BBS-600 typeClosed flash point tester
Under specified conditions, when the oil is heated to a certain temperature, the mixture of oil vapor and surrounding air will ignite upon contact with the flame. The lowest flash temperature is called the flash point value of the oil.
BBS-600 Type FullAutomatic closed flash point testerIt is manufactured in accordance with the requirements of the national standards GB/T261-2008 "Determination of Flash Point by Binsky Martin Closed Cup Method", SH/T0315, ISO2719-88, etc., and is widely used in departments such as petroleum, chemical, power, environmental protection, railway, and scientific research.
BBS-600 typeClosed flash point tester
Advantages and Characteristics
1 color Chinese LCD screen display, controlled by high-speed signal processor, high-precision analog/digital conversion circuit
2. Adopting adaptive PID control algorithm to automatically adjust the heating curve according to standard requirements
3. Automatic completion of air supply, stirring, ignition, detection, alarm, cooling, and printing instruments
The entire testing process includes automatic detection, lid opening, ignition, alarm, cooling, printing, etc
5 differential detection, automatic correction of system deviation, automatic stop detection and alarm for temperature exceeding the limit
Equipped with parameter prompt functions such as test date and time
7 data storage functions, capable of storing 200 results
BBS-600 typeClosed flash point tester
Technical Parameter
Display mode: |
320X240 dot matrix Chinese LCD screen |
Measurement method: |
Thermocouple differential detection formula |
Measurement range: |
Room temperature -350 ℃ |
resolving power: |
0.1℃ |
Repeatability: |
National standard: When the flash point value is<104 ℃, the allowable deviation is ± 1 ℃, and when the flash point value is ≥ 104 ℃, the allowable deviation is ± 2 ℃ |
printer: |
High speed thermal printer, 56mm paper width |
Temperature detection: |
Imported platinum resistor (Pt100 Ω) |
Ignition method: |
Ignite with gas source |
Self checking function: |
Automatic diagnosis of instrument faults |
Cooling method: |
Forced air cooling |
Power consumption: |
<550W |
Usage environment: |
Temperature 10 ℃ -45 ℃, humidity 30-80% |
Power supply: |
AC220V±10% |
External dimensions: |
397*305*240 mm |
Weight: |
About 15KG
|