Overview
The parameters of the double door sterilization oven gradually decrease with the decrease of water vapor, and fresh filtered air is intermittently replenished. The inside of the box is in a slightly positive pressure state, and the constant temperature ends. The process control is completed. Turn on the air supply or (inlet) forced cooling, the automatic butterfly valve enters the closed state, and the sound and light prompt opens the door to release the bottle.
Product Details

Double door sterilization oven parametersWorking Principle:
Place the drying tray, bottle, or cart filled with materials into the box, start the PLC programmable control system, and the internal circulation fan will work, heat up, and the butterfly valve will open simultaneously. The drying box will quickly heat up. Under the action of the internal circulation fan, hot and dry air enters the box through a high-temperature resistant and efficient filter. Under the action of the fine adjustment plate, a uniform distribution of air is formed and transmitted into the box. The dry air absorbs the moisture on the surface of the bottle (material, item) and enters the heating channel for evaporation and discharge. The dry air flows directionally under the action of the fan, and the water vapor is discharged.

Double door sterilization oven parametersTechnical Specifications

Project model

DMH - 1

DMH - 2

DMH - 3

DMH - 4

studio dimensions

Width x Depth x Height?

500×600×750

800×800×1000

1000×1000×1200

1000×1200×1500

Overall dimensions

Width x Depth x Height??

1250×900×1700

1550×1100×1950

1750×1300×2150

1750×1500×2450

Heating power??

6

9

12

18

Circulating fan power

0.75

1.1

1.1

1.1

Supplement fan power

0.03

0.45

0.45

0.45

Design temperature range

Room temperature~260

cleanliness level

Level 100

As the water vapor gradually decreases and fresh filtered air is intermittently replenished, the box is in a slightly positive pressure state, the constant temperature ends, and the process control is completed. Turn on the air supply or (inlet) forced cooling, the automatic butterfly valve enters the closed state, and the sound and light prompt opens the door to release the bottle.