value of the working voltage (or control power supply voltage) when using undervoltage release and shunt release;
Polar number: 3P
Order quantity: such as 380 pieces.
Example of ordering:DZ15L-400/3300,4P,AC380V,250A, 3500 pieces.