Welcome Customer !

Membership

Help

Qingdao Juchuang Environmental Protection Group Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Qingdao Juchuang Environmental Protection Group Co., Ltd

  • E-mail

    340570972@qq.com

  • Phone

    13127012891

  • Address

    15th Floor, Building 3, No. 266 Jiushui East Road, Licang District, Qingdao City, Shandong Province

Contact Now

Defender dry gas flowmeter

NegotiableUpdate on 01/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Defender Dry Gas Flow Meter $r $nDefender510/520/530+is a new generation of dry gas flow meter, which is a primary flow meter. Can be used in the fields of industrial hygiene, environmental protection, and various laboratories. It adopts the principle of dry piston motion, and multiple readings can be generated with one button press. The 520 model has added the ability to simultaneously test temperature and pressure compared to the 510. Defender530+, the combined model of Defender530 and Definer220.

Product Details

Defender dry gas flowmeter

  • 1、 Product Introduction:
    Defender510/520/530+is a new generation of dry gas flowmeter, which is a primary flowmeter. Can be used in the fields of industrial hygiene, environmental protection, and various laboratories. It adopts the principle of dry piston motion, and multiple readings can be generated with one button press. The 520 model has added the ability to simultaneously test temperature and pressure compared to the 510. Defender530+, the combined model of Defender530 and Definer220.


    2、 Product parameters:


    model

    flow range


    precision






    Record temperature and pressure



    standard

    volume






    Defender 510-L

    5 mL- 500 mL/min


    1%

    none

    Defender 510-M

    50 mL- 5,000 mL/min


    1%

    none

    Defender 510-H

    300 mL- 30,000 mL/min


    1%

    none






    Defender 520-L

    5 mL- 500 mL/min


    %

    have

    Defender 520-M

    50 mL- 5,000 mL/min


    1%

    have

    Defender 520-H

    300 mL- 30,000 mL/min


    1%

    have






    Defender 530+L

    5 mL- 500 mL/min

    1%

    0.75%

    have

    Defender 530+M

    50 mL- 5,000 mL/min

    1%

    0.75%

    have

    Defender 530+H

    300 mL- 30,000 mL/min

    1%

    0.75%

    have


    3、 Product features:

    1. First level standard, NIST traceable, units displayed: mL, L, cc, cfm Accuracy: ± 1%, continuous automatic measurement, quick and easy adjustment of air sampler flow rate
    2. Automatically calculate multi-point average values, up to 100 data points for dry graphite piston design
    3. No need for soap solution, when measuring and quickly stopping use
    4. Automatic shutdown and power-saving function within 5 minutes, saving battery power
    5. Both positive pressure intake and negative pressure exhaust can be measured, and calibration data results can be downloaded by connecting to a PC
    6. It can be adjusted to the volume flow rate under standard conditions, with self testing internal leakage Defender510/520/530+different models to meet different user needs.
    7. Technical requirements: Reading time per time: 1-15 seconds
    8. Reading mode: (choose the average of 1 to 100 measurements) Single (manual), continuous or burst mode
    9. Gas compatibility: non corrosive gas, non condensing gas, humidity less than 70%
    1. Flow mode: compression or suction. Measurement unit: integrated type
    11. AC/DC converter/charger: 12V DC,>250ma, 2.5mm center position
    12. Battery System Battery Type: 6V rechargeable sealed lead-acid battery, typical working time 6-8 hours Battery operating time (5 times/minute): background light on for 3 hours, background light off for 8 hours Press in or suction Attachment: hose
    Operating pressure: 15 PSI

    13. Display: Backlit graphic LCD display data port (using optimization software): RS-232 serial data cable (using optimization software): 1 meter Defender calibrator to computer serial port size (H x W x D): 140x150x75mm
    Optional dedicated dust sampler conversion head for calibrating dust sampler flow rate